Service Code Detection System

The generator may have to run for long periods of time with no operator present. For that reason, the system is equipped with sensors that automatically shut down the generator

in the event of potentially damaging conditions, such as low oil pressure, high temperature, over speed, and other conditions. Refer to Service Code Detection System in the operator’s manual for more detailed information.

Final Installation Considerations

Engine Oil

NOTICE Any attempt to crank or start the engine before it has been properly serviced with the recommended oil will result in equipment failure.

t Refer to Maintenance in the operator’s manual for oil fill information.

t Damage to equipment resulting from failure to follow this instruction will void engine and generator warranty.

The engine is shipped from the factory pre-run and filled with synthetic oil (API SJ/CF 5W-30). This allows for system operation in a wide range of temperature and climate conditions. Before starting the engine, check oil level and ensure that engine is serviced as described in Maintenance of the Operator’s Manual.

The use of synthetic oil does not alter the required oil change intervals described in the Operator’s Manual.

For operation of temperatures below 30°F (-1°C), the use of fully synthetic oil (minimum API SJ) of viscosity 5W30 is required.

Battery

WARNING Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling.

The installer must supply and install a 12 Volt DC rechargeable starting battery. The starting battery MUST conform to the specifications shown below in the chart.

Battery

Standard

Cold Start

Specifications

 

(less than 30°F)

 

 

 

 

 

Volts

12 Volt DC

12 Volt DC

Amps (MIN)

540 CCA (cold

630 CCA (cold

 

cranking amps)

cranking amps)

 

 

 

Construction

Wet lead acid

Wet lead acid

 

 

 

Terminal Type

Top post type

Top post type

 

battery

battery

Dimensions

BCI size 26

BCI size 75

(MAX):

 

 

Install the battery as described in Servicing the Battery in the Maintenance section of the Operator’s Manual. Always make sure the NEGATIVE cable is connected last.

WARNING Storage batteries give off explosive hydrogen gas during recharging.

Slightest spark will ignite hydrogen

and cause explosion, resulting in death, serious injury and/or property damage.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery contents could cause severe chemical burns.

A battery presents a risk of electrical shock and high short circuit current.

t DO NOT dispose of battery in a fire. Recycle battery.

t DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

t DO NOT open or mutilate the battery.

t Wear protective goggles, rubber apron, rubber boots and rubber gloves.

t Remove watches, rings, or other metal objects. t Use tools having insulated handles.

31

Image 31
Contents Generator Systems Date of Purchase Generator For Future ReferenceEngine Table of Contents Safety Symbols and Meanings Important Safety InstructionsFlammable and explosive, which could cause  Tie up long hair and remove jewelry Cold Weather Kit Installing Dealer/Contractor ResponsibilitiesEquipment Description Owner ResponsibilitiesShipment Contents Unpacking PrecautionsDelivery Inspection Unit Information Installation ChecklistInstalling Contractor Information Owner InformationIntentionally Left Blank Exhaust Side of the Generator Generator Placement t &OTVSFFYIBVTUHBTJTLFQUBXBZGSPN Windows C doors Other General Location Guidelines Requirements Placement of Standby Generator to Reduce the Risk of FireAnnex a Explanatory Material AAA Generator InstallationsElectrical and Fuel Inlet Locations Concrete Anchoring of Unit Lifting the GeneratorAccess Ports To remove front panel To remove battery panelTo secure battery panel To open roof t 8IFSFMPDBMDPOEJUJPOTJODMVEFFBSUIRVBLF Gaseous Fuel SystemLP Vapor Propane LP Vapor Natural Content of FuelPower Loss Fuel ConsumptionFuel Conversion System Connectors Generator AC Connection System Utility Circuit Connection Generator Power ConnectionTransfer Switch Communication Grounding the GeneratorGenerator Operation Control Buttons System Control PanelMenu MenuSET Time General Set Up ScreenControl Panel Prompts Automatic ModeGeneral System Parameters Prompts as outlined below Advanced Settings ScreenBattery Standard Cold Start Specifications Service Code Detection SystemFinal Installation Considerations BatteryInitial Start-up No Load Electronic Governing Check Electronic Governor SystemAutomatic Operation Sequence Setting Exercise TimerAntenna Installation # of flashes Service needed Wireless MonitorSystemSYSTEM UPDATEupdate Wireless Monitor OperationOther Installation InspectionWireless Monitor Status LED’s Standard OperationSchematic Diagram Schematic / Wiring DiagramsOn Some UNITS, Wire 1 MAY Also be Labeled AS Wire Wiring Diagram

GEN15ADC-E, GEN16AD-E, GEN20AD-E, Rheem / Ruud standby generator specifications

The Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E models are part of Rheem and Ruud's innovative line of standby generators, designed to provide reliable power solutions for both residential and commercial applications. These generators deliver robust performance, ensuring uninterrupted power supply during outages and emergencies.

The GEN16AD-E and GEN20AD-E generators are particularly noteworthy for their advanced features and technologies. They are equipped with automatic voltage regulation, which helps maintain a steady power supply and protects your appliances from voltage fluctuations. These models also feature a state-of-the-art controller with an LCD display, allowing users to monitor generator performance and status easily. Moreover, they come with a durable, weather-resistant enclosure that is built to withstand various environmental conditions, ensuring longevity and reliability.

Both the GEN16AD-E and GEN20AD-E models incorporate cutting-edge noise reduction technologies, making them some of the quietest generators on the market. This is a significant advantage for residential areas, where noise levels must be kept to a minimum for the comfort of families and neighbors alike. Additionally, their compact design allows for easy installation in limited spaces, making them versatile for various property layouts.

The Rheem / Ruud standby generators are also designed with fuel efficiency in mind. With advanced engine designs and power management features, these units optimize fuel consumption, providing significant cost savings over time. Automatic start systems enhance convenience, enabling the generator to kick in as soon as an outage is detected. This ensures you are never left without power, no matter the circumstances.

The GEN15ADC-E model focuses on delivering a balance of power and efficiency for smaller applications, making it ideal for homeowners looking for lower-capacity solutions without compromising on performance. It also offers features such as digital control panels for easy monitoring and maintenance.

Overall, the Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E standby generators exemplify reliability, efficiency, and user-friendly design. With their impressive features and modern technologies, these generators are a smart investment in power security, ensuring that your home or business stays operational even during unexpected power outages. Their strong reputation in the market reflects the commitment of Rheem and Ruud to provide high-quality products that meet the diverse needs of their customers.