Karcher HD 4000 C, HD 6000 C Trouble Shooting, Problem Possible Cause Remedy By whom

Page 24

English

F. Trouble Shooting

HD 4000 C / HD 6000 C

Problem

 

Possible Cause

Remedy

by whom

 

 

 

 

High-pressure

Leaking suction-side tubing

Check fastener and hose

Operator

pump fails to

 

system

connections

 

come up to

 

Water starvation

Correct the cause

Operator

pressure

 

 

 

 

 

 

 

 

Defective valve in pump

Replace valves

Customer

 

 

 

High-pressure solenoid valve

 

Service

 

 

 

fails to close

 

 

 

 

 

 

Pronounced pump

Defective dashpot

replace

Operator

knock, pressure

Pump is drawing air

Check suction line

Operator

gauge pointer

 

 

 

oscillates

 

Defective valve seat or valve

Replace as required

Customer

 

 

 

spring

 

Service

With hot-water

Defective or calcified

Check precompression

Operator

accessory kit only

precompression pump

pump

 

 

 

 

 

Overflow volume

Blown hose between overflow

replace

Operator

is blown out into

valve and float valve

 

 

open, and/or

 

 

 

 

safety valve is

Defective overflow valve

Repair or exchange

Customer

activated

 

 

CAUTION: For safety reasons,

overflow valve

Service

 

 

 

 

 

 

excess water is vented

 

 

 

 

 

outdoors.

 

 

 

 

 

Shut down the system!!

 

 

 

 

 

 

Water is returning

System is calcified

Decalcify system circuits

Operator

to float reservoir

 

(refer to Maintenance

 

despite full-volume

 

section)

 

usage

 

Defective spray lances and/or

Check spray lances

Operator

 

 

 

 

 

 

nozzles.

 

 

 

 

 

Defective overflow valve

Check overflow valve

Cust. Service

 

 

 

 

Overflow valve

Leak in high-pressure system,

Repair leak

Operator

cycles ON and

defective spray gun.

 

 

OFF despite zero

Leaking non-return valve or

Repair overflow valve

Customer

usage

 

 

control piston seal in overflow

 

Service

 

 

 

 

 

 

 

valve

 

 

 

 

 

 

Pump does not

Blocked strainer upstream of

Clean strainer

Operator

reach working

solenoid valve

 

 

RPM with

and/

Defective pressure relief

Replace solenoid valve

Customer

or

- starter.

solenoid valve

 

Service

 

 

 

 

 

 

 

 

 

 

F1

5.956-648 A10369 (06/98)

Image 24
Contents HD 4000 C Operating Instructions Proper disposal for the sake of our environmentPackaging materials Operating mediaTable of Contents For Your Safety Safety Instructions and InformationSystem Operating Hazards EnglishHazards posed by Accessories English Hazards posed by defective equipmentHazards during work on the system Safety Measures on the Installation Site Noise ProtectionAuthorised Operators Personal Protective EquipmentProtective Devices Emergency DrillGuidelines and Regulations Proper Use of the EquipmentSystem Operation Operating ControlsUsing Emergency-STOP Starting the SystemSwitching the System on Stopping the SystemFrost Protection System Shut-DownFlow Diagram System FunctionDescription of Functions Specifications Equipment FeaturesHD 6000 C 967-045 With hot-water Connected Loads Specifications Dimension Diagram Maintenance Maintenance ContractMaintenance Schedule Maintenance Interval Procedure Subject Assembly Activity By whom Maintenance Maintenance Removing the Cover DecalcificationProceed as follows Trouble Shooting Problem Possible Cause Remedy By whomEnglish Problem Possible cause Remedy By whom Trouble Shooting Trouble Shooting System Installation PlacementHigh-pressure Installation ConnectionsHard-water Treatment Preparations for CommissioningSpace Assignment Plan Accessories Accessories Customer Service