La Crosse Technology WS-2510 manual Outdoor sensors fields 3 to, Wind measurement field

Page 16

3.2.1.2. Outdoor sensors (fields 3 to 6)

3 4 5

2

1

7

2

3 4

6 2

1

47

6

3 7

6

The top right hand field of the display is associated with the outdoor wireless sensors for temperature/humidity. It displays the following information from left to right:

1.Tendency arrow symbols: Indication of the tendency of the temperature at the location of the selected outdoor

sensor compared with the last value received: rising (arrow pointing upwards) or falling (arrow pointing downwards).

2.Alternative display of the current temperature (see example left), perceived temperature (“Wind chill”, see example right) or dew point (“Dew point”, see example bottom center) for the currently selected sensor.

3.Here, the “Graph” symbol shows that the trend display for the currently displayed outdoor temperature has been selected in the history field. It only appears if it has previously been selected (see 3.2.6.:“History ”). The trend can also be displayed for the humidity.

4.Temperature display units. ºC or ºF depending on selection in configuration mode.

5.Comfort indicator: Display of the ambient climatic conditions at the selected sensor by means of three face symbols. You will find the appropriate data for interpreting these symbols in the section “Explanation of terms”. The comfort indicator is only displayed when the temperature is displayed.

6.Relative humidity at the location of the currently selected sensor in percent.

7.Indication of the current outdoor sensor selected. If there is only one outdoor sensor available, this display field is not used.

Please note:

If a sensor does not support humidity monitoring, the text “Humidity”, the percent sign and the comfort indicator will not be displayed.

Key functions (Allocation of touch screen fields, see page 9)

-Touch screen field 3 switches over between the display of temperature, perceived temperature and dew point.

-Touch screen field 4 selects the next sensor if available (1 …8)

-Touch screen field 5 selects the previous sensor if available (8 …1)

3.2.2.Wind measurement (field 7)

The display field for the wind measurement is situated in the middle on the left.

Here the main wind direction, the range of variation of wind direction and the wind speed are displayed.

2

1

2

3

4

3

2

1

2

1 3

1.The main wind direction is shown by the double-headed arrow on the wind compass rose.

2.If there is a variation in wind direction this is shown by means of several single-headed arrows to the left and right of the main wind direction (max.3 in each direction).

3.Depending on the selection, the wind speed in km/h, m/s, mph, knots or Beaufort or the numerical value of the wind direction in degrees of a full circle is shown in the center of the wind compass rose.

16

Image 16
Contents Touch Screen Wireless Weather Station WS-2510 25-26 Contents27-28 Display of the indoor temperature in F or C and humidity General information and functioningDisplay of wind speed with wind direction and variation Display of the amount of rainfall in mm, l/m2 or inchesOther Quick overview of the display fields on the main displayBattery operation Operation using the power adaptorPC connection optional Bus connectionSetting up/Wall mounting CommissioningPlease note Previous weather sensors with software Version Outdoor sensorsDescription, Installation and Commissioning of sensors Insertion of magnets into the outdoor sensors1 WS-2510-15 wind sensor 2 WS-2510-16 rain sensor5 WS-2510-22 temperature/humidity sensor 6 WS-2510-27 temperature/humidity sensor7 WS-2510-25 temperature/humidity outdoor sensor Brightness sensor WS-2510-19Basic settings, Configuration OperationGeneral settings Illumination settings Cleaning modeConfiguration Wwvb and sensor receptionSetting the temperature display units Illumination time for battery operationIllumination time for AC adaptor operation Setting the rainfall display units Calibration of the rainfall reading indicatorAir pressure display correction Setting the air pressure display units Setting the display type for the history trend display Setting the time function Keypad beep on/offSetting the day and the date Sensor administrationPlease note Protocol versionNormal display function Key functions Allocation of touch screen fields, seeOutdoor sensors fields 3 to Wind measurement fieldRainfall measurement fields 8/9 Air pressure measurement fields 10/11Weather forecast Following particular features should be noted Hours of sunshineBrightness No key functionsTime/Date Key functionsMinimum/Maximum value display Example for the display of maximum valuesDeleting min/max values History display for min/max valuesAlarm values can be set for Programming mode entering alarm valuesProgramming the min/max alarm values Setting/Resetting the MIN/MAX alarm values Setting the wake-up times Please noteAlarm initiation, Alarm reset Display exampleChanging batteries Base station Information on fault removalSensor batteries are discharged Range Maintenance and servicing informationRepeater for range increase Perceived temperature -see Wind chill Technical dataExplanation of terms Wind strength table Beaufort Wind speed Description Warranty Information