Crown Audio MA-1202, MA-602 Front Panel Controls and Indicators, Dust Filters, Level Controls

Page 11

MA Series Power Amplifiers

4 Operation

4.2Front Panel Controls and Indicators

The diagram below shows the controls and indicators on the front panel of the Macro-Tech 02 Series.

A. Dust Filters

The dust filters remove large particles from the air drawn in by the cooling fan. Check the filters regularly to prevent clogging. The filter ele- ments can be easily removed for cleaning by gently pulling them away from the front panel.

B. Level Controls

The output level for each channel is set with these convenient Level controls mounted on the front panel. Each level control has 31 detents for precise adjustment. A security option is available to prevent tampering (see Section 5.3.3).

C. Signal/IOC® Indicators

These green multifunction indicators show sig- nal presence and distortion for each channel. As signal presence indicators, they flash syn- chronously with the output audio signals to show their presence. As IOC (Input/Output Comparator) indicators, they flash brightly with a 0.1 second hold delay if there is a difference of 0.05% or more between the input and output signal waveforms. This provides proof of dis- tortion-free performance. Note: The Channel 2 IOC indicator stays on in Parallel-Mono mode (see Section 3.6.3).

D. ODEP Indicators

During normal operation of the ODEP (Output Device Emulation Protection) circuitry, these amber indicators glow brightly to show the presence of reserve thermal-dynamic energy.

They dim proportionally as energy reserves decrease. In the rare event that energy reserves are depleted, the indicators turn off and ODEP proportionally limits output drive so the ampli- fier can safely continue operating even under severe conditions. These indicators can also help identify more unusual operating condi- tions (see Section 5.1.1).

E. Enable Indicator

This indicator lights when the amplifier has been "enabled" or turned on, and AC power is available.

F. Enable Switch

This push button is used to turn the amplifier on and off. When turned on, the output is muted for approximately four seconds to pro- tect your system from start-up transients. (This delay can be changed. Contact Crown's Techni- cal Support Group for details.)

Figure 4.1 Front Panel Controls & Indicators

Operation Manual

page 11

Image 11
Contents Some models may be exported under the name Amcron Macro-TechWatch for These Symbols Important Safety InstructionsCompetent Body’s Name and Address Safety StandardCrown International, Inc TCF Technical Certificate No P4300CRI1.IWSTable of Contents Welcome How to Use This ManualFeatures 48.3 cm SetupUnpack Your Amplifier Install Your Amplifier You may also stack amps without using a cabinetChoose Output Wire and Con- nectors Choose Input Wire ConnectorsBridge-Mono Mode Wire Your SystemStereo Mode See .6. Set the back panel stereo/mono switch to StereoParallel-Mono Mode Set Input Sensitivity Startup ProcedurePrecautions OperationEnable Indicator Front Panel Controls and IndicatorsSignal/IOC Indicators Odep IndicatorsInput Ground Lift Switch Back Panel Controls, Indicators and Connec Tors Power CordStereo/Mono Switch Input Sensitivity Switch not shownIndicators IndicatorsOdep Advanced Features OptionsStandby Mode Protection SystemsFuses and Circuit Breakers Advanced FeaturesHere are some of their many features PIP2 Adapter Connection Options PIP and PIP2 ModulesLevel Control Shaft Lock Cooling Fan OptionsTroubleshooting Circuit Theory Please refer to the block diagram in FigureTheory of Operation OverviewParallel-Mono Operation Bridge-Mono Operation120 VAC, 60 Hz Units, Parallel mono mode Specifications120 VAC, 60 Hz Units, Bridge mono mode Shipping Weight Power Draw at IdleDimensions Width Weight Net WeightMacro-Tech 602 Maximum Power Matrix Maximum Power NotesMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Macro-Tech 602 Minimum Power Matrix Minimum Power NotesMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix Constant 0.35 is inefficiency 1.00-0.65 AC Power Draw andThermal DissipationAC Power Draw Thermal Dissipation Service United States & Canada Warranty12/01 Reason for failure, except as excluded in this WarrantyMA Series Power Amplifiers Crown Audio Factory Service Information