Zenoah G3000 manual OP9 Adjusting Carburetor OP9, Needle 11⁄4±1⁄4

Page 12

7. Operation

OP9

ADJUSTING CARBURETOR (OP9)

The carburetor has been adjusted at the factory. Should your unit need readjustment due to the changes in altitude or operating conditions, please let your skillful dealer make the adjustment. A wrong adjustment may cause damage to your unit. If you have to make the adjustment yourself, please carefully follow the procedure below.

NOTE

Be sure to adjust the carburetor with the bar chain attached.

1.Stop engine and screw in both H and L needles until they stop. Never farce. Then set them back the standard number of turns as shown below.

H needle: 114±14

L needle: 114±14

2.Start engine and allow it a few minutes warming up in low speed.

3.Turn L needle slowly clockwise to find the position where idling speed is maximum, set the needle back a quarter (1/4) turn counterclockwise. L needle should be set in 1/4 turn either wise from the standard position.

4.Turn idle adjusting screw (T) counterclockwise so that saw chain does not turn. If idling speed is too slow, turn the screw clockwise.

5.Make a test cut and adjust the H needle for best cutting power, not for maximum speed.

12

Image 12
Contents G3000 2631-93111205Page Safety First ContentsSpecifications Parts locationG3000 Symbols on the machine For safe operation Kickback Safety Precautions for Chain SAW Users Installing guide bar and saw chain SE1 SE2 SE3 SE4 SE525 1 Mix Chart Fuel and chain oilFuel Recommended mixing ratioOperation OP1 OP2 OP3 OP4 OP5 Fueling the Unit OP1Starting Engine OP6 OP7 OP8 Checking OIL SupplyStopping Engine OP9 Adjusting Carburetor OP9 Needle 11⁄4±1⁄4Sawing SA1 SA2To Avoid Kickback SA1 Felling a Tree SA2SA3 SA4 SA5 Logging and Limbing Cutting an unpillowed logCutting a pillowed log SA6 Maintenance Daily Maintenance SAW ChainMA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8 Guide BAR AIR FilterMonthly Maintenance Fuel Filter MA9Oiling Port GeneralStorage Handle Mounting Joints