Minimum Power Notes:

All minimum power specifications are based on 0.1% regulated AC mains and an ambient room temperature of 70°F (21°C). International units with multi-tap transformers are specified for the worst-case transformer tap (normally 100 VAC, 50 Hz). The standard EIA power measurement (RS-490) is not identified here because it is identical to the FTC Continuous Average Power specification.

1.A 1-kHz sine wave is presented to the ampli- fier and the output monitored for nonlinear dis- tortion. The level is increased until the THD reaches 0.1%. At this level the average power per channel is reported.

2.A sine wave is presented to the amplifier over the range from 20 Hz to 20 kHz and the output monitored for nonlinear distortion. The level at each frequency is increased until the THD reaches 0.1%. At this level the average power per channel is reported.

3.A 1-kHz sine wave is presented to the ampli- fier and the output monitored for nonlinear dis- tortion. The level is increased until the THD reaches 0.05%. At this level the average power per channel is reported.

4.Continuous power in the context of Federal Trade Commission testing is understood to be a minimum of five minutes of operation. Harmonic distortion is measured as the RMS sum total and given as a percentage of the fundamental output voltage. This applies for all wattages greater than 0.25 watts.

page 28

Operation Manual

Image 28
Contents Macro-Tech Some models may be exported under the name AmcronImportant Safety Instructions Watch for These SymbolsSafety Standard Crown International, IncTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents Features How to Use This ManualWelcome Setup Unpack Your Amplifier Install Your AmplifierYou may also stack amps without using a cabinet 48.3 cmChoose Input Wire Connectors Choose Output Wire and Con- nectorsWire Your System Stereo ModeSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Startup Procedure PrecautionsOperation Set Input SensitivityFront Panel Controls and Indicators Signal/IOC IndicatorsOdep Indicators Enable IndicatorBack Panel Controls, Indicators and Connec Tors Power Cord Stereo/Mono SwitchInput Sensitivity Switch not shown Input Ground Lift SwitchIndicators IndicatorsAdvanced Features Options Standby ModeProtection Systems OdepHere are some of their many features Advanced FeaturesFuses and Circuit Breakers Options PIP and PIP2 Modules PIP2 Adapter ConnectionCooling Fan Options Level Control Shaft LockTroubleshooting Please refer to the block diagram in Figure Theory of OperationOverview Circuit TheoryBridge-Mono Operation Parallel-Mono Operation120 VAC, 60 Hz Units, Bridge mono mode Specifications120 VAC, 60 Hz Units, Parallel mono mode Power Draw at Idle Dimensions WidthWeight Net Weight Shipping WeightMaximum Power Notes Macro-Tech 602 Maximum Power MatrixMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Minimum Power Notes Macro-Tech 602 Minimum Power MatrixMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix AC Power Draw andThermal Dissipation Constant 0.35 is inefficiency 1.00-0.65AC Power Draw Thermal Dissipation Service Warranty United States & CanadaReason for failure, except as excluded in this Warranty 12/01MA Series Power Amplifiers Crown Audio Factory Service Information