La Crosse Technology WS-2510 Hours of sunshine, Following particular features should be noted

Page 19

Please note:

-With temperature and pressure, the history is shown referred to the current value.

Here the display can optionally be in the form of a bar or line diagram according to the setting in the configuration mode.

-With humidity, wind speed, rainfall, hours of sunshine (8-day trend only) and brightness, the history is shown as the absolute value with the bottom line as the zero reference. In this case the display is always in the form of a bar diagram.

Key functions (Allocation of touch screen fields, see page 9)

-Touch screen field 16 activates the selection mode (“SELECT”)

-Touch screen fields 17 and 18 switch over the display mode (8 days/24 h).

3.2.7.Hours of sunshine

The display field for the hours of sunshine (SUNSHINE DURATION) is situated at the bottom left of the display. Here the hours of sunshine are displayed in three ways:

Total:

1

2

3

Last day

2

1

Current day

3

1

1.The hours of sunshine are either displayed as a total (“h”; since the last deletion), the last hour (“h/day”) or the current day (“current h/day”).

The following particular features should be noted:

The hours of sunshine for the “last day” are always calculated at 0:00 hours.

2. Here, the “Graph” symbol shows that the trend display for the hours of sunshine has been selected in the

history field. It only appears if it has previously been selected (see 3.2.6.:“History”). Only the 8-day trend is available.

3.Sun symbol: indicates the current sunshine, i.e. the symbol appears as long as the brightness sensor registers a brightness level above the threshold set in the configuration mode.

Please note:

-From 0 to 99:59 h the time is displayed in the form hh:mm (resolution 1 min)

-From 100.0 to 999.9 h the time is displayed in the form hhh.h (resolution 1/10 h)

-From 1000 to 9999 h the time is displayed in the form hhhh (resolution 1 h)

Key functions (Allocation of touch screen fields, see page 9)

-Touch screen field 19 switches over the display mode. Switching sequence: Total, last day, current day.

-If touch screen field 26 (“RESET”) is pressed briefly, the point in time at which the total value was last deleted will be displayed in the date and time field.

-If touch screen field 26 (“RESET”) is pressed for 3 seconds, the total value will be deleted.

3.2.8.Brightness

The display field for the current brightness (BRIGHTNESS) is situated at the bottom right of the display:

1

2

1.The current brightness is displayed in lux or klux as appropriate.

2.Here, the “Graph” symbol shows that the trend display for the brightness has been selected in the history field. It only appears if it has previously been selected.

No key functions.

19

Image 19
Contents Touch Screen Wireless Weather Station WS-2510 25-26 Contents27-28 Display of the amount of rainfall in mm, l/m2 or inches Display of the indoor temperature in F or C and humidityGeneral information and functioning Display of wind speed with wind direction and variationQuick overview of the display fields on the main display OtherBus connection Battery operationOperation using the power adaptor PC connection optionalOutdoor sensors Setting up/Wall mountingCommissioning Please note Previous weather sensors with software Version2 WS-2510-16 rain sensor Description, Installation and Commissioning of sensorsInsertion of magnets into the outdoor sensors 1 WS-2510-15 wind sensorBrightness sensor WS-2510-19 5 WS-2510-22 temperature/humidity sensor6 WS-2510-27 temperature/humidity sensor 7 WS-2510-25 temperature/humidity outdoor sensorOperation Basic settings, ConfigurationWwvb and sensor reception General settings Illumination settingsCleaning mode ConfigurationSetting the temperature display units Illumination time for battery operationIllumination time for AC adaptor operation Setting the rainfall display units Calibration of the rainfall reading indicatorAir pressure display correction Keypad beep on/off Setting the air pressure display unitsSetting the display type for the history trend display Setting the time functionProtocol version Setting the day and the dateSensor administration Please noteKey functions Allocation of touch screen fields, see Normal display function Wind measurement field Outdoor sensors fields 3 toAir pressure measurement fields 10/11 Rainfall measurement fields 8/9Weather forecast No key functions Following particular features should be notedHours of sunshine BrightnessExample for the display of maximum values Time/DateKey functions Minimum/Maximum value displayHistory display for min/max values Deleting min/max valuesAlarm values can be set for Programming mode entering alarm valuesProgramming the min/max alarm values Setting the wake-up times Please note Setting/Resetting the MIN/MAX alarm valuesDisplay example Alarm initiation, Alarm resetChanging batteries Base station Information on fault removalSensor batteries are discharged Range Maintenance and servicing informationRepeater for range increase Perceived temperature -see Wind chill Technical dataExplanation of terms Wind strength table Beaufort Wind speed Description Warranty Information