VI. RESETTING RAINFALL INFORMATION

A.RAINFALL QUANTITY TOTALS

Resetting the Rainfall Quantity Totals will clear the numeric data held under “TOTAL,” “1h,” and “24h,” resetting all to 0.00 (appearing in LCD 5).

From any selected normal display mode:

1.Press and hold the RAIN button for 3 seconds.

2.Resetting will automatically shift to display “TOTAL.” The numeric data under “TOTAL” in LCD 5 will read 0.00.

Note: Resetting the Rainfall Quantity Totals does not affect the Rainfall History represented in the bar graph.

B.MANUAL SETTING OF THE RAIN MULTIPLICATOR

Note: The rain multiplicator is the height of rain held in the teeter-totter bucket (inside the rain gauge) before it is tipped. It is preset to a value of 0.267mm by the manufacturer prior to shipping; this number produces the most accurate rainfall measurement. There is no need to manually set this number unless it has been changed.

1.Remove the batteries and wait 30 seconds. (This will also reset the Rainfall Quantity Totals).

2.Checking the polarity, install batteries.

3.During the brief 2 seconds that all LCD screens light up, simultaneously press and hold the MOON and MIN/MAX buttons.

4.Three numbers will appear in LCD1 (“267” is the default), with the last digit (7) flashing.

5.Use the CH/+ button to change the last digit to a 7 and press the SET button.

6.Use the CH/+ button to change the middle digit to a 6 and press the SET button.

7.Use the CH/+ button to change the first digit to a 2 and press the SET button. The Weather Center will enter into normal operating mode. Do not press any buttons while the Weather Center searches for transmisssion signals.

8.Follow Program Mode for set-up proceedures.

18

Image 18
Contents Page Table of Contents Inventory of Contents Quick SET-UP GuideDetailed SET-UP Guide Battery Installation Remote THERMO-HYGRO SensorRainfall Sensor Weather Center LCD ScreensFunction Buttons Program ModeII. Setting the LCD Contrast III /24 Hour Time Display SelectionIV. Time Setting Time Zone SettingVI. Date Setting VII. Date Display Setting IX. Weather Forecast Sensitivity SettingVIII. Selecting F or C and Inches or Millimeters Displaying Relative hPa/inHg or Absolute hPa/inHg XI. Manually Setting the Relative AIR Pressure XII. Selecting BAR Graph DisplayFeatures & Operations Moon Phase Waning Moon PhasesII. Minimum & Maximum Temperatures Displays and Functions Resetting the Minimum & Maximum Records III. Weather Forecast & Weather IconsWeather Icons Comfort Level Indicator Weather Tendency ArrowsStorm Warning IV. BAR Graph Histories AIR Pressure History Rainfall History Rainfall Quantity VI. Resetting Rainfall Information Rainfall Quantity Totals Manual Setting of the Rain MultiplicatorHard Reset of Eeprom Weather Center Memory VII. Adding More Sensors optionalSET-UP of Multiple Sensors Selecting Which Sensor Data to DisplayMounting TX4U-REMOTE THERMO-HYGRO Sensor Mounting with the ScrewsMounting with Adhesive Tape II. the TX5U-RAINFALL Sensor III. the WS-7095U-WEATHER CenterHanging holes Problem Maintenance and CareTroubleshooting SolutionSpecifications Sensor reading update Power supplyDimensions L x W x H Warranty Information Support@lacrossetechnology.com