Generac 004583-0 Table of Contents Residential Portable Generator System, Troubleshooting

Page 2

Table of Contents

Residential Portable Generator System

Safety Rules

1-3

Section 1 – General Information

4

1.1

Unpacking

4

 

1.1.1

Accessory Box

4

1.2

Assembly

4

 

1.2.1 Assembling the Wheel Kit

4

 

1.2.2

Assembling the Handle

5

 

1.2.3

Battery Connection

5

Section 2 – Operation

6

2.1

Know The Generator

6

2.2

Cord Sets and Connector Plugs

7

 

2.2.1

120V AC, 20 A, Duplex Receptacle

7

 

2.2.2

120V AC, 20 A, GFCI Receptacle

7

 

2.2.3

120V AC, 30 A Receptacle

7-8

 

2.2.4

120/240V AC, 30 A, Receptacle

8

 

2.2.5

12 VDC, 10 Amp Receptacle

8

 

2.2.6

120/240V AC, 50 A, Receptacle

8

2.3

How To Use The Generator

9

 

2.3.1

Grounding The Generator

9

 

2.3.2

Connecting Electric Loads

9

2.4

Don’t Overload The Generator

9

2.5

Wattage Reference Chart

10

2.6

Before Starting The Generator

10

 

2.6.1

Adding Engine Oil

10

 

2.6.2

Adding Gasoline

11

2.7

To Start The Engine

11

2.8

Stopping The Engine

12

2.9

Automatic Idle Control

12

2.10

Cold Weather Operation/De-Icer

12

2.11

Low Oil Pressure Shutdown

12

 

2.11.1

Initial Start-up

12

 

2.11.2

Sensing Low Oil Pressure

12

 

2.11.3

Restarting

12

2.12

Charging a Battery

13

Section 3 – Maintenance

14

3.1

Maintenance Schedule

14

3.2

Product Specifications

14

 

3.2.1

Generator Specifications

14

 

3.2.2

Engine Specifications

14

3.3

General Recommendations

15

 

3.3.1

General Maintenance

15

 

3.3.2 To Clean The Generator

15

 

3.3.3

Engine Maintenance

15

 

3.3.4

Checking Oil Level

15

 

3.3.5 Changing The Oil & Oil Filter

15

 

3.3.6 Replacing The Spark Plug

16

3.4

Service Air Cleaner

16

3.5

Clean Spark Arrestor Screen

16

3.6

Adjusting Valve Clearance

17

3.7

General

......................................................................

18

3.8

Long Term Storage

18

3.9

Other Storage Tips

18

Section 4 – Troubleshooting

19

4.1 Troubleshooting Guide

19

Section 5 – Installation Guide For

 

 

Manual Transfer Switch

20-23

Section 6

– Operation Of Generator With

 

 

Manual Transfer Switch

24-26

Section 7

– Notes

27

Section 9

– Electrical Data

28-31

Section 9

– Exploded Views and

 

 

Parts Lists

32-43

Section 10 – Warranty

44-46

Image 2
Contents Owner’s Manual Authorized Dealer SupportTable of Contents Residential Portable Generator System TroubleshootingRead this Manual Thoroughly General Hazards Never operate in an enclosed area or indoorsFire Hazards Electrical HazardsExplosion Hazards Assembling the Wheel KIT Accessory BOXUnpacking Assembling the HandleBattery Connection Handle AssemblyKnow the Generator 2 120V AC, 20 AMP, Gfci Receptacle Cord Sets and Connection Plugs1 AC, 20 AMP, Duplex Receptacle 5 12 Volt DC, 10 AMP Receptacle Provided. This receptacle can not recharge 6 Volt batteriesDON’T Overload the Generator HOW to USE the GeneratorConnecting Electrical Loads Grounding the GeneratorAdding Engine OIL Wattage Reference GuideBefore Starting the Generator To Start the Engine Adding GasolineStopping the Engine Automatic Idle ControlLOW OIL Pressure Shutdown System Charging a Battery To recharge 12 Volt batteries, proceed as followsMaintenance Schedule Maintenance Residential Portable Generator SystemTo Clean the Generator Generator MaintenanceEngine Maintenance Checking OIL Level General RecommendationsReplacing the Spark Plug Service AIR CleanerClean Spark Arrestor Screen Adjusting Valve Clearance To adjust valve clearanceOther Storage Tips GeneralLong Term Storage Troubleshooting Tools Required Installation for Manual Transfer SwitchKIT Includes Items YOU Must PurchaseThese Instructions are to Serve AS a Guide only Silicone Caulk7a Prepare Box For Connections Connection of Emergency Circuits Using the Ultra Source Portable Operation of Generator with Manual Transfer SwitchTransfer Back to Utility Power Source Transfer to Generator Power Source When Utility Power FailsInterconnection Drawing Residential Portable Generator System Engine Wiring Closest to Bearing Schematic, UltraSource Portable Generator Drawing No G0733 Wiring Diagram, Manual Transfer Switch Drawing No G1065 Manual Transfer Switch with Load Center Drawing No G0939-B Exploded Views and Parts Lists Description160 SystemQTY Description 118 116 119162 ListsQTY Description Part NO# Generator Drawing No D4488-F QTY Description Control Panel Drawing No G0727-B Part NO. QTY Description Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule

004583-0 specifications

Generac 004583-0 is a powerful and efficient home standby generator designed to provide reliable backup power during outages. This unit is specifically engineered to ensure that homeowners never have to worry about the disruption caused by power loss, keeping essential appliances and systems running smoothly, regardless of external conditions.

At the heart of the Generac 004583-0 is its robust engine, which delivers a peak output of 22 kW and is capable of running on either propane or natural gas. This fuel flexibility makes it an ideal choice for a variety of households, allowing users to select the fuel source that best fits their needs. The generator employs a high-performance, air-cooled engine featuring a durable construction that ensures long-lasting operation, and this reliability translates into peace of mind for homeowners.

One of the standout features of the Generac 004583-0 is its advanced Automatic Transfer Switch (ATS). The ATS seamlessly detects power outages and automatically switches the home’s electrical supply to the generator within seconds. This quick response is crucial for maintaining comfort and safety, especially during extreme weather conditions. The ATS also offers customizable settings, allowing homeowners to prioritize which circuits they want to power during an outage.

In addition to its seamless operation, the Generac 004583-0 integrates innovative technologies such as Mobile Link. This feature enables users to monitor the generator remotely via a smartphone app, providing real-time updates on the system’s status and maintenance needs. This connectivity enhances user experience and simplifies the management of the generator.

The generator is designed with a noise-reduction enclosure, ensuring that it operates quietly without disturbing daily life or neighborhood peace. Furthermore, the unit is built to withstand various weather conditions, featuring corrosion-resistant materials that ensure durability and a long service life.

Safety is paramount, and the Generac 004583-0 incorporates various safety features such as low oil and high-temperature shut-off sensors. These safeguards protect the engine and enhance the overall reliability of the device.

In summary, the Generac 004583-0 is a top-tier standby generator that combines power, efficiency, and advanced technology. With its robust engine, seamless automatic transfer capabilities, remote monitoring, and focus on safety and durability, it stands out as an excellent solution for homeowners seeking reliable backup power.