Briggs & Stratton 13500 manual Maintenance Schedule, Generator Maintenance

Page 18

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

Maintenance Schedule - Fill in Dates as You Complete Regular Service

Maintenance Task

 

 

 

 

Service Intervals

 

Service Dates

 

Before

 

Every 25 Hours

 

Every 50 Hours

 

Every 100

 

Every 250

 

 

 

 

 

 

 

 

 

 

 

 

Each Use

 

or Yearly

 

or Yearly

 

Hours or Yearly

 

Hours or Yearly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean debris

X

 

 

 

 

 

 

 

 

 

 

 

Check oil level

X

 

 

 

 

 

 

 

 

 

 

 

Change engine oil

 

 

 

 

X1

 

 

 

 

 

 

 

Service air cleaner

 

 

X2

 

 

 

 

 

 

 

 

 

pre-filter

 

 

 

 

 

 

 

 

 

 

 

 

Service air cleaner

 

 

 

 

 

 

X2

 

 

 

 

 

paper filter

 

 

 

 

 

 

 

 

 

 

 

 

Service spark plug

 

 

 

 

 

 

X

 

 

 

 

 

Service spark arrester

 

 

 

 

 

 

X

 

 

 

 

 

Clean cooling system

 

 

 

 

 

 

X2

 

 

 

 

 

Check valve clearance

 

 

 

 

 

 

 

 

X

 

 

 

Prepare for storage

 

 

If unit is to

 

remain idle for longer than 30 days.

 

 

 

 

1Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter. Change oil sooner when operating under dirty or dusty conditions.

2Replace more often under dirty or dusty conditions.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See an authorized dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

18

BRIGGSandSTRATTON.COM

Image 18
Contents Operator’s Manual Engine Where to Find UsGenerator Date PurchasedTable of Contents Safety alert symbol is used with a signal word Operator SafetySafety Rules Hazard Symbols and MeaningsEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultContact with muffler area can result in serious burns Unintentional sparking can result in fire or electric shockInstall the wheel kit as follows AssemblyInstall Wheel Kit Unpack GeneratorReplace oil fill cap and fully tighten Add Engine OilAdd Fuel Fuel must meet these requirementsTo install Attach Negative Battery CableConnecting to a Building’s Electrical System System GroundGenerator Location Clearances and Air MovementVolt AC, 20 Amp, Duplex Receptacles May be Features and ControlsUsed to supply electrical power for the operation Items Not Shown120/240 Volt AC, 30 Amp, Locking Receptacle Cord Sets and ReceptaclesNema L14-30 Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Operation Starting the EngineStopping the Engine Connecting Electrical LoadsOil Pressure Shutdown Cold Weather OperationCreating a Temporary Shelter An emergency, use the original shipping cartonCreating a Permanent Shelter Don’t Overload Generator Wattage Reference GuideMaintenance Maintenance ScheduleGenerator Maintenance Battery Maintenance Engine MaintenanceOil Wipe clean inside of base E and cover thoroughly Service Air CleanerTo service the air cleaner, follow these steps Service Spark PlugCarburetor Adjustment Install spark plug and tighten firmlyService Spark Arrester Air Cooling SystemStorage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty Page Product Specifications Common Service Parts800

13500 specifications

The Briggs & Stratton 13500 is a powerful generator designed to provide reliable mobile power for various applications. Known for its robust construction and innovative features, this generator is an excellent choice for both home use and outdoor activities such as camping or tailgating.

One of the standout features of the Briggs & Stratton 13500 is its 13,500 starting watts and 10,000 running watts capability. This impressive output makes it suitable for powering heavy-duty appliances, tools, and other electrical devices during power outages or when engaging in outdoor recreational activities. The generator’s ability to handle large loads provides peace of mind, especially in emergency situations.

This generator is equipped with a high-performance OHV engine that ensures durability and reliable operation. The engine features a cast iron sleeve that enhances longevity and reduces wear over time. Additionally, it has a low-oil shutdown system that automatically engages when the oil level is too low, protecting the engine from damage and prolonging its life.

The Briggs & Stratton 13500 also showcases a user-friendly control panel. This panel includes multiple outlets, such as heavy-duty 120V and 120/240V outlets, allowing users to connect various devices simultaneously. The presence of an easy-to-read Voltmeter and Circuit Breaker protection ensures safety and efficiency when connecting loads.

Another important aspect is the generator’s portability. It features durable wheels and a foldable handle, making transportation easy. Whether you need to relocate it around your property or take it on the go, the Briggs & Stratton 13500 is designed with user convenience in mind.

The generator operates quietly for its size, making it an excellent option for residential neighborhoods where noise pollution can be a concern. Additionally, it is built to be fuel-efficient, meaning users can run the generator for extended periods without frequent refueling.

Safety is a priority with the Briggs & Stratton 13500 as well. It includes features like a surge protector and advanced cooling systems which prevent overheating. This ensures that users can operate the generator confidently without worrying about unexpected failures.

In summary, the Briggs & Stratton 13500 generator stands out with its powerful performance, durable construction, portable design, user-friendly features, and safety mechanisms. Whether for emergency backup power or outdoor activities, this generator provides a reliable solution for a wide range of power needs.