FCAW (Flux-Cored) Operation

Properly connect a wire feeder control cable to either the terminal strip or to the Wire Feeder Receptacle.

If welding electrode positive, connect the electrode to the “+” output studs, and connect the work cable to the “-” studs labeled “GMAW, FCAW”. If welding electrode negative, reverse the connections. Do not make any connections to the left hand pair of output studs.

Set the control panel switches as follows:

------------------------------------------------------------------------

Mode: FCAW

------------------------------------------------------------------------

Output Local or Remote (See “Output Control

Control: Switch”)

------------------------------------------------------------------------

LN-9/NA-5:Off, unless an LN-9 or NA-5 is being used.

------------------------------------------------------------------------

Wire Feeder Set to match the electrode polarity.

Voltmeter:

------------------------------------------------------------------------

Output

Terminals: Remote

------------------------------------------------------------------------

If using Local output control, preset the desired welding voltage using the Output potentiometer and the voltmeter. If using Remote Output control, preset the welding voltage using a remote control, or with the voltage control on the wire feeder. If using an LN-9 and NA-5, see “operation with LN-9 or NA-5 Wire Feeder” section.

Set up the wire feeder according to the wire feeder instruction manual.

When the gun trigger is pulled (or the weld sequence is started) and an arc is struck, the voltmeter will display the welding voltage present at the output studs of the DC-650 PRO, and the ammeter will display the output current.

SAW (Submerged Arc) Operation

Properly connect a wire feeder control cable to either the terminal strip or to the Wire Feeder Receptacle.

If welding electrode positive, connect the electrode cable to the “+” output studs, and connect the work cable to the “-” studs labeled “SMAW,SAW”. If welding electrode negative, reverse the connections. Do not make any connections to the center pair of output studs.

Set the control panel switches as follows:

------------------------------------------------------------------------

Mode: SAW

------------------------------------------------------------------------

Output Local or Remote (See “Output Control

Control: Switch”)

------------------------------------------------------------------------

LN-9/NA-5:Off, unless an LN-9 or NA-5 is being used.

------------------------------------------------------------------------

Wire Feeder Set to match the electrode polarity.

Voltmeter:

------------------------------------------------------------------------

Output

Terminals: Remote

------------------------------------------------------------------------

If using Local output control, preset the desired welding voltage using the Output Potentiometer and the voltmeter. If using Remote output control, preset the welding voltage using a remote control, or with the voltage control on the wire feed unit. If using an LN-9 or NA-5, see “Operation with LN-9 or NA-5 Wire Feeder “ section.

Set up the wire feed unit according to the wire feeder instruction manual.

When the gun trigger is pulled (or the weld sequence is started) and an arc is struck, the voltmeter will display the welding voltage present at the output studs of the DC-650 PRO, and the ammeter will display the output current.

16

Image 16
Contents DC-650 PRO Electric Shock can kill ARC Welding can be hazardousCylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Thank You Please Examine Carton and Equipment For Damage ImmediatelyTechnical Specifications Input SpecificationsOutput Specifications General DescriptionInstallation Minimizing Problems Due to High FrequencyElectric Shock can kill LocationPage Recommended Input Wire and Fuse Sizes Output Connections Wire Feeder Control Cable Connections DC-650 PROExplanation of Controls Connection to Auxiliary PowerConnection of a K775 Remote Output Control Mode Switch Wire Feeder Voltmeter SwitchOutput Terminals Switch Power Switch and Pilot LightMode Gmaw Control SwitchOperating Instructions Voltmeter Output Terminals RemoteMode Fcaw Mode SAWFcaw Flux-Cored Operation SAW Submerged Arc OperationOperation with an LN-9 or NA-5 Wire Feeder Smaw Stick OperationInstallation with an NA-3 Protective CircuitryAC-A Arc Gouging Operation Thermostatic ProtectionTroubleshooting Routine MaintenancePower Source Troubleshooting Overload ProtectionTrouble Cause What to do Check & replace if defective Troubleshooting Accessory Troubleshooting Gmaw modeTroubleshooting Page Meter PC Board Protection PC BoardSnubber PC Board Output Bypass PC BoardsDC-650 PRO Wiring Diagram Dimension Prints DC-650 PRO with a K817 Undercarriage DC-650 PRO DC-750 223Page How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung