Karcher HD 4000 C, HD 6000 C Stopping the System, Frost Protection, System Shut-Down

Page 10

English

B. System Operation

HD 4000 C / HD 6000 C

!Danger!

nHealth hazard through cleaning detergents.

Due to the possible adding of detergents to the system water, the water exiting from the system must not be used as drinking water.

Switching the System ON

Open the water tap for water supply and cooling water.

Turn the Emergency-STOP master switch (Q1) to the I (ON) position.

Press the unlock button (S1).

nCarry out the cleaning procedure. The pump stops for a cleaning break of more than 15 seconds. At the same time the 6 hours of continuous availability time is started.

Within the availability time the system starts automatically owing to the drop in pressure when opening a handgun.

Restoring Operational Readiness

Press the unlock button (S1).

4. Stopping the System

Turn the system’s Emergency- STOP master switch to the 0 (OFF) position.

Shut OFF the water supply.

Open the handgun until the water pressure has dissipated.

Using the locking feature, secure the handgun against being opened accidentally.

5. Frost Protection

The water-bearing parts of the system must be protected from freezing, since they could otherwise be destroyed. If the system is to be operated also in freezing temperatures, it must be installed in a frost- free location. Outdoor water lines must be frost-protected (i.e., through insulation or line heaters, or by draining during freezing temperatures).

6. System Shut-Down

If a system is to be shut down during cold periods, it must first be flushed with an antifreeze solution. As a rule, antifreeze products also contain corrosion inhibitors.

B3

5.956-648 A10369 (06/98)

Image 10
Contents HD 4000 C Packaging materials Operating InstructionsProper disposal for the sake of our environment Operating mediaTable of Contents System Operating Hazards For Your SafetySafety Instructions and Information EnglishEnglish Hazards posed by defective equipment Hazards posed by AccessoriesHazards during work on the system Authorised Operators Safety Measures on the Installation SiteNoise Protection Personal Protective EquipmentGuidelines and Regulations Protective DevicesEmergency Drill Proper Use of the EquipmentSystem Operation Operating ControlsUsing Emergency-STOP Starting the SystemFrost Protection Switching the System onStopping the System System Shut-DownFlow Diagram System FunctionDescription of Functions Specifications Equipment FeaturesHD 6000 C 967-045 With hot-water Connected Loads Specifications Dimension Diagram Maintenance Contract MaintenanceMaintenance Schedule Maintenance Interval Procedure Subject Assembly Activity By whom Maintenance Maintenance Decalcification Removing the CoverProceed as follows Trouble Shooting Problem Possible Cause Remedy By whomEnglish Problem Possible cause Remedy By whom Trouble Shooting Trouble Shooting High-pressure Installation System InstallationPlacement ConnectionsHard-water Treatment Preparations for CommissioningSpace Assignment Plan Accessories Accessories Customer Service