Generac QT06024AVSX, QT06024AVAX, QT06024ANAX, QT06024ANSX owner manual Group D

Page 43

EXPLODED VIEW: AIR CLEANER 2.4L G2 TURBO

DRAWING #: 0H1954

APPLICABLE TO:

GROUP D

ITEM

PART#

QTY.

DESCRIPTION

 

 

 

 

1

0F4269

2

GASKET MIXER BODY

2

0H0030

1

ADAPTOR-MIXER

3

0G39340ST03

1

BRACKET AIR INTAKE

4

035480

1

BOLT U 5/16-18 X 2.06

5

0H0028

1

ADAPTOR-AIR CLEANER

6

0F4271

1

BASE PLATE, AIR CLEANER

7

0H0219

1

PLUG PLASTIC 2.5" BLACK

8

0F5418

1

ELEMENT AIR FILTER

9

0F4270

1

HOLD DOWN AIR CLEANER PLATED

10

0F6323

1

PLATE, AIR CLEANER TOP

11

0H0035

1

HOSE AIR INTAKE

12

0G0153

1

BARBED EL 90 1/2NPT X 3/4 HOSE

13

0D3700

4

NUT FLANGE M6-1.0 NYLOK

14

049811

8

WASHER, FLAT, M6

15

045757

4

SCREW HHC M6-1.0 X 25 G8.8

16

022097

4

WASHER LOCK M6-1/4

17

047411

4

SCREW HHC M6-1.0 X 16 C8.8

18

022145

2

WASHER FLAT 5/16-M8 ZINC

19

022129

2

WASHER LOCK M8-5/16

20

039253

2

SCREW HHC M8-1.25 X 20 G8.8

21

037561

1

NUT WING 1/4-20 W/NY INS ST ZN

22

0D3700

4

NUT FLANGE M6-1.0 NYLOK

23

049811

8

WASHER, FLAT, M6

24

045757

4

SCREW HHC M6-1.0 X 25 G8.8

25

022097

4

WASHER LOCK M6-1/4

26

047411

4

SCREW HHC M6-1.0 X 16 C8.8

27

086133C

2

CLAMP HI TORQUE 1.75 - 2.625

28

039253

2

SCREW HHC M8-1.25 X 20 G8.8

29

022129

4

WASHER LOCK M8-5/16

30

022145

4

WASHER FLAT 5/16-M8 ZINC

31

022259

2

NUT HEX 5/16-18 STEEL

32

0H1712

1

BARBED EL-90 POLY 1/2NPT X ¾

33

057822

2

CLAMP HOSE #8 .53-1.00

34

059057

1

HOSE 3/4 ID SAE-30R2 (7.62”LG”)

35

0H0027

1

FITTING VENT VALVE COVER 2.4L

 

047527(3)(4)

1

BARBED STR 1/2NPT X 3/4

 

0H1644(4)

1

FTG VNT VALVE COVER

 

0G10080103(4)

1(REF)

GASKET, PCV VALVE

36(1)(2)

0H1787A

1

PIPE INSULATION ELBO

37(2)

0H1787

1

PIPE INSULATION (4.5”LG)

38(2)

0H1801

1

PIPE INSULATION TAPE (7”LG)

(1)TRIM PIPE INSULATION ELBOW TO FIT.

(2)INSULATION SHALL COMPLETELY COVER I/N’S 32, 34 & 35.

(3)APPLY PIPE SEALANT COMPOUND TO THREADS.

(4) ALTERNATE CONFIGURATION REQUIRES ALL NOTED PARTS.

NOTE: APPLY LOCTITE 620 BEARING RETAINMENT COMPOUND TO OUTSIDE

SURFACE OF FITTING (I/N 35) THAT PRESSES INTO VALVE COVER.

