Generac 004583-0 owner manual Read this Manual Thoroughly

Page 3

INTRODUCTION

Thank you for purchasing this model of the GUARDIAN® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads when utility power is unavailable due to a power outage.

READ THIS MANUAL THOROUGHLY

If you do not understand any portion of this manual, contact your nearest GENERAC/GUARDIAN® Authorized Dealer for starting, operating and servicing procedures.

Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert you to special instruction about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:

------------- DANGER -------------

After this heading, you can read instructions that, if not strictly complied with, will result in serious personal injury, severe property damage and/or including without limitation, death.

------------- WARNING -------------

After this heading, you can read instructions that, if not strictly complied with, may result in serious personal injury and/or property damage.

------------- CAUTION -------------

After this heading, you can read instructions that, if not strictly complied with, could result in damage to equipment and/or property.

NOTE: After this heading, you can read explanatory statements that require special emphasis. These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents.

Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates follows:

This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of you and others.

This symbol points out potential explosion hazard.

This symbol points out potential fire hazard.

This symbol points out potential electrical shock hazard.

The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this “Owner’s Manual” and thoroughly understand all instructions before using this equipment.

We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.

CAUTION! Always disconnect spark plug wire and place the wire where it cannot contact the spark plug to prevent accidental starting when setting up, transporting, adjusting or making repairs to your generator.

The generator produces dangerously high voltage that can cause extremely hazardous electrical shock. Avoid contact with bare wires, terminals, etc. Never permit any unqualified person to operate or service the generator.

Never handle any kind of electrical cord or device while standing in water, while barefoot or while hands or feet are wet. Dangerous electrical shock will result.

The National Electric Code requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the generator. Consult with a local electrician for grounding requirements in your area.

Use a ground fault circuit interrupter in any damp or highly conductive area (such as metal decking or steel work).

Do not use worn, bare, frayed or otherwise damaged electrical cord sets with the generator.

Operate generator only on level surfaces and where it will not be exposed to excessive moisture, dirt, dust or corrosive vapors.

Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. Comply with all laws regulating storage and handling of gasoline.

Never add fuel while unit is running.

Do not overfill the fuel tank. Always allow room for fuel expansion. If tank is over-filled, fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION.

Never store generator with fuel in tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater or clothes dryer). FIRE or EXPLOSION may result.

Generator exhaust gases contain DEADLY carbon monoxide gas.This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Operate this equipment only in the open air where adequate ventilation is available.

Allow at least 2 feet of clearance on all sides of generator or you could damage the unit. Never operate the unit inside any room or enclosure where the free flow of cooling air into and out of the unit might be obstructed. Review “Cold Weather Operation” on page 12.

------------- DANGER -------------

NEVER operate your generator indoors, in an attached garage or near an open window.

1

Image 3
Contents Authorized Dealer Support Owner’s ManualTroubleshooting Table of Contents Residential Portable Generator SystemRead this Manual Thoroughly Never operate in an enclosed area or indoors General HazardsElectrical Hazards Explosion HazardsFire Hazards Assembling the Handle Accessory BOXUnpacking Assembling the Wheel KITHandle Assembly Battery ConnectionKnow the Generator Cord Sets and Connection Plugs 1 AC, 20 AMP, Duplex Receptacle2 120V AC, 20 AMP, Gfci Receptacle Provided. This receptacle can not recharge 6 Volt batteries 5 12 Volt DC, 10 AMP ReceptacleGrounding the Generator HOW to USE the GeneratorConnecting Electrical Loads DON’T Overload the GeneratorWattage Reference Guide Before Starting the GeneratorAdding Engine OIL Adding Gasoline To Start the EngineAutomatic Idle Control LOW OIL Pressure Shutdown SystemStopping the Engine To recharge 12 Volt batteries, proceed as follows Charging a BatteryMaintenance Residential Portable Generator System Maintenance ScheduleGeneral Recommendations Generator MaintenanceEngine Maintenance Checking OIL Level To Clean the GeneratorService AIR Cleaner Clean Spark Arrestor ScreenReplacing the Spark Plug To adjust valve clearance Adjusting Valve ClearanceGeneral Long Term StorageOther Storage Tips Troubleshooting Items YOU Must Purchase Installation for Manual Transfer SwitchKIT Includes Tools RequiredSilicone Caulk These Instructions are to Serve AS a Guide only7a Prepare Box For Connections Connection of Emergency Circuits Operation of Generator with Manual Transfer Switch Using the Ultra Source PortableTransfer to Generator Power Source When Utility Power Fails Transfer Back to Utility Power SourceInterconnection Drawing Residential Portable Generator System Engine Wiring Closest to Bearing Schematic, UltraSource Portable Generator Drawing No G0733 Wiring Diagram, Manual Transfer Switch Drawing No G1065 Manual Transfer Switch with Load Center Drawing No G0939-B Description Exploded Views and Parts ListsSystem 160QTY Description Lists 118 116 119162QTY Description Part NO# Generator Drawing No D4488-F QTY Description Control Panel Drawing No G0727-B Part NO. QTY Description Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Warranty Schedule

004583-0 specifications

Generac 004583-0 is a powerful and efficient home standby generator designed to provide reliable backup power during outages. This unit is specifically engineered to ensure that homeowners never have to worry about the disruption caused by power loss, keeping essential appliances and systems running smoothly, regardless of external conditions.

At the heart of the Generac 004583-0 is its robust engine, which delivers a peak output of 22 kW and is capable of running on either propane or natural gas. This fuel flexibility makes it an ideal choice for a variety of households, allowing users to select the fuel source that best fits their needs. The generator employs a high-performance, air-cooled engine featuring a durable construction that ensures long-lasting operation, and this reliability translates into peace of mind for homeowners.

One of the standout features of the Generac 004583-0 is its advanced Automatic Transfer Switch (ATS). The ATS seamlessly detects power outages and automatically switches the home’s electrical supply to the generator within seconds. This quick response is crucial for maintaining comfort and safety, especially during extreme weather conditions. The ATS also offers customizable settings, allowing homeowners to prioritize which circuits they want to power during an outage.

In addition to its seamless operation, the Generac 004583-0 integrates innovative technologies such as Mobile Link. This feature enables users to monitor the generator remotely via a smartphone app, providing real-time updates on the system’s status and maintenance needs. This connectivity enhances user experience and simplifies the management of the generator.

The generator is designed with a noise-reduction enclosure, ensuring that it operates quietly without disturbing daily life or neighborhood peace. Furthermore, the unit is built to withstand various weather conditions, featuring corrosion-resistant materials that ensure durability and a long service life.

Safety is paramount, and the Generac 004583-0 incorporates various safety features such as low oil and high-temperature shut-off sensors. These safeguards protect the engine and enhance the overall reliability of the device.

In summary, the Generac 004583-0 is a top-tier standby generator that combines power, efficiency, and advanced technology. With its robust engine, seamless automatic transfer capabilities, remote monitoring, and focus on safety and durability, it stands out as an excellent solution for homeowners seeking reliable backup power.