Generac QT06024ANSX, QT06024AVAX Specifications, Generator, Engine, Cooling System, Fuel System

Page 10

Specifications

SPECIFICATIONS

GENERATOR

Type

Synchronous

Rotor Insulation

Class H

Stator Insulation

Class H

Telephone Interference Factor (TIF)

< 50

Alternator Output Leads 3-phase

4-wire

Bearings

Sealed Ball

Coupling

Flexible Disc

Load Capacity (Standby Rating)

60kW*

*NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural gas.

Excitation System

 

Direct

Generator Output Voltage/kW - 60 Hz

kW

Amp

CB Size

120/240V, 1-phase, 1.0 pf

60

250

300

120/208V, 3-phase, 0.8 pf

60

208

250

120/240V, 3-phase, 0.8 pf

60

180

200

277/480V, 3-phase, 0.8 pf

60

90

100

Generator Locked Rotor KVA Available @ Voltage Dip of 35%

Single-phase or 208, 3-phase (60kW)

......................

120 KVA

480V, 3-phase (60kW)

 

141 KVA

ENGINE

Make

Generac

Model

In Line

Cylinders and Arrangement

4

Displacement

2.4 Liter

Bore

3.41 in.

Stroke

3.94 in.

Compression Ratio

9.5-to-1

Air Intake System

Turbo Charged/After Cooled

Valve Seats

Hardened

Lifter Type

Hydraulic

Spark Plug Gap

0.17mm (0.028 inch)

Engine Parameters

 

 

Rated Synchronous RPM

60 Hz, 3600

Exhaust System

 

 

Exhaust Flow at Rated Output 60 Hz (60kW)

494 cfm

Exhaust Temp. at Rated Output (60kW)

1050° F

Combustion Air Requirements (Natural Gas)

 

Flow at rated power, 60 Hz (60kW)

180 cfm

Governor

 

 

Type

Electronic

Frequency Regulation

Isochronous

Steady State Regulation

± 0.25%

Engine Lubrication System

 

Type of Oil Pump

Gear

Oil Filter

Full Flow Spin-on, Cartridge

Crankcase Oil Capacity ....5.25 U.S. qts. (including filter capacity)

COOLING SYSTEM

Type

Pressurized Closed Recovery

Water Pump

Belt Driven

Fan Speed

2050 rpm

Fan Diameter

22 inches

Fan Mode

Puller

Air Flow (inlet air including.................................................alternator and

3280 ft3/min.

combustion air)

 

Coolant Capacity

(2.5 U.S. gal.)

Heat Rejection to Coolant (60kW)

270,000 Btu/h

Maximum Operating Air Temp. on Radiator

60° C (150° F)

Maximum Ambient Temperature

50° C (140° F)

FUEL SYSTEM

Type of Fuel

Natural Gas, Propane Vapor

Carburetor

 

Down Draft

Secondary Fuel Regulator

 

Standard

Fuel Shut-off Solenoid

 

Standard

Operating Fuel Pressure

5 in. - 14 in. Water Column

Fuel Consumption - ft3/hr (Natural Gas/LPV)

 

 

Exercise

25%

50%

75%

100%

 

Cycle

Load

Load

Load

Load

60kW

123/49.3

267/101

483/183

672/255

862/327

ELECTRICAL SYSTEM

 

 

 

Battery Charge Alternator

12V, 30 Amp

Static Battery Charger

 

2.5 Amp

Recommended Battery

Group 26, 525CCA

System Voltage

 

 

12 Volts

Voltage Regulator

 

 

 

Type

 

 

 

Electronic

Sensing

................................................................

 

Single-phase

Regulation

 

 

± 1%

Features

Adjustable Voltage and Gain

Power Adjustment for Ambient Conditions

 

Temperature Deration

 

 

 

3% for every 10° C above °C (60kW)

25

1.65% for every 10° above °F (60kW)

77

Altitude Deration

 

 

 

 

1% for every 100 m above m (60kW)

915

3% for every 1000 ft. above ft. (60kW)

3000

Controller

 

 

