Generac 004583-0 Automatic Idle Control, LOW OIL Pressure Shutdown System, Stopping the Engine

Page 14

Section 2 – Operation

Residential Portable Generator System

• Move engine CHOKE knob to “Full Choke” position.

2.9 AUTOMATIC IDLE CONTROL

Figure 17 - Full Choke Position

To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.

When the engine starts, move choke knob to “1/2 Choke” position until the engine runs smoothly and then to “Run” position. If engine falters, move choke knob to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.

Note: If engine fires, but does not continue to run, move choke lever to “Full Choke” and repeat starting instructions.

This feature is designed to greatly improve fuel economy. When this switch is turned “On,” the engine will only run at its normal fast governed engine speed when electrical load is connected. When the load is removed, the engine will run at a reduced speed of 2100 RPM. With the switch “Off,” the engine runs at the normal fast engine speed all the time. Always have the switch OFF when starting and stopping the engine.

2.10 COLD WEATHER OPERATION/ DE-ICER

Under certain weather conditions (temperatures below 40° F (4°

C)and a high dew point), the engine may experience icing of the carburetor and/or the crankcase breather system. To eliminate this problem, this generator engine is fitted with a winter/summer valve. this directs hot air into the carburetor during cold weather operation. Always make sure the winter/summer valve is in the correct location relative to the weather conditions.

2.11LOW OIL PRESSURE SHUTDOWN SYSTEM

The engine is equipped with a low oil pressure sensor that shuts down the engine automatically when the oil pressure drops below 10 psi. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.

2.8 STOPPING THE ENGINE

Shut off all loads, then unplug the electrical loads from generator panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on.

Turn “Off” the Idle Control switch (if on).

Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator.

Move Start/Run/Stop switch to “Off” position.

Close fuel valve.

IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” on page 9 carefully.

2.11.1 INITIAL START-UP

A delay built into the low oil shutdown system allows oil pressure to build during starting. The delay allows the engine to run for about 10 seconds before sensing oil pressure.

2.11.2 SENSING LOW OIL PRESSURE

If the system senses low oil pressure during operation, the engine shuts down.

2.11.3 RESTARTING

If you try to restart the engine within 10 seconds after it shuts down, the engine may NOT start. The system needs 5 to 10 seconds to reset.

If you do restart the engine after such a shutdown and have not corrected the low oil pressure, the engine runs for about 10 seconds as described above and then stops.

12

Image 14
Contents Owner’s Manual Authorized Dealer SupportTable of Contents Residential Portable Generator System TroubleshootingRead this Manual Thoroughly General Hazards Never operate in an enclosed area or indoorsFire Hazards Electrical HazardsExplosion Hazards Assembling the Wheel KIT Accessory BOXUnpacking Assembling the HandleBattery Connection Handle AssemblyKnow the Generator 2 120V AC, 20 AMP, Gfci Receptacle Cord Sets and Connection Plugs1 AC, 20 AMP, Duplex Receptacle 5 12 Volt DC, 10 AMP Receptacle Provided. This receptacle can not recharge 6 Volt batteriesDON’T Overload the Generator HOW to USE the GeneratorConnecting Electrical Loads Grounding the GeneratorAdding Engine OIL Wattage Reference GuideBefore Starting the Generator To Start the Engine Adding GasolineStopping the Engine Automatic Idle ControlLOW OIL Pressure Shutdown System Charging a Battery To recharge 12 Volt batteries, proceed as followsMaintenance Schedule Maintenance Residential Portable Generator SystemTo Clean the Generator Generator MaintenanceEngine Maintenance Checking OIL Level General RecommendationsReplacing the Spark Plug Service AIR CleanerClean Spark Arrestor Screen Adjusting Valve Clearance To adjust valve clearanceOther Storage Tips GeneralLong Term Storage Troubleshooting Tools Required Installation for Manual Transfer SwitchKIT Includes Items YOU Must PurchaseThese Instructions are to Serve AS a Guide only Silicone Caulk7a Prepare Box For Connections Connection of Emergency Circuits Using the Ultra Source Portable Operation of Generator with Manual Transfer SwitchTransfer Back to Utility Power Source Transfer to Generator Power Source When Utility Power FailsInterconnection Drawing Residential Portable Generator System Engine Wiring Closest to Bearing Schematic, UltraSource Portable Generator Drawing No G0733 Wiring Diagram, Manual Transfer Switch Drawing No G1065 Manual Transfer Switch with Load Center Drawing No G0939-B Exploded Views and Parts Lists Description160 SystemQTY Description 118 116 119162 ListsQTY Description Part NO# Generator Drawing No D4488-F QTY Description Control Panel Drawing No G0727-B Part NO. QTY Description Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule

004583-0 specifications

Generac 004583-0 is a powerful and efficient home standby generator designed to provide reliable backup power during outages. This unit is specifically engineered to ensure that homeowners never have to worry about the disruption caused by power loss, keeping essential appliances and systems running smoothly, regardless of external conditions.

At the heart of the Generac 004583-0 is its robust engine, which delivers a peak output of 22 kW and is capable of running on either propane or natural gas. This fuel flexibility makes it an ideal choice for a variety of households, allowing users to select the fuel source that best fits their needs. The generator employs a high-performance, air-cooled engine featuring a durable construction that ensures long-lasting operation, and this reliability translates into peace of mind for homeowners.

One of the standout features of the Generac 004583-0 is its advanced Automatic Transfer Switch (ATS). The ATS seamlessly detects power outages and automatically switches the home’s electrical supply to the generator within seconds. This quick response is crucial for maintaining comfort and safety, especially during extreme weather conditions. The ATS also offers customizable settings, allowing homeowners to prioritize which circuits they want to power during an outage.

In addition to its seamless operation, the Generac 004583-0 integrates innovative technologies such as Mobile Link. This feature enables users to monitor the generator remotely via a smartphone app, providing real-time updates on the system’s status and maintenance needs. This connectivity enhances user experience and simplifies the management of the generator.

The generator is designed with a noise-reduction enclosure, ensuring that it operates quietly without disturbing daily life or neighborhood peace. Furthermore, the unit is built to withstand various weather conditions, featuring corrosion-resistant materials that ensure durability and a long service life.

Safety is paramount, and the Generac 004583-0 incorporates various safety features such as low oil and high-temperature shut-off sensors. These safeguards protect the engine and enhance the overall reliability of the device.

In summary, the Generac 004583-0 is a top-tier standby generator that combines power, efficiency, and advanced technology. With its robust engine, seamless automatic transfer capabilities, remote monitoring, and focus on safety and durability, it stands out as an excellent solution for homeowners seeking reliable backup power.