Rheem GEN16AD-E, GEN20AD-E, GEN15ADC-E Installation Checklist, Owner Information, Unit Information

Page 9

Installation Checklist

Proper installation of the home generator requires the completion of the following tasks:

Carbon Monoxide (CO) Detector

Carbon Monoxide (CO) detector installed and in working order.

Smoke detector(s) installed and in working order.

Placement

Required permits have been obtained.

Generator placed in an area free from Carbon Monoxide (CO) buildup. See Placement of Standby Generator to

Reduce the Risk of Carbon Monoxide Poisoning.

Generator placed in an area compliant to NFPA 37. See

Placement of Standby Generator to Reduce the Risk of Fire.

Generator placed in an area free from water damage. See

Other General Location Guidelines.

Generator placed in an area free from utility and other home systems. See Other General Location Guidelines.

Generator placed in a debris free zone. See Other General

Location Guidelines.

Generator placed on flat ground with provisions for water

drainage. See Other General Location Guidelines.

Fuel

Generator is connected to fuel source with flexible fuel line, has no fuel leaks and conforms to local codes. See The

Gaseous Fuel System.

Proper fuel pressure has been measured with all gas appliances operating. See The Gaseous Fuel System.

Fuel system has been configured for the proper fuel supply: Natural gas (NG) or liquefied petroleum ( LP). See Fuel

Conversion.

Fuel type: (circle one) NG LP

'VFMQJQFTJ[FVTFE DJSDMFPOF wwww See NFPA 54, Chapter 6.

Fuel pressure at fuel inlet port with generator on and at full load and all gas appliances turned on and operating

____________________.

Electrical

Generator neutral is connected to Automatic Transfer Switch. See Generator AC Connection System.

Generator is grounded. See Grounding the Generator and

NFPA 70,NEC, Article 250.35B.

Generator is connected to the transfer switch with the specified wiring. See Utility Circuit Connection and

Transfer Switch Communication.

Generator is connected to the transfer switch with the specified wiring. #18AWG twisted pair wiring from the generator control panel to the transfer switch is installed in a separate conduit from high voltage wires unless the insulation rating on all wiring is rated for 600V. See

Transfer Switch Communication.

Dipswitches in most transfer switches must be set to correspond to the wattage of the generator. See Transfer

Switch Operator/Installation Manual.

Operation

Cold weather kit is installed in temperatures below 30°F (4°C). See Cold Weather Kit.

Correct battery type is installed and fully charged. See

Final Installation Considerations.

Generator engine oil level is at full mark. See Final

Installation Considerations.

Circuit breaker is in the ON position.

Utility was shut off to test the operation of generator and transfer switch. Note any fault codes and make corrections as required.

AC Voltage Output___________________________.

Frequency Output___________________________.

Owner Information

Name: ___________________________________________

Address:__________________________________________

Phone/e-mail:______________________________________

Unit Information

Generator Model: ___________________________________

Generator Serial Number: ____________________________

Installing Contractor Information

Name: ___________________________________________

Address:__________________________________________

Phone/FAX: _______________________________________

Electrician: _______________________________________

Signature: ________________________________________

Plumber: _________________________________________

Signature: ________________________________________

Inspector Information

Name: ___________________________________________

Address:__________________________________________

_________________________________________________

Title:_____________________________________________

Inspection Date:____________________________________

This generator has been installed per the manufacturer’s

instructions:

Installing Contractor Signature: ____________________________

Date: _________________________________________________

9

Image 9
Contents Generator Systems For Future Reference Date of Purchase GeneratorEngine Table of Contents Safety Symbols and Meanings Important Safety InstructionsFlammable and explosive, which could cause  Tie up long hair and remove jewelry Equipment Description Installing Dealer/Contractor ResponsibilitiesOwner Responsibilities Cold Weather KitUnpacking Precautions Shipment ContentsDelivery Inspection Installing Contractor Information Installation ChecklistOwner Information Unit InformationIntentionally Left Blank Exhaust Side of the Generator Generator Placement t &OTVSFFYIBVTUHBTJTLFQUBXBZGSPN Windows C doors Other General Location Guidelines Placement of Standby Generator to Reduce the Risk of Fire RequirementsAnnex a Explanatory Material AAA Generator InstallationsElectrical and Fuel Inlet Locations Concrete Anchoring of Unit Lifting the GeneratorAccess Ports To secure battery panel To remove battery panelTo open roof To remove front panel t 8IFSFMPDBMDPOEJUJPOTJODMVEFFBSUIRVBLF Gaseous Fuel SystemPower Loss LP Vapor Natural Content of FuelFuel Consumption LP Vapor PropaneFuel Conversion System Connectors Generator AC Connection System Transfer Switch Communication Generator Power ConnectionGrounding the Generator Utility Circuit ConnectionGenerator Operation Control Buttons System Control PanelMenu MenuSET Time General Set Up ScreenAutomatic Mode Control Panel PromptsGeneral System Parameters Prompts as outlined below Advanced Settings ScreenFinal Installation Considerations Service Code Detection SystemBattery Battery Standard Cold Start SpecificationsInitial Start-up No Load Electronic Governing Check Electronic Governor SystemAutomatic Operation Sequence Setting Exercise TimerAntenna Installation # of flashes Service needed Wireless MonitorSystemSYSTEM UPDATEupdate Wireless Monitor OperationWireless Monitor Status LED’s Installation InspectionStandard Operation OtherSchematic Diagram Schematic / Wiring DiagramsOn Some UNITS, Wire 1 MAY Also be Labeled AS Wire Wiring Diagram

GEN15ADC-E, GEN16AD-E, GEN20AD-E, Rheem / Ruud standby generator specifications

The Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E models are part of Rheem and Ruud's innovative line of standby generators, designed to provide reliable power solutions for both residential and commercial applications. These generators deliver robust performance, ensuring uninterrupted power supply during outages and emergencies.

The GEN16AD-E and GEN20AD-E generators are particularly noteworthy for their advanced features and technologies. They are equipped with automatic voltage regulation, which helps maintain a steady power supply and protects your appliances from voltage fluctuations. These models also feature a state-of-the-art controller with an LCD display, allowing users to monitor generator performance and status easily. Moreover, they come with a durable, weather-resistant enclosure that is built to withstand various environmental conditions, ensuring longevity and reliability.

Both the GEN16AD-E and GEN20AD-E models incorporate cutting-edge noise reduction technologies, making them some of the quietest generators on the market. This is a significant advantage for residential areas, where noise levels must be kept to a minimum for the comfort of families and neighbors alike. Additionally, their compact design allows for easy installation in limited spaces, making them versatile for various property layouts.

The Rheem / Ruud standby generators are also designed with fuel efficiency in mind. With advanced engine designs and power management features, these units optimize fuel consumption, providing significant cost savings over time. Automatic start systems enhance convenience, enabling the generator to kick in as soon as an outage is detected. This ensures you are never left without power, no matter the circumstances.

The GEN15ADC-E model focuses on delivering a balance of power and efficiency for smaller applications, making it ideal for homeowners looking for lower-capacity solutions without compromising on performance. It also offers features such as digital control panels for easy monitoring and maintenance.

Overall, the Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E standby generators exemplify reliability, efficiency, and user-friendly design. With their impressive features and modern technologies, these generators are a smart investment in power security, ensuring that your home or business stays operational even during unexpected power outages. Their strong reputation in the market reflects the commitment of Rheem and Ruud to provide high-quality products that meet the diverse needs of their customers.