English
F. Trouble Shooting
HD 4000 C / HD 6000 C
| Problem | 
 | Possible Cause | Remedy | by whom | ||
| 
 | 
 | 
 | 
 | |||
| Leaking  | Check fastener and hose | Operator | ||||
| pump fails to | 
 | system | connections | 
 | ||
| come up to | 
 | Water starvation | Correct the cause | Operator | ||
| pressure | 
 | |||||
| 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | Defective valve in pump | Replace valves | Customer | |
| 
 | 
 | 
 | 
 | Service | ||
| 
 | 
 | 
 | fails to close | 
 | 
 | |
| 
 | 
 | 
 | 
 | |||
| Pronounced pump | Defective dashpot | replace | Operator | |||
| knock, pressure | Pump is drawing air | Check suction line | Operator | |||
| gauge pointer | ||||||
| 
 | 
 | 
 | ||||
| oscillates | 
 | Defective valve seat or valve | Replace as required | Customer | ||
| 
 | 
 | 
 | spring | 
 | Service | |
| With  | Defective or calcified | Check precompression | Operator | |||
| accessory kit only | precompression pump | pump | 
 | |||
| 
 | 
 | 
 | 
 | |||
| Overflow volume | Blown hose between overflow | replace | Operator | |||
| is blown out into | valve and float valve | 
 | 
 | |||
| open, and/or | 
 | 
 | 
 | 
 | ||
| safety valve is | Defective overflow valve | Repair or exchange | Customer | |||
| activated | 
 | |||||
| 
 | CAUTION: For safety reasons, | overflow valve | Service | |||
| 
 | 
 | 
 | ||||
| 
 | 
 | 
 | excess water is vented | 
 | 
 | |
| 
 | 
 | 
 | outdoors. | 
 | 
 | |
| 
 | 
 | 
 | Shut down the system!! | 
 | 
 | |
| 
 | 
 | 
 | 
 | |||
| Water is returning | System is calcified | Decalcify system circuits | Operator | |||
| to float reservoir | 
 | (refer to Maintenance | 
 | |||
| despite  | 
 | section) | 
 | |||
| usage | 
 | Defective spray lances and/or | Check spray lances | Operator | ||
| 
 | 
 | 
 | ||||
| 
 | 
 | 
 | nozzles. | 
 | 
 | |
| 
 | 
 | 
 | Defective overflow valve | Check overflow valve | Cust. Service | |
| 
 | 
 | 
 | 
 | |||
| Overflow valve | Leak in  | Repair leak | Operator | |||
| cycles ON and | defective spray gun. | 
 | 
 | |||
| OFF despite zero | Leaking  | Repair overflow valve | Customer | |||
| usage | 
 | |||||
| 
 | control piston seal in overflow | 
 | Service | |||
| 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | valve | 
 | 
 | |
| 
 | 
 | 
 | 
 | |||
| Pump does not | Blocked strainer upstream of | Clean strainer | Operator | |||
| reach working | solenoid valve | 
 | 
 | |||
| RPM with | and/ | Defective pressure relief | Replace solenoid valve | Customer | ||
| or | - starter. | |||||
| solenoid valve | 
 | Service | ||||
| 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | |
| F1 |