Section
7
Troubleshooting
TROUBLESHOOTING
Problem | Cause | Correction | |||
|
|
|
|
| |
| 1. | Low pressure nozzle installed. | 1. | Replace nozzle with high pressure | |
|
|
|
| nozzle. | |
| 2. | Water inlet is blocked. | 2. | Clear inlet. | |
| 3. | Inadequate water supply. | 3. | Provide adequate water flow. | |
| 4. | Inlet hose is kinked or leaking. | 4. | Straighten inlet hose, patch leak. | |
Pump has following problems: | 5. | Clogged inlet hose strainer. | 5. | Check and clean inlet hose | |
failure to produce pressure, erratic |
|
|
| strainer. | |
pressure, chattering, loss of | 6. | Water supply is over 100°F. | 6. | Provide cooler water supply. | |
pressure, low water volume. | 7. | High pressure hose is blocked or | 7. | Clear blocks in outlet hose. | |
| |||||
|
| leaks. |
|
| |
| 8. | Gun leaks. | 8. | Replace gun. | |
| 9. | Nozzle is obstructed. | 9. | Clean nozzle. | |
| 10. | Pump is faulty. | 10. | Contact Briggs & Stratton Power | |
|
|
|
| Products service facility. | |
|
|
|
|
| |
| 1. | Chemical | 1. | Rotate chemical | |
|
| "Off" position. |
| desired chemical reservoir to "On" | |
Detergent fails to mix with spray. |
|
|
| position. | |
2. | Dirty | 2. | See "Check | ||
| |||||
| 3. | High pressure nozzle installed. | 3. | Replace nozzle with low pressure | |
|
|
|
| nozzle. | |
|
|
| |||
| Engine speed is too slow. | Move throttle control to FAST | |||
Engine runs good at |
|
| position. If engine still "bogs down", | ||
"bogs" when load is added. |
|
| contact Briggs and Stratton service | ||
|
|
| facility. | ||
|
|
| |||
Engine shuts down during | Out of gasoline. | Fill fuel tank. | |||
operation. |
|
|
|
| |
|
|
|
|
|