ASSEMBLY
CONNECTING THE HIGH PRESSURE HOSE TO |
| |
THE PUMP | COLLAR | |
See Figure 9. | ||
| ||
������After the high pressure hose has been uncoiled and attached |
| |
to the spray wand: |
| |
Align the collar on the threaded nipple on the pump. |
| |
Insert the nozzle on the end of the high pressure hose |
| |
collar into the threaded nipple. |
|
Turn the collar clockwise to tighten the hose securely to the pump.
Pull on the hose to be certain it is properly secured.
CONNECTING THE GARDEN HOSE TO THE | THREADED | |
PRESSURE WASHER | NIPPLE | |
See Figure 10. | Fig. 9 | |
The water supply must come from a water main. NEVER | WATER | |
use hot water or water from pools, lakes, etc. Before | ||
INTAKE | ||
connecting the garden hose to the pressure washer: |
| |
Run water through the hose for 30 seconds to clean any |
| |
debris from the hose. |
| |
Inspect the screen in the water intake. |
| |
If the screen is damaged, do not use the machine until | GARDEN | |
the screen has been replaced. | ||
HOSE |
If the screen is dirty, clean it before connecting the garden hose to the machine.
������To connect the garden hose to the machine:
Uncoil the garden hose.
NOTE: There must be a minimum of 10 feet of |
|
|
unrestricted hose between the pressure washer intake and | SCREEN |
|
the hose faucet or shut off valve (such as a “Y” shut off | Fig. 10 | |
connector). |
| |
|
|
With the hose faucet turned completely off, attach the end of the garden hose to the water intake. Tighten by hand.
OPERATION
WARNING:
Do not allow familiarity with tools to make you care- less. Remember that a careless fraction of a second is sufficient to inflict serious injury.
WARNING:
Always wear safety goggles or safety glasses with side shields when operating tools. Failure to do so could result in objects being thrown into your eyes, resulting in possible serious injury.
WARNING:
Do not use any attachments or accessories not recom- mended by the manufacturer of this tool. The use of attachments or accessories not recommended can result in serious personal injury.
WARNING:
Do not direct discharge stream at persons. Failure to heed this warning could result in serious injury.