HD 4000 C / HD 6000 C
F. Trouble Shooting
English
Problem | Possible cause | Remedy | by whom | |
|
|
|
| |
| Insufficient water in | Check site water supply | Operator | |
| float tank |
|
| |
General fault and |
|
|
| |
“Water supply fault” |
|
|
| |
LED light up on |
|
|
| |
printed circuit board | Temperature of the water | Reduce inlet temperature | Operator | |
| inlet too high |
|
| |
|
|
|
| |
| Cooling water quantity too |
|
| |
| low: |
|
| |
General fault and | Strainer in pressure reduction | Clean strainer | Operator | |
“HD pump | ||||
valve contaminated |
|
| ||
temperature fault” |
|
| ||
|
|
| ||
LED light up on | Mains water pressure too low | Raise pressure | Operator | |
printed circuit board | Cooling coil calcified, | Decalcify, | Operator | |
| ||||
| solenoid valve defective | replace solenoid valve |
| |
|
|
|
| |
| Oil level too low | Check oil level | Customer | |
|
|
| Service | |
|
|
|
| |
| Oil change not made, owing | Check pump parts, | Customer | |
| to which there is oil carbon | replace as necessary. | Service | |
| under the piston guide shoes, | Make an oil change |
| |
| piston seizing. |
|
| |
|
|
|
| |
| Rotation direction of | Change rotation direction | Electrician | |
| precompression pump wrong |
|
| |
General fault and |
|
|
| |
“Admission pressure |
|
|
| |
of |
|
|
| |
too low” LED light |
|
|
| |
up. (Only with ABS | Pressure switch | Replace pressure switch | Customer | |
hot water) | precompression |
| Service | |
| pump in the ABS hot water |
|
| |
| defective |
|
| |
|
|
|
| |
| Too many utilisers | Close down some utilisers | Operator | |
| simultaneously opened |
|
| |
General fault and |
|
|
| |
“Drop in system |
|
|
| |
pressure” LED light |
|
|
| |
up on the printed | Pipe burst in the | Turn off installation and | Customer | |
circuit board (flow | ||||
repair pipeline | Service | |||
without pressure | ||||
|
|
| ||
longer than | Pressure switch defective | Replace pressure switch | Customer | |
15 seconds) |
|
| Service | |
|
|
|
|
F2 |