The Xfil1 and Xfil2 enclosures use a slightly different rigging track arrangement at the front. In this case, another pair of proprietary
To facilitate the installation and removal of the linking hinges, alignment feet are installed on the top and bottom of the
1.3 Rear Rigging Hinge Details
Figure 4 shows the X-Line external rigging hardware details and key dimensions.
Xvhg Grid Hinge: Two Xvhg grid hinges can be used to attach the back of an X-Line enclosure to the back of an X-Line-compatible grid. Each grid hinge consists of two precision-machined steel bases connected by an alloy-steel chain, as shown in Figure 4. Each grid-hinge base has a locking pin that locks the hinge in place horizontally in the track on the grid or X-Line enclosure.
The Xvhg grid rigging hinges need not be installed in the top enclosure and the grid simultaneously. The length of chain allows the grid hinges to be installed in the grid first. The grid can then be floated above the top enclosure while the other ends of the grid hinges are installed in the track at the rear of the enclosures. The grid hinges must be installed with the hinge bases located at the outside of the track towards the sides of the enclosure as shown in Figure 5 with the locking pins on the fittings located next to the sides of the enclosure.
To install an Xvhg grid hinge into the track of an enclosure, grasp one of the hinge bases and firmly insert it into the long cutout in the track, pressing in until the spring-loaded locking pin is fully retracted. Then apply pressure to slide the hinge base sideways towards the end of the track until the spring-loaded locking pin drops into the hinge-locking-pin hole in the base of the track. Once the locking pin is fully engaged, the grid hinge base will be immovable in the track. Use the same technique for installing the other end of the Xvhg grid hinge in the track at the rear of the grid. The user must be careful not to insert a twist in the chain when installing the second end. A twist will result in the grid hinge assembly being shorter and will introduce excessive forces in the chain.
ALWAYS CHECK TO MAKE SURE THAT THE GRID HINGE BASES ARE INSTALLED IN THE CORRECT ORIENTATION WITH THE HINGES AT THE OUTSIDE EDGES OF THE TRACK. ALWAYS CHECK TO MAKE SURE THE
10 |