REVISION: H-3963 –B

PAGE 2 OF 2

DATE: 2/27/09

 

Image 43
Contents Stationary Emergency Generator Table of Contents Read this Manual Thoroughly Operation and MaintenanceHOW to Obtain Service IntroductionGeneral Hazards Safety RulesFire Hazards Data Label Identification RecordEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices Natural GAS Fuel System Fuel RequirementsPropane Vapor Withdrawal Fuel System Cooling System SpecificationsGenerator EngineWeather and Maintenance Kits Alternator AC Lead Connections Alternator Power Winding ConnectionsFOUR-LEAD, SINGLE-PHASE Stator Phase Alternators Y ConfigurationStator Power Winding Connections 3-phase, 120/208V 6 Lead Control Panel Interface Using the AUTO/OFF/MANUAL SwitchChoose Language Troubleshooting Activation ChartAutomatic Transfer Operation LOW Speed ExerciseRPM Sensor Failure Shutdown Alarm LOW OIL Pressure Shutdown AlarmOvercrank Shutdown Alarm Overspeed Shutdown AlarmMissing CAM Pulse Alarm UNDER-FREQUENCY Shutdown AlarmLOW Battery Alarm LOW Battery WarningIgnition Alarm Overvoltage AlarmInternal Failure Shutdown Alarm Canbus AlarmCondition Chery Maintenance Alert ChartPanel Engine START-UP and Transfer Operating Unit with Manual Transfer SwitchOperating Unit with Automatic Transfer Switch Stationary Emergency Generator Control and OperationCooling INTAKE/OUTLET General MaintenanceCheck Engine OIL Changing Engine OILExercise System Engine CoolantCoolant Change Overload Protection for Engine DC Electrical SystemSpark Plugs Battery MaintenanceBattery Replacement Battery FluidSystem / Component Frequency Procedure Service ScheduleProblem Cause Correction Troubleshooting GuidePage Assy STR 390 25GD3 CPL Page Page Page Group a UL Circuit Breaker 225AF UL Circuit Breaker KG Group a This page Left Intentionally Blank Page NUT Flanged HEX M12-1.75 Page Battery TRAY, C1 & C2 Page Group D Page Page Weldment Radiator Support C2 Page Page Exploded View Turbo 2.4L G2 Page Group F Page Page Drawing #0H7323 COIL-2.4L G2 Ignition Page Flange Fuel Inlet Page FLANGE, Fuel Inlet Page Rear Wrap C2 G2 60KW Page Page Page Page Page Page Page Page Page Page Page Page Page Page 04/07 a .Rev BackPg001

QT06024ANAX, QT06024AVSX, QT06024ANSX, QT06024AVAX specifications

The Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are powerful and versatile residential generators designed for those who want the peace of mind provided by reliable backup power. These models from Generac's Guardian Series are engineered for performance, efficiency, and ease of use, making them ideal solutions for homeowners looking to ensure uninterrupted power during outages.

One of the standout features of these generators is their robust 60 kW capacity, which allows them to power essential home appliances, HVAC systems, and even larger electricity-demanding devices without a hitch. This capacity makes them suitable for medium to large homes, providing enough energy to keep daily operations running smoothly even during extended outages.

The QT series incorporates Generac's advanced Quiet-Test technology, which reduces noise levels during self-testing. This feature enables the generator to perform regular self-diagnostic tests at a much quieter decibel level, ensuring it does not disrupt the household during these checks. Additionally, the generators are designed with a weather-resistant enclosure, providing durability and protection against various environmental conditions.

The models are equipped with an intuitive control panel featuring a user-friendly digital display that allows for easy monitoring of power usage and system status. They also feature an automatic transfer switch that seamlessly switches from grid power to generator power in case of an outage, ensuring that the transition is almost instantaneous and worry-free for homeowners.

Moreover, the QT series generators utilize a liquid-cooled engine, which provides greater efficiency and performance compared to air-cooled alternatives. This technology not only ensures longer run times but also contributes to a longer lifespan for the generator. The low-oil pressure shutdown feature is another critical safety aspect, protecting the engine from damage by automatically shutting it down when oil levels are too low.

Finally, these models are designed with flexibility in mind. They can be customized with various accessories and options to meet specific homeowner needs. Whether for full home backup or partial power, the Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are reliable solutions that give homeowners the confidence to weather any storm without losing power. With their combination of advanced technology, powerful performance, and user-friendly features, Generac continues to set the standard in home standby power solutions.