Section 5—Installation for Manual Transfer Switch

THESE INSTRUCTIONS ARE TO SERVE AS A GUIDE ONLY!

ANY ELECTRICAL WORK PERFORMED MUST MEET NFPA 70-NEC AND ANY LOCAL CODES THAT APPLY.

1

 

Portable Generator Placement

 

 

Generator should be placed as far away from

 

house as power cord will allow. It is understood

 

that the cord should not be pulled tight and it

 

will lay along the ground between the external

 

connection box and generator panel.

3

 

 

 

 

 

FIGURE A

2

 

1.PLAN THE LOCATION OF YOUR GENERATOR

(Fig. A) shows the GUARDIAN Ultra Source 17,5000 watt portable generator placed outside the home and connected to the weather protective external box. The ground rod and ground strap show a suggested location only. When fully installed the ground rod will not protrude above ground level. NOTE: Do not place the generator directly under a window.

Select an area outside of your home about 10 feet away where you can easily transport the portable generator to and from. Keep in mind that the generator must have free air flow for proper operation and to ensure there is no possibility for exhaust gases to build up.

2.Drive an 8-foot grounding rod into the ground to grade (so that no part is exposed above ground).

3 Drill Hole Through House

Drill Pass Through Hole

1-3/4”

Diameter Hole

With hole saw, drill hole through the sheathing and siding.

4.Measure the lengths of wire and conduit needed to reach the Manual Transfer Switch. Allow extra length to clear the joists/studs. While adhering to all local electrical codes, route the customer supplied conduit and wiring along ceiling/floor joists and wall studs to the location where the conduit will pass through the wall to the exterior of the house.

5 Feed Conduit and Wires

Silicone

Caulk

5.From the inside of the house, feed the end of the customer supplied conduit through the wall to outside.

6

 

Threaded Lock Nut

1-3/4”

Diameter Hole

3.Determine where the user supplied conduit will pass through the house from inside to outside. When you are certain you have clearance on each side of the wall, drill a small pilot hole through the wall to mark the location.

6.Remove the threaded lock nut from the conduit coupling.

21

Image 23
Contents Authorized Dealer Support Owner’s ManualTroubleshooting Table of Contents Residential Portable Generator SystemRead this Manual Thoroughly Never operate in an enclosed area or indoors General HazardsFire Hazards Electrical HazardsExplosion Hazards Assembling the Handle Accessory BOXUnpacking Assembling the Wheel KITHandle Assembly Battery ConnectionKnow the Generator 2 120V AC, 20 AMP, Gfci Receptacle Cord Sets and Connection Plugs1 AC, 20 AMP, Duplex Receptacle Provided. This receptacle can not recharge 6 Volt batteries 5 12 Volt DC, 10 AMP ReceptacleGrounding the Generator HOW to USE the GeneratorConnecting Electrical Loads DON’T Overload the GeneratorAdding Engine OIL Wattage Reference GuideBefore Starting the Generator Adding Gasoline To Start the EngineStopping the Engine Automatic Idle ControlLOW OIL Pressure Shutdown System To recharge 12 Volt batteries, proceed as follows Charging a BatteryMaintenance Residential Portable Generator System Maintenance ScheduleGeneral Recommendations Generator MaintenanceEngine Maintenance Checking OIL Level To Clean the GeneratorReplacing the Spark Plug Service AIR CleanerClean Spark Arrestor Screen To adjust valve clearance Adjusting Valve ClearanceOther Storage Tips GeneralLong Term Storage Troubleshooting Items YOU Must Purchase Installation for Manual Transfer SwitchKIT Includes Tools RequiredSilicone Caulk These Instructions are to Serve AS a Guide only7a Prepare Box For Connections Connection of Emergency Circuits Operation of Generator with Manual Transfer Switch Using the Ultra Source PortableTransfer to Generator Power Source When Utility Power Fails Transfer Back to Utility Power SourceInterconnection Drawing Residential Portable Generator System Engine Wiring Closest to Bearing Schematic, UltraSource Portable Generator Drawing No G0733 Wiring Diagram, Manual Transfer Switch Drawing No G1065 Manual Transfer Switch with Load Center Drawing No G0939-B Description Exploded Views and Parts ListsSystem 160QTY Description Lists 118 116 119162QTY Description Part NO# Generator Drawing No D4488-F QTY Description Control Panel Drawing No G0727-B Part NO. QTY Description Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule

004583-0 specifications

Generac 004583-0 is a powerful and efficient home standby generator designed to provide reliable backup power during outages. This unit is specifically engineered to ensure that homeowners never have to worry about the disruption caused by power loss, keeping essential appliances and systems running smoothly, regardless of external conditions.

At the heart of the Generac 004583-0 is its robust engine, which delivers a peak output of 22 kW and is capable of running on either propane or natural gas. This fuel flexibility makes it an ideal choice for a variety of households, allowing users to select the fuel source that best fits their needs. The generator employs a high-performance, air-cooled engine featuring a durable construction that ensures long-lasting operation, and this reliability translates into peace of mind for homeowners.

One of the standout features of the Generac 004583-0 is its advanced Automatic Transfer Switch (ATS). The ATS seamlessly detects power outages and automatically switches the home’s electrical supply to the generator within seconds. This quick response is crucial for maintaining comfort and safety, especially during extreme weather conditions. The ATS also offers customizable settings, allowing homeowners to prioritize which circuits they want to power during an outage.

In addition to its seamless operation, the Generac 004583-0 integrates innovative technologies such as Mobile Link. This feature enables users to monitor the generator remotely via a smartphone app, providing real-time updates on the system’s status and maintenance needs. This connectivity enhances user experience and simplifies the management of the generator.

The generator is designed with a noise-reduction enclosure, ensuring that it operates quietly without disturbing daily life or neighborhood peace. Furthermore, the unit is built to withstand various weather conditions, featuring corrosion-resistant materials that ensure durability and a long service life.

Safety is paramount, and the Generac 004583-0 incorporates various safety features such as low oil and high-temperature shut-off sensors. These safeguards protect the engine and enhance the overall reliability of the device.

In summary, the Generac 004583-0 is a top-tier standby generator that combines power, efficiency, and advanced technology. With its robust engine, seamless automatic transfer capabilities, remote monitoring, and focus on safety and durability, it stands out as an excellent solution for homeowners seeking reliable backup power.