Telex ELECTRO-VOICE X-Line TM manual Table of Contents

Page 2

Table of Contents

 

Rigging-Safety Warning

2

0 Introduction

3

1 X-Line Rigging System

4

1.1

Overview of the X-Line Flying System

4

1.2

Enclosure Rigging Hardware Details

6

1.3

Rear Rigging Hinge Details

10

1.4

Front Rigging Strap Details

13

1.5

Xvbp Pull-Up Bar Details

16

1.6

ATM X-Line Grid Details

17

1.7

RS-1B Double-Stud Rigging Fitting

18

2 X-Line Rigging and Flying Techniques

19

2.1

Array Considerations

19

2.2

Adjusting the Vertical Angles of the Enclosures

19

2.3

Deciding Whether to Use an Xvhg or Xvhl at the Grid

21

2.4

Rigging an Array with Boxes Using X-Line Dollies

22

2.5

Pull-Up Techniques

25

3 Rigging-Strength Ratings, Safety Factors, and Special Safety Considerations

26

3.1

Working-Load Limit (WLL) and Safety Factors

26

3.2

Structural Rating Overview

26

3.3

Simplified Structural-Rating Guidelines

27

3.4

Complex Structural-Rating Analysis

30

3.5

Wind Loading

38

3.6

Electro-Voice Structural-Analysis Procedures

38

4 Rigging Inspection and Precautions

39

References

...............................................................................................................................................................

41

Notes

42

1

ELECTRO-VOICE®￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Image 2
Contents Line Rigging Manual Table of Contents Rigging-Safety Warning Introduction Line Rigging System Overview of the X-Line Flying SystemTypical X-Line Flying System Enclosure Rigging Hardware Details Xvls Loudspeaker System Xfil1 and Xfil2 Loudspeaker Systems Xfil1 & Xfil2 Front Rigging with Xvsd or Xvhp Straps Rear Rigging Hinge Details Rear Rigging Hardware Installation Details External Rigging Hardware DetailsELECTRO-VOICE Front Rigging Strap Details Front Rigging Hardware Installation Details ELECTRO-VOICE Xvbp Pull-Up Bar Details ATM Flyware X-Line Grid ATM X-Line Grid DetailsRS-1B Double-Stud Rigging Fitting Array Considerations Adjusting the Vertical Angles of the EnclosuresLine Rigging and Flying Techniques Enclosure Vertical Angle Adjustments Rectangular Box Xvls or Xsub to Trapezoidal Box XvltDeciding Whether to Use an Xvhg or Xvhl at the Grid Rigging an Array with Boxes Using X-Line Dollies Flying with Stacking Dollies Flying with Front Dollies Pull-Up Techniques Working-Load Limit and Safety Factor Definitions Structural Rating OverviewSimplified Structural-Rating Guidelines Simplified Rating Guidelines ELECTRO-VOICE Complex Structural-Rating Analysis MAX +∅ -∅ Working-Load Limit 750 lb 340 kg At Any Angle ELECTRO-VOICE Xvls, Xvlt & Xsub Overall Enclosure Structural Ratings Xfil1 & Xfil2 Overall Enclosure Structural RatingsXvbp Structural Ratings Xvbp Pull-Up Bar Structural-Strength RatingsRS-1B Structural-Strength Ratings Xvls, Xvlt & Xsub Front Rigging Point Structural Ratings Xfil1 & Xfil2 Front Rigging Point Structural RatingsElectro-Voice Structural-Analysis Procedures Wind LoadingRigging Inspection and Precautions Electro-Voice X-Line Loudspeaker SystemsELECTRO-VOICE Mechanical Engineering References ReferencesRigging References ELECTRO-VOICE Telex Communications, Inc /2002 Part Number 38110-158 Rev a