Nexus

6-1

05/10 A .Rev GenSpec088

Image 10
Contents Stationary Emergency Generator Table of Contents Introduction Operation and MaintenanceHOW to Obtain Service Read this Manual ThoroughlySafety Rules General HazardsFire Hazards Identification Record Data LabelEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices Natural GAS Fuel System Fuel RequirementsPropane Vapor Withdrawal Fuel System Engine SpecificationsGenerator Cooling SystemWeather and Maintenance Kits Phase Alternators Y Configuration Alternator Power Winding ConnectionsFOUR-LEAD, SINGLE-PHASE Stator Alternator AC Lead ConnectionsStator Power Winding Connections 3-phase, 120/208V 6 Lead Using the AUTO/OFF/MANUAL Switch Control Panel InterfaceActivation Chart Choose Language TroubleshootingLOW Speed Exercise Automatic Transfer OperationOverspeed Shutdown Alarm LOW OIL Pressure Shutdown AlarmOvercrank Shutdown Alarm RPM Sensor Failure Shutdown AlarmLOW Battery Warning UNDER-FREQUENCY Shutdown AlarmLOW Battery Alarm Missing CAM Pulse AlarmCanbus Alarm Overvoltage AlarmInternal Failure Shutdown Alarm Ignition AlarmMaintenance Alert Chart Condition CheryPanel Stationary Emergency Generator Control and Operation Operating Unit with Manual Transfer SwitchOperating Unit with Automatic Transfer Switch Engine START-UP and TransferChanging Engine OIL General MaintenanceCheck Engine OIL Cooling INTAKE/OUTLETOverload Protection for Engine DC Electrical System Engine CoolantCoolant Change Exercise SystemBattery Fluid Battery MaintenanceBattery Replacement Spark PlugsService Schedule System / Component Frequency ProcedureTroubleshooting Guide Problem Cause CorrectionPage Assy STR 390 25GD3 CPL Page Page Page Group a UL Circuit Breaker 225AF UL Circuit Breaker KG Group a This page Left Intentionally Blank Page NUT Flanged HEX M12-1.75 Page Battery TRAY, C1 & C2 Page Group D Page Page Weldment Radiator Support C2 Page Page Exploded View Turbo 2.4L G2 Page Group F Page Page Drawing #0H7323 COIL-2.4L G2 Ignition Page Flange Fuel Inlet Page FLANGE, Fuel Inlet Page Rear Wrap C2 G2 60KW Page Page Page Page Page Page Page Page Page Page Page Page Page Page 04/07 a .Rev BackPg001

QT06024ANAX, QT06024AVSX, QT06024ANSX, QT06024AVAX specifications

The Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are powerful and versatile residential generators designed for those who want the peace of mind provided by reliable backup power. These models from Generac's Guardian Series are engineered for performance, efficiency, and ease of use, making them ideal solutions for homeowners looking to ensure uninterrupted power during outages.

One of the standout features of these generators is their robust 60 kW capacity, which allows them to power essential home appliances, HVAC systems, and even larger electricity-demanding devices without a hitch. This capacity makes them suitable for medium to large homes, providing enough energy to keep daily operations running smoothly even during extended outages.

The QT series incorporates Generac's advanced Quiet-Test technology, which reduces noise levels during self-testing. This feature enables the generator to perform regular self-diagnostic tests at a much quieter decibel level, ensuring it does not disrupt the household during these checks. Additionally, the generators are designed with a weather-resistant enclosure, providing durability and protection against various environmental conditions.

The models are equipped with an intuitive control panel featuring a user-friendly digital display that allows for easy monitoring of power usage and system status. They also feature an automatic transfer switch that seamlessly switches from grid power to generator power in case of an outage, ensuring that the transition is almost instantaneous and worry-free for homeowners.

Moreover, the QT series generators utilize a liquid-cooled engine, which provides greater efficiency and performance compared to air-cooled alternatives. This technology not only ensures longer run times but also contributes to a longer lifespan for the generator. The low-oil pressure shutdown feature is another critical safety aspect, protecting the engine from damage by automatically shutting it down when oil levels are too low.

Finally, these models are designed with flexibility in mind. They can be customized with various accessories and options to meet specific homeowner needs. Whether for full home backup or partial power, the Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are reliable solutions that give homeowners the confidence to weather any storm without losing power. With their combination of advanced technology, powerful performance, and user-friendly features, Generac continues to set the standard in home standby power solutions.