Crown Audio MA-1202, MA-602 operation manual Welcome, How to Use This Manual, Features

Page 5

MA Series Power Amplifiers

MA-602

*1 kHz

**20 Hz–20 kHz

Power

Power

2 ohm Dual (per ch.)

400W

335W

4 ohm Dual (per ch.)

325W

300W

8 ohm Dual (per ch.)

225W

210W

4 ohm Bridge-Mono

750W

650W

8 ohm Bridge-Mono

655W

605W

*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD.

**20 Hz–20 kHz Power: refers to maximum average power in watts from 20 Hz to 20 kHz with 0.1% THD.

MA-1202

*1 kHz

**20 Hz–20 kHz

Power

Power

2 ohm Dual (per ch.)

675W

585W

4 ohm Dual (per ch.)

480W

450W

8 ohm Dual (per ch.)

310W

295W

4 ohm Bridge-Mono

1,300W

1,130W

8 ohm Bridge-Mono

970W

895W

*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD.

**20 Hz–20 kHz Power: refers to maximum average power in watts from 20 Hz to 20 kHz with 0.1% THD.

MA-2402

*1 kHz **20 Hz–20 kHz

Power

Power

2 ohm Dual (per ch.)

1,050W

850W

4 ohm Dual (per ch.)

800W

750W

8 ohm Dual (per ch.)

520W

505W

4 ohm Bridge-Mono

2,070W

1,670W

8 ohm Bridge-Mono

1,585W

1,485W

*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD.

**20 Hz–20 kHz Power: refers to maximum average power in watts from 20 Hz to 20 kHz with 0.1% THD.

1 Welcome

Congratulations on purchasing one of the renowned Crown® Macro-Tech®power ampli- fiers. They are designed to provide enormous levels of pure, undistorted power in a rugged, low-profile package — making them the choice for pro sound reinforcement. They utilize our patented ODEP® protection circuitry to keep the show going long after other amplifiers have shut down. And with their PIPexpandability, Macro-Tech amplifiers can be easily custom- ized with one of our many optional input mod- ules (see Section 5 for a list of available PIPs).

Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power levels. They must be treated with respect and correctly installed if they are to provide the many years of reliable service for which they were designed.

In addition, the Macro-Tech 02 Series amplifi- ers include a number of features which require some explanation before they can be used to their maximum advantage.

Please take the time to study this manual so that you can obtain the best possible service from your amplifier.

1.1 Features

Crown’s Grounded-Bridge design deliv- ers large voltage swings without using easily stressed output-transistor configu- rations like conventional amplifiers. The results are lower distortion and superior reliability.

Patented ODEP (Output Device Emulation Protection) circuitry compensates for

overheating and overload to keep the amplifier working when others would fail.

Complete protection against shorted, open, and mismatched loads, overheating, DC, high-frequency overload, and full internal fault protection provided by our latest protection scheme: “Quad-Mute.”

Two mono modes (Bridge-Mono and Parallel-Mono) for driving a wide range of load impedances.

Dedicated power supply transformers iso- late channels in Stereo mode for superb crosstalk characteristics and reliability — each channel is virtually a separate amplifier.

High damping factor provides superior control over low-frequency drivers for a clean, accurate low end.

PIP (Programmable Input Processor) con- nector accepts accessories that tailor the amplifier to suit specific applications.

Enhanced PIP2™ (Programmable Input Processor) connector accepts new acces- sory modules that further tailor the ampli- fier to suit specific applications, including wideband load current monitoring.

Backed by the industry’s ONLY three-year, no-fault, fully transferable warranty.

2 How to Use This Manual

This manual provides you with the necessary information to safely and correctly set up and operate your amplifier. It does not cover every aspect of installation, setup or operation that might occur under every condition. For addi- tional information, please consult Crown’s Amplifier Application Guide (available online at www.crownaudio.com), Crown Technical Sup- port, your system installer or retailer.

We strongly recommend you read all instruc- tions, warnings and cautions contained in this manual. Also, for your protection, please send in your warranty registration card today. And save your bill of sale—it’s your official proof of purchase.

Operation Manual

page 5

Image 5
Contents Some models may be exported under the name Amcron Macro-Tech Watch for These Symbols Important Safety InstructionsCrown International, Inc Safety StandardTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents Welcome How to Use This ManualFeatures Unpack Your Amplifier Install Your Amplifier SetupYou may also stack amps without using a cabinet 48.3 cmChoose Output Wire and Con- nectors Choose Input Wire ConnectorsStereo Mode Wire Your SystemSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Precautions Startup ProcedureOperation Set Input SensitivitySignal/IOC Indicators Front Panel Controls and IndicatorsOdep Indicators Enable IndicatorStereo/Mono Switch Back Panel Controls, Indicators and Connec Tors Power CordInput Sensitivity Switch not shown Input Ground Lift SwitchIndicators IndicatorsStandby Mode Advanced Features OptionsProtection Systems OdepFuses and Circuit Breakers Advanced FeaturesHere are some of their many features PIP2 Adapter Connection Options PIP and PIP2 ModulesLevel Control Shaft Lock Cooling Fan OptionsTroubleshooting Theory of Operation Please refer to the block diagram in FigureOverview Circuit TheoryParallel-Mono Operation Bridge-Mono Operation120 VAC, 60 Hz Units, Parallel mono mode Specifications120 VAC, 60 Hz Units, Bridge mono mode Dimensions Width Power Draw at IdleWeight Net Weight Shipping WeightMacro-Tech 602 Maximum Power Matrix Maximum Power NotesMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Macro-Tech 602 Minimum Power Matrix Minimum Power NotesMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix Constant 0.35 is inefficiency 1.00-0.65 AC Power Draw andThermal DissipationAC Power Draw Thermal Dissipation Service United States & Canada Warranty12/01 Reason for failure, except as excluded in this WarrantyMA Series Power Amplifiers Crown Audio Factory Service Information