THE UNIT MUST BE TRANSPORTED

 

 

 

 

 

IN THE UP-RIGHT POSITION AT ALL

 

 

 

 

 

TIMES AND MUST NOT BE DROPPED

 

 

 

 

OR TAILGATED. DAMAGE TO THE

 

 

 

5' Minimum

 

UNIT DURING TRANSPORTATION IS

 

 

 

 

NOT THE RESPONSIBILITY OF THE

 

 

 

 

 

MANUFACTURER.

 

 

 

 

.

 

 

 

 

 

Unit Location

 

 

 

18"

Min

 

 

 

 

Once the unit has been inspected and

 

 

18"

 

 

 

 

 

cleared of any transportation damage,

 

 

18"

 

 

Min.

 

 

 

18“ min

 

 

it is now time to locate the pool heater.

 

 

18“Minmin.

It is very important to understand the

 

 

 

 

 

location of the unit for the best

 

 

 

 

 

performance of operation. See Figure 1

 

 

 

 

for location recommendations. A

 

 

 

 

 

minimum of 18" of clearance between

 

 

 

 

the evaporator coils and shrubs, fences,

Figure 1 -

.

 

 

 

 

 

 

adequate air intake. A minimum of 5' of

36"Min

 

 

Unit Location

 

 

walls, etc. must be maintained for

 

 

 

 

 

vertical clearance between the top of

 

NOTE: This type of constant

to prevent damage to the

the unit and any roof overhang or other

obstructions must be maintained in

 

watering directly on the unit can

condenser shell and coil due to the

order to prevent the re-circulation of

 

void your warranty.

expansion of freezing water.

cold air back into the evaporator coils.

 

Condensation drain holes are provided

The minimum water circulation

This is to maintain the efficiency of the

in all units for adequate removal of

capacity flowing through the pool

unit. A minimum of 36" of clearance

 

condensation and rainwater. ALL

heater is 25 gallons per minute and

between the front of the unit (access

 

UNITS WILL HAVE CONDENSATION.

the maximum capacity is 80 gallons

panel area) and any obstruction must

 

THIS SHOULD NOT BE MISTAKEN

per minute.

 

be maintained to allow maintenance on

FOR A LEAK IN THE UNIT.

Do not install a water shutoff valve in

the unit when necessary. The unit

 

Plumbing

 

 

 

the piping from the outlet of the pool

should be located on a solid level

 

 

 

heater to the pool or tub. However, a

surface, a minimum of 36"x 36" for

 

 

 

 

 

 

check valve that does not include a

proper drainage. Make sure any

 

Where freezing weather is encountered,

 

shut-off feature may be installed for

sprinkler heads are not directly spraying

the detachable connection/union

convenience during servicing.

water on the unit. While heat pumps

 

(provided) must be installed

 

A check valve or Hartford Loop is

are made for an outdoor environment,

immediately adjacent to the heater to

recommended between the unit and a

they are not designed to have sprinkler

facilitate servicing and draining of the

chlorinator. The chlorinator must be

water constantly spraying them.

 

heat exchanger. Draining is necessary

 

downstream of the heat pump. Failure

 

 

 

 

 

 

 

 

to do so may void the warranty.

POOL

 

 

 

If you have an in-floor cleaning

 

 

 

system, please take note of any special

HEATER

 

 

 

plumbing requirements to operate all

UNIONS

 

 

units effectively.

 

 

Figure 2 shows the recommended

 

 

 

 

IN

 

FILTER

 

installation layout.

 

 

Basic Heat Pump

OUT

 

 

 

 

 

 

Operation

CHECK

 

 

 

CHLORONATOR

 

 

 

VALVE

 

Electrical Connections

 

 

 

 

 

WARM

 

 

All

 

 

POOL

 

wiring

 

 

WATER OUT

PUMP

and electrical connections must be

 

 

TO POOL

 

performed by a qualified electrician.

 

 

COLD WATER

 

Installations must be in accordance with

Figure 2 -

 

 

local and national codes.

