8 Specifications

Maximum Power Notes:

All maximum power specifications are based on 0.1% regulated AC mains and an ambient room temperature of 70°F (21°C). International units with multi-tap transformers are specified for the best-case transformer tap (normally 240 VAC, 60 Hz). Although it is an unusual condition, your amplifier can function well with AC mains volt- ages up to 10% over the specified line voltage. With overvoltage conditions, your amplifier may be capable of delivering instantaneous power levels up to 20% greater than the specifications in the matrix.

1. A single cycle sine wave is presented to the amplifier and monitored for nonlinear distortion. The average power during the burst is reported. Loudspeakers must be able to withstand this level if they are to be safely used with this ampli- fier.

2. A 40-millisecond sine wave burst (10% duty cycle) is presented to the amplifier and moni- tored for nonlinear distortion. The average power during the burst is reported. This power level is a measurement of the amplifier’s maximum tran- sient power than can be perceived by the human ear.

Figure 8.2 Macro-Tech 1202 Maximum Power Matrix

page 24

Operation Manual

Image 24
Contents Macro-Tech Some models may be exported under the name AmcronImportant Safety Instructions Watch for These SymbolsSafety Standard Crown International, IncTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents How to Use This Manual FeaturesWelcome Setup Unpack Your Amplifier Install Your AmplifierYou may also stack amps without using a cabinet 48.3 cmChoose Input Wire Connectors Choose Output Wire and Con- nectorsWire Your System Stereo ModeSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Startup Procedure PrecautionsOperation Set Input SensitivityFront Panel Controls and Indicators Signal/IOC IndicatorsOdep Indicators Enable IndicatorBack Panel Controls, Indicators and Connec Tors Power Cord Stereo/Mono SwitchInput Sensitivity Switch not shown Input Ground Lift SwitchIndicators IndicatorsAdvanced Features Options Standby ModeProtection Systems OdepAdvanced Features Here are some of their many featuresFuses and Circuit Breakers Options PIP and PIP2 Modules PIP2 Adapter ConnectionCooling Fan Options Level Control Shaft LockTroubleshooting Please refer to the block diagram in Figure Theory of OperationOverview Circuit TheoryBridge-Mono Operation Parallel-Mono OperationSpecifications 120 VAC, 60 Hz Units, Bridge mono mode120 VAC, 60 Hz Units, Parallel mono mode Power Draw at Idle Dimensions WidthWeight Net Weight Shipping WeightMaximum Power Notes Macro-Tech 602 Maximum Power MatrixMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Minimum Power Notes Macro-Tech 602 Minimum Power MatrixMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix AC Power Draw andThermal Dissipation Constant 0.35 is inefficiency 1.00-0.65AC Power Draw Thermal Dissipation Service Warranty United States & CanadaReason for failure, except as excluded in this Warranty 12/01MA Series Power Amplifiers Crown Audio Factory Service Information