Crown Audio MA-602 Back Panel Controls, Indicators and Connec Tors Power Cord, Stereo/Mono Switch

Page 12

MA Series Power Amplifiers

4 Operation

4.3Back Panel Controls, Indicators and Connec-

tors

G. Power Cord

The power cord has an appropriate plug for the required voltage. 120 VAC, 60 Hz North American Macro-Tech 602s and 1202s have 14 AWG line cords and NEMA 5- 15P plugs. Macro-Tech 2402s have 12 AWG line cords and NEMA 5-20P plugs. International units are shipped with an appropriate line cord and plug. See Section 7 for AC power usage.

H. Stereo/Mono Switch

The three operating modes of a Macro-Tech amplifier are controlled by this switch. Stereo mode is used for nor- mal two-channel operation, Bridge-Mono mode is used to drive a single channel with a load impedance of at least 4 ohms, and Parallel-Mono mode is used to drive a single channel with an impedance less than 4 ohms. Important: Turn off the amplifier before changing the ste- reo/mono switch (see Sections 3.6.2 and 3.6.3).

I. Reset Switches (Macro-Tech 2402 only)

The Macro-Tech 2402 has a back panel Reset switch for each channel. Each switch resets the circuit breaker that protects the channel's power supply from overload.

J. PIP Module

The standard PIP2-FXQ is included with your amplifier. It provides female three-pin XLR input connectors. A vari- ety of other PIP modules can be used in place of the PIP2-FXQ. They add additional features that customize the amplifier for different applications (see Section 5.3.1 for information on available PIP modules).

Input Sensitivity Switch (not shown)

The three-position input sensitivity switch located inside the amplifier can be set after removing the PIP module

(J). It is set at the factory to 0.775 volts for standard 1- kHz output into 8 ohms. It can also be set to 1.4 volts for standard 1-kHz output into 8 ohms, or a fixed voltage gain of 26 dB (see Section 3.7).

K. Balanced Phone Jack Inputs

Balanced 1/4-inch phone jack input connectors are pro- vided on the PIP2-FXQ. The phone jacks can be wired for either balanced (tip, ring and sleeve) or unbalanced (tip and sleeve) input signals. Caution: The Channel 2 input should NOT be used in either Bridge-Mono or Parallel- Mono mode.

L. Balanced XLR Inputs

The factory-installed PIP2-FXQ provides a three-pin female XLR connector for balanced input to each chan- nel. The XLR inputs are connected in parallel with the amplifier's phone jack inputs. Because the PIP2-FXQ does not have any active circuitry, its XLR connectors can also be used as "daisy chain" outputs to connect sig- nals from phone jack inputs to multiple amplifiers. Cau- tion: The Channel 2 input should NOT be used in either Bridge-Mono or Parallel-Mono mode.

M. Output Jacks

Apair of versatile 5-way binding posts is provided for the output of each channel. The 5-way binding posts accept banana plugs, spade lugs or bare wire. (European models do not accept banana plugs.)

N. Input Ground Lift Switch

The input ground lift switch is located on the PIP2-FXQ. It is used to isolate the input signal grounds from the AC (chassis) ground to help prevent ground loops that can result in unwanted hum and noise (see the Crown Ampli- fier Application Guide for more information about pre- venting ground loops).

Figure 4.2 Rear Panel Controls & Connectors

(Note: Reset Switches (Item I) only available on the Macro-Tech 2402 model.)

page 12

Operation Manual

Image 12
Contents Macro-Tech Some models may be exported under the name AmcronImportant Safety Instructions Watch for These SymbolsSafety Standard Crown International, IncTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents How to Use This Manual FeaturesWelcome Setup Unpack Your Amplifier Install Your AmplifierYou may also stack amps without using a cabinet 48.3 cmChoose Input Wire Connectors Choose Output Wire and Con- nectorsWire Your System Stereo ModeSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Startup Procedure PrecautionsOperation Set Input SensitivityFront Panel Controls and Indicators Signal/IOC IndicatorsOdep Indicators Enable IndicatorBack Panel Controls, Indicators and Connec Tors Power Cord Stereo/Mono SwitchInput Sensitivity Switch not shown Input Ground Lift SwitchIndicators IndicatorsAdvanced Features Options Standby ModeProtection Systems OdepAdvanced Features Here are some of their many featuresFuses and Circuit Breakers Options PIP and PIP2 Modules PIP2 Adapter ConnectionCooling Fan Options Level Control Shaft LockTroubleshooting Please refer to the block diagram in Figure Theory of OperationOverview Circuit TheoryBridge-Mono Operation Parallel-Mono OperationSpecifications 120 VAC, 60 Hz Units, Bridge mono mode120 VAC, 60 Hz Units, Parallel mono mode Power Draw at Idle Dimensions WidthWeight Net Weight Shipping WeightMaximum Power Notes Macro-Tech 602 Maximum Power MatrixMacro-Tech 1202 Maximum Power Matrix Macro-Tech 2402 Maximum Power Matrix Minimum Power Notes Macro-Tech 602 Minimum Power MatrixMacro-Tech 1202 Minimum Power Matrix Macro-Tech 2402 Minimum Power Matrix AC Power Draw andThermal Dissipation Constant 0.35 is inefficiency 1.00-0.65AC Power Draw Thermal Dissipation Service Warranty United States & CanadaReason for failure, except as excluded in this Warranty 12/01MA Series Power Amplifiers Crown Audio Factory Service Information