Introduction

Preventive Maintenance:

The following system checks should be made every six to twelve months:

Check the Standing Wave Ratio (SWR).

Inspect the tightness of all electrical connections.

Inspect the antenna coaxial cable for wear or breaks on the shielding.

Inspect the tightness of all screws and other mounting hardware.

Troubleshooting:

Should the unit malfunction or perform poorly, follow these procedures:

If the transceiver is completely inoperative: Check the power cord and fuse.

If there is trouble with receiving: Check the VOLUME control setting. Be sure the SQUELCH is adjusted properly. Possibly the radio is over-squelched.

If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely connected to the ANTENNA connector. Check that the antenna is fully extended for proper operation. Check that all transmission line (coaxial cable) connections are secure and free of corrosion.

Blackening may occur on the Liquid Crystal Display if the AM CB Radio has been subjected to extreme high temperature (above 60°C). This is not a fault. Normal LCD operation resumes when the temperature stabilizes back to standard operating condition (0-55°C).

4

Image 4
Contents OWNER’S1 Manual Contents Features IntroductionPreventive Maintenance TroubleshootingControls/Connectors PRO630XL Front ViewConnectors Standard Microphone Controls and Connectors Indicators PRO630XL LCD not to scale IndicatorsIncluded with your AM CB Radio Optional Accessories DIN-E Installation Mounting Using the DIN-E SleeveRemoving the PRO630XL from the DIN-E Sleeve Connecting the Microphone Disconnecting the MIC from the Front MIC JackFront MIC Jack Rear MIC JackConventional Mounting with Screws Mounting the MIC HangerConventional Mounting with Double Sided Tape not supplied MIC Hanger mounted over MIC Cable Standard MicrophoneSetting the Manual Squelch Turning on the PowerOperation Selecting a Channel Programming the Instant Priority Channel Recalling the Instant Priority ChannelTransmitting Call FunctionScanning Open Scan OS Mode Group Scan GS ModePriority Watch Add/Remove Channels from Scan MemoryVOX Operation optional VOX headset required Selecting the Call toneBusy Channel Lockout Roger BeepBeep On/Off Back LightKey Lock ANL Automatic Noise LimiterAM CB Channels & Frequencies 27.055Warranty Uniden PRO630XL AM CB Transceiver RadioUniden Australia Pty Limited/Uniden New Zealand Limited