GENERATOR MAINTENANCE

Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that includes excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the generator head.

Ground Fault Circuit Interrupter (GFCI receptacle)

MONTHLY: For maximum protection against electrical shock the GFCI should be tested monthly.

To test:

1.Depress the TEST button. The RESET button should extend. If the RESET button does not extend, notify a Porter-Cable Authorized Service Center.

2.To restore power, depress the RESET button firmly into the GFCI unit until an audible click is heard. If reset properly, the RESET button is flush with the surface of the test button. When the button stays in, the power is ON.

STORAGE

If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage.

Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances.

Engine Preparation

1.Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.

2.Run engine at least 5 minutes after adding stabi- lizer to allow it to enter the fuel system.

3.Next shut off engine.

4.Disconnect the spark plug wire and remove the spark plug.

5.Add one teaspoon of oil through the spark plug hole.

6.Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber.

7.Replace the spark plug, but do not connect the spark plug wire.

NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and carburetor to prevent gum deposits from forming on these parts and causing possible malfunction of the engine.

Generator

Clean the generator as outlined in the Maintenance Section on this manual.

Check that cooling air slots and openings on generator are open and unobstructed.

15 — ENG

Image 15
Contents Instruction Manual Generators CH350CS SpecificationThis Warranty is not Transferable and does not Cover WarrantyRisk of Electrocution and Fire Safety Guidelines DefinitionsImportant Safety Instructions Hazard What could Happen HOW to Prevent ITWet, icy, or flooded conditions Operation of generator in rainArea Risk of FireDo not Operate Unit Doors or in ANY ConfinedRisk of Breathing Inhalation Hazard Risk of Unsafe Operation Listed voltage surge protecGenerator Risk of HOT Surfaces Risk of Moving PartsRisk from Lifting Grounding the Generator AssemblyExtension Cord Wire Gauge Chart Length Remove Generator from CartonOperation Before Start UP Connecting Electrical Loads To Start the EngineStopping Engine Customer Responsibilities Table MaintenanceGeneral Recommendations Engine Maintenance Maintenance TaskGenerator Maintenance StorageTo test Running Watts Starting Watts Wattage CalculationsVolts X Amp = Watts Volts x 10 amps = 1200 watts Starting Wattage RequirementsAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorProblem Cause Correction Troubleshooting GuideGenerator Quick Facts

CH350CS, H450CS, CH350CS, H650CS, CH350CS, H650CS specifications

The Porter-Cable H450CS, CH350CS, and H650CS are part of a renowned line of power tools designed for heavy-duty performance, catering to both professionals and DIY enthusiasts. These models deliver exceptional power and versatility, making them suitable for a diverse range of applications in woodworking, construction, and maintenance tasks.

The H450CS is an exceptional tool known for its lightweight design and robust performance. Featuring a powerful motor, it can handle various materials with ease, making it ideal for cutting, sanding, and shaping. The model’s ergonomic handle ensures comfort during extended use, while the quick-release blade mechanism allows for fast and easy blade changes. The H450CS also comes equipped with adjustable speed settings, allowing users to customize performance for different tasks, enhancing precision and control.

The CH350CS stands out with its impressive compactness and rugged construction. This model is designed for users who need a portable solution without compromising on power. The CH350CS features high-grade materials that ensure longevity and reliability, while its variable speed control provides adaptability for various applications. This tool excels in precise cuts and fine detail work, making it a favorite among carpenters and hobbyists alike. Additionally, it includes integrated dust management features, which enhance the user experience by minimizing cleanup.

The H650CS reflects the advanced technology that Porter-Cable is known for. This model includes innovative features such as an advanced motor cooling system that prolongs tool life by preventing overheating during extended use. Its heavy-duty construction makes it capable of handling tough jobs, while the user-friendly interface ensures that both beginners and experienced users can operate it effortlessly. The H650CS also incorporates safety features, including blade guards and anti-kickback mechanisms, providing added confidence for users during operation.

Overall, the Porter-Cable H450CS, CH350CS, and H650CS represent a top-tier selection of power tools. Their combination of advanced technologies, user-friendly designs, and high-quality construction makes them indispensable assets for professionals and DIY enthusiasts alike. Whether for intricate projects or substantial construction tasks, these models offer reliability and efficiency, positioning Porter-Cable as a leader in the power tool industry.