GENERAL DESCRIPTION
The
The
TECHNICAL SPECIFICATIONS
Ordering | Product | Input | Rated | Additional | Dimensions |
Information | Description | Frequency | Output | Output | & Weight |
|
|
|
|
|
|
K1410 | Multiprocess | 60 Hz | 700 Amps | 600 Amps | 27.50 (1) x 22.25 x 38 in |
| DC Power |
| 44 Volts | 44 Volts | (698 x 565 x 965 mm) |
| Source |
|
|
| 725 lbs |
|
|
| 100% Duty | 100% Duty | |
|
|
| Cycle | Cycle | (330 kg) |
|
|
|
|
|
|
INPUT SPECIFICATIONS
|
|
|
|
|
|
|
|
Input | Input Currents - 44 V Output |
| Idle | Idle | |||
Voltage |
| @ 600 A | @ 700 A | @ 750 A |
| Current | Power (2) |
|
|
|
|
|
|
|
|
208 V | 130 A | 146 A | 153 A |
| 12 A | 1.5 kW | |
|
|
|
|
|
|
|
|
230 V | 117 A | 132 A | 139 A |
| 11 A | 1.5 kW | |
|
|
|
|
|
|
|
|
460 V | 59 A | 66 A | 69 A |
| 6 A | 1.5 kW | |
|
|
|
|
|
|
|
|
575 V | 47 A | 53 A | 56 A |
| 5 A | 1.5 kW | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OUTPUT SPECIFICATIONS
Rated Output | Additional |
|
|
|
|
|
(DC) | Output Ratings | Auxiliary | Open | Output | Efficiency | |
At 40°C | At 60°C | Outputs | Circuit | Current | Power Factor (2) | |
Ambient | Ambient |
| Voltage | Range |
|
|
Temperature | Temperature |
|
|
|
|
|
|
|
|
|
|
| |
700 Amps | 600 Amps | Two 115 Volts AC | GMAW | @ 600A - 44V load: | ||
44 Volts | 44 Volts | 15 Amps | FCAW |
| Eff= 65% | PF= .88 |
100% | 100% |
| SAW |
|
|
|
Duty Cycle | Duty Cycle | One 42 Volts AC | SMAW |
| @ 700A - 44V load: | |
750 Amps | 750 Amps | 10 Amps |
|
| Eff= 66% | PF= .90 |
|
|
|
|
| ||
44 Volts | 44 Volts |
|
|
| @ 750A - 44V load: | |
60% | 35% |
|
|
| ||
|
|
| ||||
|
|
| Eff= 67% | PF= .90 | ||
Duty Cycle | Duty Cycle |
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
|
|
(1)Overall height 30.75 in (781 mm) including lift bale.
(2)Loaded readings are taken with a full auxiliary load. No load ratings are taken without auxiliary loads.
–7 –