5 Advanced Features and Options

For PIP2s featuring ribbon cable connectors, simply locate the two connectors on the under- side of the PIP circuit board, then connect the two input ribbon cables coming from the ampli- fier (see Figure 5.3). Both ribbon cables should run smoothly from the amplifier to the PIP card. Insert the PIP and attached cables into the PIP opening in the back of the amplifier, then screw securely into place.

WARNING: Disconnect power to the amplifier when installing or removing a PIP module.

5.3.2 Cooling Fan Options

Every Macro-Tech amplifier has a built-in high- velocity fan that provides optimum cooling. Two optional replacement fan blades are available for special cooling requirements. Crown part C 6594-3 is a quieter, low-velocity fan blade that in many cases can provide adequate cooling. Crown part C 6593-5 is a reverse air-flow fan blade which changes the direction of the air flow in and out of the amplifier (not recommended for the Macro-Tech 2402). Important: The optional replacement fan blades should only be installed by a qualified tech- nician.

5.3.3 Level Control Shaft Lock

A security accessory, the shaft lock can be used to secure your amplifier's level controls in situations where the front panel controls are subject to tamper- ing. One is needed for each channel. They can be ordered through the Crown Service/Parts Depart- ment. For more information, contact your local Crown dealer or Crown Technical Support.

Figure 5.3 Installing a PIP2 Module

Figure 5.4 Installing a Level Control Shaft Lock

Operation Manual

page 17

Image 17
Contents Some models may be exported under the name Amcron Macro-TechWatch for These Symbols Important Safety InstructionsCrown International, Inc Safety StandardTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents Welcome How to Use This ManualFeatures Unpack Your Amplifier Install Your Amplifier SetupYou may also stack amps without using a cabinet 48.3 cmChoose Output Wire and Con- nectors Choose Input Wire ConnectorsStereo Mode Wire Your SystemSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Precautions Startup ProcedureOperation Set Input SensitivitySignal/IOC Indicators Front Panel Controls and IndicatorsOdep Indicators Enable IndicatorStereo/Mono Switch Back Panel Controls, Indicators and Connec Tors Power CordInput Sensitivity Switch not shown Input Ground Lift SwitchIndicators IndicatorsStandby Mode Advanced Features OptionsProtection Systems OdepFuses and Circuit Breakers Advanced FeaturesHere are some of their many features PIP2 Adapter Connection Options PIP and PIP2 ModulesLevel Control Shaft Lock Cooling Fan OptionsTroubleshooting Theory of Operation Please refer to the block diagram in FigureOverview Circuit TheoryParallel-Mono Operation Bridge-Mono Operation120 VAC, 60 Hz Units, Parallel mono mode Specifications120 VAC, 60 Hz Units, Bridge mono mode Dimensions Width Power Draw at IdleWeight Net Weight Shipping WeightMacro-Tech 602 Maximum Power Matrix Maximum Power NotesMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Macro-Tech 602 Minimum Power Matrix Minimum Power NotesMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix Constant 0.35 is inefficiency 1.00-0.65 AC Power Draw andThermal DissipationAC Power Draw Thermal Dissipation Service United States & Canada Warranty12/01 Reason for failure, except as excluded in this WarrantyMA Series Power Amplifiers Crown Audio Factory Service Information