Generac 004583-0 owner manual To Start the Engine, Adding Gasoline

Page 13

Section 2 – Operation

Residential Portable Generator System

2.6.2 ADDING GASOLINE

------------- WARNING -------------

WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank.

Caution: Do not overfill the fuel tank. Always leave room for fuel expansion.

Use regular UNLEADED gasoline with the generator engine. Do not use premium gasoline. Do not mix oil with gasoline.

Clean area around fuel fill cap, remove cap.

Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill. Allow about 1/2" of tank space for fuel expansion, as shown here.

Install fuel cap and wipe up any spilled gasoline.

Figure 14 - Fuel Tank

IMPORTANT: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See "Storage" on page 18. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

2.7 TO START THE ENGINE

WARNING: Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

Unplug all electrical loads from the unit's receptacles before starting the engine.

Make sure the unit is in a level position.

Open the fuel shut-off valve.

Figure 15 - Fuel Shut-off Valve

Locate the Idle Control ON/OFF switch on the control panel and set it to the “OFF” position.

Figure 16 - Idle Control Switch

11

Image 13
Contents Authorized Dealer Support Owner’s ManualTroubleshooting Table of Contents Residential Portable Generator SystemRead this Manual Thoroughly Never operate in an enclosed area or indoors General HazardsExplosion Hazards Electrical HazardsFire Hazards Unpacking Accessory BOXAssembling the Wheel KIT Assembling the HandleHandle Assembly Battery ConnectionKnow the Generator 1 AC, 20 AMP, Duplex Receptacle Cord Sets and Connection Plugs2 120V AC, 20 AMP, Gfci Receptacle Provided. This receptacle can not recharge 6 Volt batteries 5 12 Volt DC, 10 AMP ReceptacleConnecting Electrical Loads HOW to USE the GeneratorDON’T Overload the Generator Grounding the GeneratorBefore Starting the Generator Wattage Reference GuideAdding Engine OIL Adding Gasoline To Start the EngineLOW OIL Pressure Shutdown System Automatic Idle ControlStopping the Engine To recharge 12 Volt batteries, proceed as follows Charging a BatteryMaintenance Residential Portable Generator System Maintenance ScheduleEngine Maintenance Checking OIL Level Generator MaintenanceTo Clean the Generator General RecommendationsClean Spark Arrestor Screen Service AIR CleanerReplacing the Spark Plug To adjust valve clearance Adjusting Valve ClearanceLong Term Storage GeneralOther Storage Tips Troubleshooting KIT Includes Installation for Manual Transfer SwitchTools Required Items YOU Must PurchaseSilicone Caulk These Instructions are to Serve AS a Guide only7a Prepare Box For Connections Connection of Emergency Circuits Operation of Generator with Manual Transfer Switch Using the Ultra Source PortableTransfer to Generator Power Source When Utility Power Fails Transfer Back to Utility Power SourceInterconnection Drawing Residential Portable Generator System Engine Wiring Closest to Bearing Schematic, UltraSource Portable Generator Drawing No G0733 Wiring Diagram, Manual Transfer Switch Drawing No G1065 Manual Transfer Switch with Load Center Drawing No G0939-B Description Exploded Views and Parts ListsSystem 160QTY Description Lists 118 116 119162QTY Description Part NO# Generator Drawing No D4488-F QTY Description Control Panel Drawing No G0727-B Part NO. QTY Description Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule

004583-0 specifications

Generac 004583-0 is a powerful and efficient home standby generator designed to provide reliable backup power during outages. This unit is specifically engineered to ensure that homeowners never have to worry about the disruption caused by power loss, keeping essential appliances and systems running smoothly, regardless of external conditions.

At the heart of the Generac 004583-0 is its robust engine, which delivers a peak output of 22 kW and is capable of running on either propane or natural gas. This fuel flexibility makes it an ideal choice for a variety of households, allowing users to select the fuel source that best fits their needs. The generator employs a high-performance, air-cooled engine featuring a durable construction that ensures long-lasting operation, and this reliability translates into peace of mind for homeowners.

One of the standout features of the Generac 004583-0 is its advanced Automatic Transfer Switch (ATS). The ATS seamlessly detects power outages and automatically switches the home’s electrical supply to the generator within seconds. This quick response is crucial for maintaining comfort and safety, especially during extreme weather conditions. The ATS also offers customizable settings, allowing homeowners to prioritize which circuits they want to power during an outage.

In addition to its seamless operation, the Generac 004583-0 integrates innovative technologies such as Mobile Link. This feature enables users to monitor the generator remotely via a smartphone app, providing real-time updates on the system’s status and maintenance needs. This connectivity enhances user experience and simplifies the management of the generator.

The generator is designed with a noise-reduction enclosure, ensuring that it operates quietly without disturbing daily life or neighborhood peace. Furthermore, the unit is built to withstand various weather conditions, featuring corrosion-resistant materials that ensure durability and a long service life.

Safety is paramount, and the Generac 004583-0 incorporates various safety features such as low oil and high-temperature shut-off sensors. These safeguards protect the engine and enhance the overall reliability of the device.

In summary, the Generac 004583-0 is a top-tier standby generator that combines power, efficiency, and advanced technology. With its robust engine, seamless automatic transfer capabilities, remote monitoring, and focus on safety and durability, it stands out as an excellent solution for homeowners seeking reliable backup power.