The bar graph displays the columns sequentially from “0” to “7” until all columns are showing. Then they are hidden again, and the sequential display is repeated. It is possible to read each column, one at a time—simultaneously displaying the numeric measurement for that column directly under the bar graph. To do this:

1.Press the RAIN button twice, either “DAY,” “WEEK,” or “MONTH” should flash to the left of the “RAIN” icon.

2.Press the SET button, column “0” will flash, and the rainfall measurement value is displayed directly under the bar graph.

3.Press the CH/+ button to toggle through columns “0” to “7.”

4.While column “7” is flashing press the CH/+ button to exit this mode.

V.RAINFALL QUANTITY

The rainfall quantities can be displayed 4 different ways, represented by 4 different time period icons, and measured in 2 different units of measure (inches or millimeters). The quantities are displayed in the lower portion of LCD 5, and the time period icons appear between the quantity and the bar graph.

1.While in normal viewing mode, press the “RAIN” key once. The current selected period will flash (“TOTAL”, “1H, “24H”, or the rain icon).

2.Press the “+” key to toggle through the selections. Following is a list of the 4 time period icons and a description of what they represent.

“TOTAL”—(the default setting) shows the total accumulated rainfall since the last set-up or manual reset.

“1h”—shows the rainfall measurement of the past hour. Information is updated every hour on the half-hour (i.e. …at 6:30, at 7:30 and at 8:30…).

“24h”—shows the measured rainfall of the last 24-hour period. Updates are made daily at 7:00 am.

rain icon”—resets automatically at the beginning of a rainfall, it will show and keep track of the current rainfall quantities, once the current rainfall is complete it will display the quantity of that rainfall until a new rain begins, then it will automatically reset.

3.Press the “RAIN” key twice to exit this mode, or do not press any buttons for 20 seconds.

17

Image 17
Contents Page Table of Contents Quick SET-UP Guide Inventory of ContentsRainfall Sensor Detailed SET-UP Guide Battery InstallationRemote THERMO-HYGRO Sensor LCD Screens Weather CenterII. Setting the LCD Contrast Program ModeFunction Buttons III /24 Hour Time Display SelectionVI. Date Setting IV. Time SettingTime Zone Setting VIII. Selecting F or C and Inches or Millimeters VII. Date Display SettingIX. Weather Forecast Sensitivity Setting Displaying Relative hPa/inHg or Absolute hPa/inHg XII. Selecting BAR Graph Display XI. Manually Setting the Relative AIR PressureWaning Moon Phases Features & Operations Moon PhaseII. Minimum & Maximum Temperatures Displays and Functions Weather Icons Resetting the Minimum & Maximum RecordsIII. Weather Forecast & Weather Icons Storm Warning Comfort Level IndicatorWeather Tendency Arrows IV. BAR Graph Histories AIR Pressure History Rainfall History Rainfall Quantity Manual Setting of the Rain Multiplicator VI. Resetting Rainfall Information Rainfall Quantity TotalsVII. Adding More Sensors optional Hard Reset of Eeprom Weather Center MemoryMounting SET-UP of Multiple SensorsSelecting Which Sensor Data to Display Mounting with Adhesive Tape TX4U-REMOTE THERMO-HYGRO SensorMounting with the Screws III. the WS-7095U-WEATHER Center II. the TX5U-RAINFALL SensorHanging holes Troubleshooting Maintenance and CareProblem SolutionSpecifications Dimensions L x W x H Sensor reading updatePower supply Warranty Information Support@lacrossetechnology.com