Generac QT06024ANSX, QT06024AVAX, QT06024ANAX, QT06024AVSX owner manual Table of Contents

Page 2

Table of Contents

SECTION

PAGE

Alarm and Warning Messages

8-4

INTRODUCTION

1-1

Low Oil Pressure Shutdown Alarm

8-4

Read this Manual Thoroughly

1-1

High Coolant Temperature Shutdown Alarm

8-4

Operation and Maintenance

1-1

Overcrank Shutdown Alarm

8-4

How to Obtain Service

1-1

Overspeed Shutdown Alarm

8-4

SAFETY RULES

1-2

RPM Sensor Failure Shutdown Alarm

8-4

GENERAL INFORMATION

2-1

Under-frequency Shutdown Alarm

8-5

Identification Record

2-1

Low Battery Alarm

8-5

Data Label

2-1

Low Battery Warning

8-5

EQUIPMENT DESCRIPTION

3-1

Low Coolant Level Alarm

8-5

Equipment Description

3-1

Missing Cam Pulse Alarm

8-5

Engine Oil Recommendations

3-1

Missing Crank Pulse Alarm

8-5

Coolant Recommendations

3-1

Low Fuel Pressure Warning

8-5

ENGINE PROTECTIVE DEVICES

4-1

Governor Sensor Fault Alarm

8-5

Engine Protective Devices

4-1

Wiring Error Alarm

8-5

High Coolant Temperature Sender

4-1

Undervoltage Alarm

8-5

Low Coolant Level Sensor

4-1

Overvoltage Alarm

8-6

Low Oil Pressure Switch

4-1

Internal Failure Shutdown Alarm

8-6

Overcrank Shutdown

4-1

Canbus Alarm

8-6

Overspeed Shutdown

4-1

Ignition Alarm

8-6

RPM Sensor Loss Shutdown

4-1

Maintenance Warning

8-6

DC Fuses

4-1

Alarm Cancel

8-6

FUEL SYSTEM

5-1

Common Alarm Relay

8-6

Fuel Requirements

5-1

Maintenance Alerts

8-6

Natural Gas Fuel System

5-1

Menu System

8-7

Propane Vapor Withdrawal Fuel System

5-1

OPERATION

9-1

LP Liquid Fuel System

5-1

Stationary Emergency Generator Control and Operation

9-1

SPECIFICATIONS

6-1

Operating Unit with Manual Transfer Switch

9-1

Stationary Emergency Generator

6-1

Engine Start-up and Transfer

9-1

Engine

6-1

Retransfer and Shutdown

9-1

Cooling System

6-1

Operating Unit with Automatic Transfer Switch

9-1

Fuel System

6-1

MAINTENANCE

10-1

Electrical System

6-1

General Maintenance

10-1

Weather and Maintenance Kits

6-2

Check Engine Oil

10-1

Reconfiguring the Fuel System

6-2

Changing Engine Oil

10-1

Fuel System

6-2

Cooling Intake/Outlet

10-1

Control Panel

6-2

Inspect Cooling System

10-1

GENERAL INFORMATION

7-1

Engine Coolant

10-2

Alternator AC Lead Connections

7-1

Coolant Change

10-2

Four-lead, Single-phase Stator

7-1

Overload Protection for Engine DC Electrical System

10-2

Alternator Power Winding Connections

7-1

Exercise System

10-2

3-phase Alternators ("Y" Configuration)

7-1

Perform Visual Inspection

10-2

3-phase Alternators ("Delta" Configuration)

7-2

Inspect Exhaust System

10-2

CONTROL PANEL

8-1

Check Fan Belt

10-2

Control Panel Interface

8-1

Inspect Engine Governor

10-2

Using the Auto/Off/Manual Switch

8-1

Changing the Engine Air Filter

10-2

Activate the Generator

8-1

Spark Plugs

10-3

Display Interface Menus

8-1

Battery Maintenance

10-3

Activation Chart

8-2

Battery Replacement

10-3

Setting the Exercise Timer

8-3

Battery Fluid

10-3

Low Speed Exercise

8-3

Cleaning the Stationary Emergency Generator

10-3

User Adjustable Settings

8-3

SERVICE SCHEDULE

11-1

Fuel Conversion

8-3

TROUBLESHOOTING

12-1

Operation

8-3

Troubleshooting Guide

12-1

Automatic Transfer Operation

8-3

EMISSIONS WARRANTY

13-1

Sequence of Automatic Operation

8-4

NOTES

 

Crank Cycles and Overcrank Shutdown

8-4

EXPLODED VIEWS & PARTS LISTS

 

