Generac QT06024ANAX, QT06024AVAX, QT06024ANSX, QT06024AVSX owner manual Assy STR 390 25GD3 CPL

Page 29

1

0F9677

1

ROTOR-2390-45KD1 CPL

 

0G0056

1

ROTOR-2390-35KD1 CPL

 

0G0959

1

ROTOR-2390-45KD1 CPL (G2)

 

0G1155

1

ROTOR-2390-35KD1 CPL (G2)

 

0G1931

1

ROTOR 25KW 3PH DIRECT 390 1800

 

0G2101

1

ROTOR 25KW 1PH DIRECT 390 1800

 

0G3734

1

RTR-2390-60KD2 CPL

 

0G6562

1

RTR 390 35AD1 CPL

 

0G6564

1

RTR 390 35KD1 CPL

2

0F9664

1

STATOR-390 45K 2P 1PH DIRECT

 

0G0057

1

STATOR-2390-35AD1 CPL

 

0G0058

1

STATOR-2390-35KD1 CPL

 

0G0059

1

STATOR-2390-35GD1 CPL

 

0G0183

1

STATOR-2309-45KW 2P 3PH 208V

 

0G0184

1

STATOR-2309-45-KD1 CPL

 

0G1932

1

ASSY STR 390 25GD3 CPL

 

0G2098

1

ASSY STR 390 25AD1 CPL

 

0G2099

1

ASSY STR 390 25KD3 CPL

 

0G2100

1

ASSY STR 390 25JD3 CPL

 

0G3736

1

ASSY STR 2390 60AD2 CPL

 

0G3737

1

ASSY STR 390 60KW 2P 3PH 208V

 

0G3738

1

ASSY STR 390 60KW 2P 3PH 480V

 

0G6104

1

STR-2390--45JD1 CPL

 

0G6563

1

STR 390 35AD1 CPL

 

0G6565

1

STR 390 35GD1 CPL

 

0G6566

1

STR 390 35KD1 CPL

 

0G6567

1

STR 390 35JD1 CPL

 

0H0201

1

STR-2390--60JD2 CPL

 

0H1299

1

ASSY STR 390 36AD1 CPL

 

0H1300

1

ASSY STR 390 36JD1 CPL

 

0H1301

1

ASSY STR 390 36 GD1 CPL

3

0C9708

REF

INSTR HYPOT TEST (NOT SHOWN)

4

SEE ENGINE EV

REF

ENGINE ADAPTER

5

SEE ENGINE EV

REF

FLEXPLATE

6

0F5767B

1

ASSY FLYWHEEL CPL W/40MM FAN B

7

0E5706

1

REAR BEARING CARRIER 390/DRCT

8

0F7874

1

ASSY BRUSH HOLDER 390/HSB

 

0F7874A

1

ASSY BRUSH HOLDER 390/HSB

9

0G0587

1

GUARD REAR BEARING CARRIER

10

038150

4

WASHER FLAT #8 ZINC

11

023454

1

KEY WOODRUFF #E

12

077043E

1

CONDUIT FLEX 1.0" ID (35” LG)

13

04576100BU

4

STUD M14-2.0 570 G5 ZINC

14

052646

4

WASHER FLAT M14

15

043123

4

WASHER LOCK M14

16

051779

4

NUT HEX M14-2.0 G8 YEL CHR

17

0A2601

1

SCREW HHC M16-2.0 X 45 G8.8

18

072879

1

SPACER .69 X 2.75 X .37 ST/ZNC

19

0F8408

4

SCREW HHC M10-1.50 X 16 G10.9

20

046526

4

WASHER LOCK M10

21

0C3992

4

SCREW HHTT M4-0.7 X 16 BP

22

022264

4

WASHER LOCK #8-M4

23 *

047248

1

BALL BEARING-45 MM

24 *

070892

1

SLIP RING MACHINED

25

0G0588

1

GUARD REAR BEARING CARRIER

26

077043A

1

CONDUIT FLEX .38" ID (60”)

27

056326

1

TRIM VINYL BLACK 1/8GP (16.5”LG)