Recommended installation layout

 

IN FROM POOL

 

 

 

 

 

 

 

 

www.aquaprosystems.com

 

Phone: (877)-278-2797

 

 

 

 

 

 

2

Image 4
Contents Heat Pump Pool Heater Bomba DE Calor Para Piscinas Page Important Safety Instructions ContentsInstallation Procedures Basic Heat Pump OperationUnit Location PlumbingElectronic Temp. Controls Indicator Lights Manual Temperature ControlsPRO1100 PRO1100e PRO1300PRO1300h/c PRO1300, PRO1100e, PRO1300h/c, PRO1100PRO1100e TCE PRO1300 TCEPRO1100e TCE & PRO1300 TCE wiring diagram Activating and Setting System Run Time TCO OperationToggling Between Heating and Cooling Mode PRO1300h/c TCEElectronic Temp Controls Selecting Functionality of UnitMaintenance Activating and Setting system run timeUnit leaves the factory with the FIL mode set to OFF Time Clock Override TCO OperationTroubleshooting Guide Application GuidelinesTroubleshooting Limited Warranty Índice Guías de seguridadProcedimientos de instalación Inspección de la unidadUbicación de la unidad PlomeríaFuncionamiento básico de la bomba de calor Procedimientos deControles electrónicos de temperatura Todas las Controles de temp. manuales Controles electrónicos de temperaturaLuces indicadoras Figura 5 diagrama de cableado PRO1100e TCE PRO1300 TCE Selección de la funcionalidad de la unidadOperación con Eliminación del Temporizador TCE Ciclo de descongelaciónOperación con Limitación del Temporizador TCO Para TCO opcionalFigura 9 Diagrama de cableado La unidad viene de fábrica con el modo FIL apagado OFFVea la Figura 9 para el cableado de la función TCE Pautas de aplicación CondensaciónCubiertas para piscinas MantenimientoGuía de diagnóstico y resolución de problemas Aberturas de la piscinaCondiciones climáticas DiagnósticosGuía de diagnóstico y resolución de Garantía Limitada 13 SpNotas

PRO1100e, PRO1300 TCE, PRO1300, PRO1100, PRO1100e TCE specifications

The AquaPRO PRO1300h/c TCE, PRO1300 TCE, PRO1100e TCE, PRO1100, and PRO1100e are a series of high-performance water treatment systems designed to meet the diverse needs of residential and commercial users. These models stand out due to their advanced technology, energy efficiency, and user-friendly operation, making them ideal for various water purification tasks.

The AquaPRO PRO1300h/c TCE is equipped with advanced filtration technology that combines multiple filtration stages, ensuring the removal of contaminants, odors, and unpleasant tastes from the water. Its high-capacity system is perfect for larger households or small businesses, treating up to 1,300 gallons per day. This model features a compact design, which simplifies installation and saves valuable space, while providing a robust solution for clean drinking water.

The PRO1300 TCE model mirrors many features of the PRO1300h/c but is tailored for specific applications where heating or cooling functions are not necessary. It retains the high filtration capacity and incorporates smart technology that allows users to monitor water quality in real-time. The user-friendly interface and app connectivity offer convenient access to system status and maintenance alerts.

Moving down the range, the AquaPRO PRO1100e TCE offers slightly lower filtration capabilities but maintains the same commitment to quality and efficiency. Perfect for medium-sized households, the PRO1100e TCE boasts an eco-friendly design that minimizes energy consumption without compromising on performance. It features a smart leak detection system that alerts users in the event of any leaks, safeguarding both the unit and the property.

The PRO1100 is a more basic model intended for users seeking simplicity without sacrificing performance. It offers reliable filtration with easy-to-replace cartridges and minimal maintenance requirements, making it an excellent choice for those new to water filtration systems.

Lastly, the PRO1100e is designed for environments where energy efficiency is prioritized. Its reduced operational costs make it particularly attractive to eco-conscious consumers. With durable construction and a simple interface, these models ensure longevity and ease of use, appealing to a wide demographic.

In conclusion, the AquaPRO range encompasses various models, each with distinct features that cater to different filtration needs while ensuring high-quality performance, making the AquaPRO systems a wise investment for clean, safe water.