Auto Start

8-4

WIRING DIAGRAMS & SCHEMATICS

 

Manual Start

8-4

 

 

05/10 A .Rev Content048

Image 2
Contents Stationary Emergency Generator Table of Contents Introduction Operation and MaintenanceHOW to Obtain Service Read this Manual ThoroughlySafety Rules General HazardsFire Hazards Identification Record Data LabelCoolant Recommendations Equipment DescriptionEngine OIL Recommendations Engine Protective Devices Propane Vapor Withdrawal Fuel System Fuel RequirementsNatural GAS Fuel System Engine SpecificationsGenerator Cooling SystemWeather and Maintenance Kits Phase Alternators Y Configuration Alternator Power Winding ConnectionsFOUR-LEAD, SINGLE-PHASE Stator Alternator AC Lead ConnectionsStator Power Winding Connections 3-phase, 120/208V 6 Lead Using the AUTO/OFF/MANUAL Switch Control Panel InterfaceActivation Chart Choose Language TroubleshootingLOW Speed Exercise Automatic Transfer OperationOverspeed Shutdown Alarm LOW OIL Pressure Shutdown AlarmOvercrank Shutdown Alarm RPM Sensor Failure Shutdown AlarmLOW Battery Warning UNDER-FREQUENCY Shutdown AlarmLOW Battery Alarm Missing CAM Pulse AlarmCanbus Alarm Overvoltage AlarmInternal Failure Shutdown Alarm Ignition AlarmMaintenance Alert Chart Condition CheryPanel Stationary Emergency Generator Control and Operation Operating Unit with Manual Transfer SwitchOperating Unit with Automatic Transfer Switch Engine START-UP and TransferChanging Engine OIL General MaintenanceCheck Engine OIL Cooling INTAKE/OUTLETOverload Protection for Engine DC Electrical System Engine CoolantCoolant Change Exercise SystemBattery Fluid Battery MaintenanceBattery Replacement Spark PlugsService Schedule System / Component Frequency ProcedureTroubleshooting Guide Problem Cause CorrectionPage Assy STR 390 25GD3 CPL Page Page Page Group a UL Circuit Breaker 225AF UL Circuit Breaker KG Group a This page Left Intentionally Blank Page NUT Flanged HEX M12-1.75 Page Battery TRAY, C1 & C2 Page Group D Page Page Weldment Radiator Support C2 Page Page Exploded View Turbo 2.4L G2 Page Group F Page Page Drawing #0H7323 COIL-2.4L G2 Ignition Page Flange Fuel Inlet Page FLANGE, Fuel Inlet Page Rear Wrap C2 G2 60KW Page Page Page Page Page Page Page Page Page Page Page Page Page Page 04/07 a .Rev BackPg001

QT06024ANAX, QT06024AVSX, QT06024ANSX, QT06024AVAX specifications

The Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are powerful and versatile residential generators designed for those who want the peace of mind provided by reliable backup power. These models from Generac's Guardian Series are engineered for performance, efficiency, and ease of use, making them ideal solutions for homeowners looking to ensure uninterrupted power during outages.

One of the standout features of these generators is their robust 60 kW capacity, which allows them to power essential home appliances, HVAC systems, and even larger electricity-demanding devices without a hitch. This capacity makes them suitable for medium to large homes, providing enough energy to keep daily operations running smoothly even during extended outages.

The QT series incorporates Generac's advanced Quiet-Test technology, which reduces noise levels during self-testing. This feature enables the generator to perform regular self-diagnostic tests at a much quieter decibel level, ensuring it does not disrupt the household during these checks. Additionally, the generators are designed with a weather-resistant enclosure, providing durability and protection against various environmental conditions.

The models are equipped with an intuitive control panel featuring a user-friendly digital display that allows for easy monitoring of power usage and system status. They also feature an automatic transfer switch that seamlessly switches from grid power to generator power in case of an outage, ensuring that the transition is almost instantaneous and worry-free for homeowners.

Moreover, the QT series generators utilize a liquid-cooled engine, which provides greater efficiency and performance compared to air-cooled alternatives. This technology not only ensures longer run times but also contributes to a longer lifespan for the generator. The low-oil pressure shutdown feature is another critical safety aspect, protecting the engine from damage by automatically shutting it down when oil levels are too low.

Finally, these models are designed with flexibility in mind. They can be customized with various accessories and options to meet specific homeowner needs. Whether for full home backup or partial power, the Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are reliable solutions that give homeowners the confidence to weather any storm without losing power. With their combination of advanced technology, powerful performance, and user-friendly features, Generac continues to set the standard in home standby power solutions.