Rheem GEN15ADC-E, GEN20AD-E, GEN16AD-E installation manual  Tie up long hair and remove jewelry

Page 6

WARNING Exhaust heat/gases could ignite combustibles or structures resulting in death, serious

injury and/or property damage. Contact with

muffler area could cause burns resulting in serious injury.

t DO NOT touch hot parts and AVOID hot exhaust gases. t Allow equipment to cool before touching.

t Exhaust outlet side of weatherproof enclosure must have at least 5 ft. (1.5 m) minimum clearance from any structure, shurbs, trees or any kind of vegetation.

t Standby generator weatherproof enclosure must be at least 5 ft. (1.5 m) from windows, doors, any wall opening, shrubs or vegetation over 12 inches (30.5 cm) in height.

t Standby generator weatherproof enclosure must have a minimum of 5 ft. (1.5 m) overhead clearance from any structure, overhang or trees.

t DO NOT place weatherproof enclosure under a deck or other type of structure that may confine airflow.

t Use only flexible fuel line provided. Connect provided fuel line to generator, DO NOT use with or substitute any other flexible fuel line.

t Smoke detector(s) MUST be installed and maintained indoors according to the manufacturer’s instructions/ recommendations. Carbon monoxide alarms cannot detect smoke.

t Keep at least minimum distances shown in General Location Guidelines to insure for proper generator cooling and maintenance clearances.

t It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest- covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.

Contact the original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.

t Replacement parts must be the same and installed in the same position as the original parts.

WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories resulting in serious injury.

t NEVER operate generator without protective housings, covers, or guards in place.

t DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts.

t Tie up long hair and remove jewelry.

t Before servicing, remove 15 Amp fuse from control panel and disconnect Negative (NEG or -) battery cable.

CAUTION Installing the 15A fuse could cause the engine to start at any time without warning resulting in minor or moderate injury.

t Observe that the 15 Amp fuse has been removed from the control panel for shipping.

t DO NOT install this fuse until all plumbing and wiring has been completed and inspected.

CAUTION Excessively high operating speeds could result in minor injury and/or equipment damage, Excessively low speeds impose a heavy load on generator. t DO NOT tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed speed.

t DO NOT modify generator in any way.

NOTICE Improper treatment of generator could damage it and shorten its life.

t Use generator only for intended uses.

t If you have questions about intended use, contact your authorized dealer.

t Operate generator only on level surfaces.

t Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation.

t The access panels/doors must be installed whenever the unit is running.

t DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

t Remain alert at all times while working on this equipment. Never work on the equipment when you are physically or mentally fatigued.

t DO NOT start engine with air cleaner or air cleaner cover removed.

t DO NOT insert any objects through cooling slots.

t DO NOT use the generator or any of its parts as a step. Stepping on the unit could cause stress and break parts. This may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

t If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator and contact an authorized deaker if

-electrical output is lost;

-equipment sparks, smokes, or emits flames;

-unit vibrates excessively;

-unit makes unusual noises.

6

Image 6
Contents Generator Systems For Future Reference Date of Purchase GeneratorEngine Table of Contents Important Safety Instructions Safety Symbols and MeaningsFlammable and explosive, which could cause  Tie up long hair and remove jewelry Owner Responsibilities Installing Dealer/Contractor ResponsibilitiesEquipment Description Cold Weather KitUnpacking Precautions Shipment ContentsDelivery Inspection Owner Information Installation ChecklistInstalling Contractor Information Unit InformationIntentionally Left Blank Generator Placement Exhaust Side of the Generator t &OTVSFFYIBVTUHBTJTLFQUBXBZGSPN Windows C doors Other General Location Guidelines Placement of Standby Generator to Reduce the Risk of Fire RequirementsAnnex a Explanatory Material Generator Installations AAAElectrical and Fuel Inlet Locations Lifting the Generator Concrete Anchoring of UnitAccess Ports To open roof To remove battery panelTo secure battery panel To remove front panelGaseous Fuel System  t 8IFSFMPDBMDPOEJUJPOTJODMVEFFBSUIRVBLFFuel Consumption LP Vapor Natural Content of FuelPower Loss LP Vapor PropaneFuel Conversion System Connectors Generator AC Connection System Grounding the Generator Generator Power ConnectionTransfer Switch Communication Utility Circuit ConnectionSystem Control Panel Generator Operation Control ButtonsMenu MenuGeneral Set Up Screen SET TimeAutomatic Mode Control Panel PromptsGeneral System Parameters Advanced Settings Screen Prompts as outlined belowBattery Service Code Detection SystemFinal Installation Considerations Battery Standard Cold Start SpecificationsInitial Start-up No Load Electronic Governor System Electronic Governing CheckSetting Exercise Timer Automatic Operation SequenceAntenna Installation Wireless Monitor # of flashes Service neededWireless Monitor Operation SystemSYSTEM UPDATEupdateStandard Operation Installation InspectionWireless Monitor Status LED’s OtherSchematic / Wiring Diagrams Schematic DiagramWiring Diagram On Some UNITS, Wire 1 MAY Also be Labeled AS Wire

GEN15ADC-E, GEN16AD-E, GEN20AD-E, Rheem / Ruud standby generator specifications

The Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E models are part of Rheem and Ruud's innovative line of standby generators, designed to provide reliable power solutions for both residential and commercial applications. These generators deliver robust performance, ensuring uninterrupted power supply during outages and emergencies.

The GEN16AD-E and GEN20AD-E generators are particularly noteworthy for their advanced features and technologies. They are equipped with automatic voltage regulation, which helps maintain a steady power supply and protects your appliances from voltage fluctuations. These models also feature a state-of-the-art controller with an LCD display, allowing users to monitor generator performance and status easily. Moreover, they come with a durable, weather-resistant enclosure that is built to withstand various environmental conditions, ensuring longevity and reliability.

Both the GEN16AD-E and GEN20AD-E models incorporate cutting-edge noise reduction technologies, making them some of the quietest generators on the market. This is a significant advantage for residential areas, where noise levels must be kept to a minimum for the comfort of families and neighbors alike. Additionally, their compact design allows for easy installation in limited spaces, making them versatile for various property layouts.

The Rheem / Ruud standby generators are also designed with fuel efficiency in mind. With advanced engine designs and power management features, these units optimize fuel consumption, providing significant cost savings over time. Automatic start systems enhance convenience, enabling the generator to kick in as soon as an outage is detected. This ensures you are never left without power, no matter the circumstances.

The GEN15ADC-E model focuses on delivering a balance of power and efficiency for smaller applications, making it ideal for homeowners looking for lower-capacity solutions without compromising on performance. It also offers features such as digital control panels for easy monitoring and maintenance.

Overall, the Rheem GEN16AD-E, GEN20AD-E, and GEN15ADC-E standby generators exemplify reliability, efficiency, and user-friendly design. With their impressive features and modern technologies, these generators are a smart investment in power security, ensuring that your home or business stays operational even during unexpected power outages. Their strong reputation in the market reflects the commitment of Rheem and Ruud to provide high-quality products that meet the diverse needs of their customers.