Wireless Monitor Operation

1.Remove battery access cover (A) on back of monitor and install 2 AA batteries. (Observe correct battery polarity which is embossed in the bottom of the battery compartment). Replace battery access cover.

5.Locate and hold the SYSTEM UPDATE button (C) on the wireless monitor for 5 seconds. All 3 LEDs will flash until the monitor links to the generator. Once it links, the monitor will display the current state. The monitor will try to link for 1 minute. (This step can only be completed when the generator is in Linking Mode).

GENERATOR POWER

SERVICE NEEDED

systemSYSTEM UPDATEupdate

# of flashes

service needed

1 low battery voltage

5 low frequency

2 low fluid level

6 engine overspeed

3 under/over voltage

7 high temperature

4 engine does not start

8 transfer switch

part #: 316197 fcc id: MCQ-XBS2C IC id: 1846A-XBS2C

+

-

-

+

GENERATOR READY

GENERATOR POWER

A

DEALER NAME

DEALER PHONE

NOTICE The wireless monitor was linked to the generator at the factory. Communication will begin upon the installation of the batteries and the generator being placed in AUTO mode. You may need to press System Update one time

2.The wireless monitor does not have an on/off switch. When batteries are installed correctly, the GENERATOR READY green LED light will flash once every 7 seconds indicating the status of the generator.

NOTICE If communication does not begin upon placing the generator in AUTO, installing batteries, and pressing System Update, the monitor may need to be re-linked. To link, follow Steps 3 through 6.

3.Locate the MENU AND ESCAPE buttons on the control panel (B). Press and hold for 3 seconds to enter the linking mode.

 

SERVICE

NEEDED

C

SYSTEM

UPDATE

6.Once the link has been confirmed, press the OK button on the generator control panel to exit or the control board will turn off linking after 5 minutes. The generator will now communicate with the wireless monitor.

NOTICE It may take up to 1 minute for the monitor to begin displaying the generator status correctly.

B

B

  i-*/,*/(.0%&wXJMMTDSPMMBDSPTTUIFHFOFSBUPS control panel.

37

Image 37
Contents Generator Systems Date of Purchase Generator For Future ReferenceEngine Table of Contents Safety Symbols and Meanings Important Safety InstructionsFlammable and explosive, which could cause  Tie up long hair and remove jewelry Equipment Description Installing Dealer/Contractor ResponsibilitiesOwner Responsibilities Cold Weather KitShipment Contents Unpacking PrecautionsDelivery Inspection Installing Contractor Information Installation ChecklistOwner Information Unit InformationIntentionally Left Blank Exhaust Side of the Generator Generator Placement t &OTVSFFYIBVTUHBTJTLFQUBXBZGSPN Windows C doors Other General Location Guidelines Requirements Placement of Standby Generator to Reduce the Risk of FireAnnex a Explanatory Material AAA Generator InstallationsElectrical and Fuel Inlet Locations Concrete Anchoring of Unit Lifting the GeneratorAccess Ports To secure battery panel To remove battery panelTo open roof To remove front panel t 8IFSFMPDBMDPOEJUJPOTJODMVEFFBSUIRVBLF Gaseous Fuel SystemPower Loss LP Vapor Natural Content of FuelFuel Consumption LP Vapor PropaneFuel Conversion System Connectors Generator AC Connection System Transfer Switch Communication Generator Power ConnectionGrounding the Generator Utility Circuit ConnectionGenerator Operation Control Buttons System Control PanelMenu MenuSET Time General Set Up ScreenControl Panel Prompts Automatic ModeGeneral System Parameters Prompts as outlined below Advanced Settings ScreenFinal Installation Considerations Service Code Detection SystemBattery Battery Standard Cold Start SpecificationsInitial Start-up No Load Electronic Governing Check Electronic Governor SystemAutomatic Operation Sequence Setting Exercise TimerAntenna Installation # of flashes Service needed Wireless MonitorSystemSYSTEM UPDATEupdate Wireless Monitor OperationWireless Monitor Status LED’s Installation InspectionStandard Operation OtherSchematic Diagram Schematic / Wiring DiagramsOn Some UNITS, Wire 1 MAY Also be Labeled AS Wire Wiring Diagram

GEN15ADC-E, GEN16AD-E, GEN20AD-E, Rheem / Ruud standby generator specifications

The Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E models are part of Rheem and Ruud's innovative line of standby generators, designed to provide reliable power solutions for both residential and commercial applications. These generators deliver robust performance, ensuring uninterrupted power supply during outages and emergencies.

The GEN16AD-E and GEN20AD-E generators are particularly noteworthy for their advanced features and technologies. They are equipped with automatic voltage regulation, which helps maintain a steady power supply and protects your appliances from voltage fluctuations. These models also feature a state-of-the-art controller with an LCD display, allowing users to monitor generator performance and status easily. Moreover, they come with a durable, weather-resistant enclosure that is built to withstand various environmental conditions, ensuring longevity and reliability.

Both the GEN16AD-E and GEN20AD-E models incorporate cutting-edge noise reduction technologies, making them some of the quietest generators on the market. This is a significant advantage for residential areas, where noise levels must be kept to a minimum for the comfort of families and neighbors alike. Additionally, their compact design allows for easy installation in limited spaces, making them versatile for various property layouts.

The Rheem / Ruud standby generators are also designed with fuel efficiency in mind. With advanced engine designs and power management features, these units optimize fuel consumption, providing significant cost savings over time. Automatic start systems enhance convenience, enabling the generator to kick in as soon as an outage is detected. This ensures you are never left without power, no matter the circumstances.

The GEN15ADC-E model focuses on delivering a balance of power and efficiency for smaller applications, making it ideal for homeowners looking for lower-capacity solutions without compromising on performance. It also offers features such as digital control panels for easy monitoring and maintenance.

Overall, the Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E standby generators exemplify reliability, efficiency, and user-friendly design. With their impressive features and modern technologies, these generators are a smart investment in power security, ensuring that your home or business stays operational even during unexpected power outages. Their strong reputation in the market reflects the commitment of Rheem and Ruud to provide high-quality products that meet the diverse needs of their customers.