* ROTOR REPLACEMENT PARTS

Image 29
Contents Stationary Emergency Generator Table of Contents HOW to Obtain Service Operation and MaintenanceIntroduction Read this Manual ThoroughlyGeneral Hazards Safety RulesFire Hazards Data Label Identification RecordCoolant Recommendations Equipment DescriptionEngine OIL Recommendations Engine Protective Devices Propane Vapor Withdrawal Fuel System Fuel RequirementsNatural GAS Fuel System Generator SpecificationsEngine Cooling SystemWeather and Maintenance Kits FOUR-LEAD, SINGLE-PHASE Stator Alternator Power Winding ConnectionsPhase Alternators Y Configuration Alternator AC Lead ConnectionsStator Power Winding Connections 3-phase, 120/208V 6 Lead Control Panel Interface Using the AUTO/OFF/MANUAL SwitchChoose Language Troubleshooting Activation ChartAutomatic Transfer Operation LOW Speed ExerciseOvercrank Shutdown Alarm LOW OIL Pressure Shutdown AlarmOverspeed Shutdown Alarm RPM Sensor Failure Shutdown AlarmLOW Battery Alarm UNDER-FREQUENCY Shutdown AlarmLOW Battery Warning Missing CAM Pulse AlarmInternal Failure Shutdown Alarm Overvoltage AlarmCanbus Alarm Ignition AlarmCondition Chery Maintenance Alert ChartPanel Operating Unit with Automatic Transfer Switch Operating Unit with Manual Transfer SwitchStationary Emergency Generator Control and Operation Engine START-UP and TransferCheck Engine OIL General MaintenanceChanging Engine OIL Cooling INTAKE/OUTLETCoolant Change Engine CoolantOverload Protection for Engine DC Electrical System Exercise SystemBattery Replacement Battery MaintenanceBattery Fluid Spark PlugsSystem / Component Frequency Procedure Service ScheduleProblem Cause Correction Troubleshooting GuidePage Assy STR 390 25GD3 CPL Page Page Page Group a UL Circuit Breaker 225AF UL Circuit Breaker KG Group a This page Left Intentionally Blank Page NUT Flanged HEX M12-1.75 Page Battery TRAY, C1 & C2 Page Group D Page Page Weldment Radiator Support C2 Page Page Exploded View Turbo 2.4L G2 Page Group F Page Page Drawing #0H7323 COIL-2.4L G2 Ignition Page Flange Fuel Inlet Page FLANGE, Fuel Inlet Page Rear Wrap C2 G2 60KW Page Page Page Page Page Page Page Page Page Page Page Page Page Page 04/07 a .Rev BackPg001

QT06024ANAX, QT06024AVSX, QT06024ANSX, QT06024AVAX specifications

The Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are powerful and versatile residential generators designed for those who want the peace of mind provided by reliable backup power. These models from Generac's Guardian Series are engineered for performance, efficiency, and ease of use, making them ideal solutions for homeowners looking to ensure uninterrupted power during outages.

One of the standout features of these generators is their robust 60 kW capacity, which allows them to power essential home appliances, HVAC systems, and even larger electricity-demanding devices without a hitch. This capacity makes them suitable for medium to large homes, providing enough energy to keep daily operations running smoothly even during extended outages.

The QT series incorporates Generac's advanced Quiet-Test technology, which reduces noise levels during self-testing. This feature enables the generator to perform regular self-diagnostic tests at a much quieter decibel level, ensuring it does not disrupt the household during these checks. Additionally, the generators are designed with a weather-resistant enclosure, providing durability and protection against various environmental conditions.

The models are equipped with an intuitive control panel featuring a user-friendly digital display that allows for easy monitoring of power usage and system status. They also feature an automatic transfer switch that seamlessly switches from grid power to generator power in case of an outage, ensuring that the transition is almost instantaneous and worry-free for homeowners.

Moreover, the QT series generators utilize a liquid-cooled engine, which provides greater efficiency and performance compared to air-cooled alternatives. This technology not only ensures longer run times but also contributes to a longer lifespan for the generator. The low-oil pressure shutdown feature is another critical safety aspect, protecting the engine from damage by automatically shutting it down when oil levels are too low.

Finally, these models are designed with flexibility in mind. They can be customized with various accessories and options to meet specific homeowner needs. Whether for full home backup or partial power, the Generac QT06024AVAX, QT06024ANSX, QT06024AVSX, and QT06024ANAX are reliable solutions that give homeowners the confidence to weather any storm without losing power. With their combination of advanced technology, powerful performance, and user-friendly features, Generac continues to set the standard in home standby power solutions.