Oregon Scientific WMR100NA user manual Alternative SET UP Remote Wind Sensor on Existing Pole

Page 6

EN

3.Insert the versatile plastic base into the pole. Align the holes of the pole with the holes of the plastic base.

4.Secure the plastic base by inserting the screw and screwing it tightly into the holes of the plastic base and pole.

IMPORTANT The sensor should be positioned in an open area away from trees or other obstructions.

5.Hammer pole (cone end down) into the ground at the desired spot until versatile plastic base is level with the ground.

TIP Place a block of wood between the pole and the hammer to prevent damage to the pole.

To mount the wind sensor:

13

14

13.Insert the wind vane into the attachment bracket.

14.Screw aluminium pole firmly into place.

IMPORTANT For best results, point the wind vane North.

Securing the assembled remote unit:

6

7

8

9

15.Insert the 2 rectangular base legs through the holes of the versatile base and hammer down.

16.Using the string, tie a knot on the eye pins. Hammer each eye pin into the ground at a 90° angle.

6.Assemble middle pole on top of the bottom one.

7.Using two screws, fix it firmly into place.

8.Assemble top pole on top of the middle one.

9.Using two screws, fix it firmly into place.

11

10

10.Slide the vertical attachment bracket on top of the top pole.

11.Using two screws, fix it firmly into place.

To mount the temperature / humidity sensor:

12

12. Slide outdoor sensor onto vertical attachment

bracket.

6

IMPORTANT Using the fasteners, tighten the string. To tighten, pull fastener down.

To loosen, thread the string up through the fastener eyelets.

ALTERNATIVE SET UP: REMOTE WIND SENSOR ON EXISTING POLE

3

1

2

1.Secure the plastic base onto existing pole with U- bolts, washers and bolts.

2.Insert the horizontal attachment bracket into the base.

3.Using a screw, fix firmly into place.

Image 6
Contents Contents Packaging Contents Base StationWind Sensor / Temperature & Humidity Sensor Rain Gauge Accessories SensorsAssembly Parts Overview Front ViewLCD Display Temperature / Heat Index / Wind Chill AreaBack View Wind Speed / Wind Direction AreaWind Sensor Clock / Alarm / Calendar / Moon Phase AreaReset button Humidity / Dew Point AreaSET UP Remote Temperature / Humidity Sensor Outdoor Temperature / Humidity SensorGetting Started SET UP Remote Wind Sensor Remote Unit AssemblyTo mount the wind sensor Alternative SET UP Remote Wind Sensor on Existing PoleTo mount the temperature / humidity sensor Securing the assembled remote unitSET UP Rain Gauge To set up the Rain GaugeTo ensure a level plane SET UP Base Station Base Station Change Display / SettingClock Reception Clock / Calendar Clock AlarmMoon Phase Auto Scanning FunctionComfort Level Temperature and HumidityTemperature and Humidity Trend Wind Direction / SpeedUVI / Barometer / Rainfall UV IndexBarometer Weather AlarmsSET UP Software First Time USE RainfallTo Disable Sleep Mode on Computer Windows XP Install SoftwareDisable Sleep Mode To Disable Sleep Mode on Computer Windows VistaSpecifications Base Station Software UpdatesReset Indoor TemperatureRF Transmission PrecautionsRelative Humidity Remote Rain GaugeFCC Statement Declaration of ConformityDeclare that the product