English
F. Trouble Shooting
HD 4000 C / HD 6000 C
Problem |
| Possible Cause | Remedy | by whom | ||
|
|
|
| |||
Leaking | Check fastener and hose | Operator | ||||
pump fails to |
| system | connections |
| ||
come up to |
| Water starvation | Correct the cause | Operator | ||
pressure |
| |||||
|
|
|
| |||
|
|
| Defective valve in pump | Replace valves | Customer | |
|
|
|
| Service | ||
|
|
| fails to close |
|
| |
|
|
|
| |||
Pronounced pump | Defective dashpot | replace | Operator | |||
knock, pressure | Pump is drawing air | Check suction line | Operator | |||
gauge pointer | ||||||
|
|
| ||||
oscillates |
| Defective valve seat or valve | Replace as required | Customer | ||
|
|
| spring |
| Service | |
With | Defective or calcified | Check precompression | Operator | |||
accessory kit only | precompression pump | pump |
| |||
|
|
|
| |||
Overflow volume | Blown hose between overflow | replace | Operator | |||
is blown out into | valve and float valve |
|
| |||
open, and/or |
|
|
|
| ||
safety valve is | Defective overflow valve | Repair or exchange | Customer | |||
activated |
| |||||
| CAUTION: For safety reasons, | overflow valve | Service | |||
|
|
| ||||
|
|
| excess water is vented |
|
| |
|
|
| outdoors. |
|
| |
|
|
| Shut down the system!! |
|
| |
|
|
|
| |||
Water is returning | System is calcified | Decalcify system circuits | Operator | |||
to float reservoir |
| (refer to Maintenance |
| |||
despite |
| section) |
| |||
usage |
| Defective spray lances and/or | Check spray lances | Operator | ||
|
|
| ||||
|
|
| nozzles. |
|
| |
|
|
| Defective overflow valve | Check overflow valve | Cust. Service | |
|
|
|
| |||
Overflow valve | Leak in | Repair leak | Operator | |||
cycles ON and | defective spray gun. |
|
| |||
OFF despite zero | Leaking | Repair overflow valve | Customer | |||
usage |
| |||||
| control piston seal in overflow |
| Service | |||
|
|
|
| |||
|
|
| valve |
|
| |
|
|
|
| |||
Pump does not | Blocked strainer upstream of | Clean strainer | Operator | |||
reach working | solenoid valve |
|
| |||
RPM with | and/ | Defective pressure relief | Replace solenoid valve | Customer | ||
or | - starter. | |||||
solenoid valve |
| Service | ||||
|
|
|
| |||
|
|
|
|
|
|
F1 |