Briggs & Stratton 13500 manual Attach Negative Battery Cable, System Ground, To install

Page 9

Attach Negative Battery Cable

Your unit is equipped with electric start capability but can be started manually. If you choose not to use the electric start feature, you do not need to connect the negative battery cable.

The sealed battery on the generator pre–installed except for the negative (black) battery cable.

To install:

1.Cut off tie wrap securing loose end of negative (black) cable.

2.Remove screw (A), lock washer (B) and flat washer (C) on negative battery terminal.

D

A

C

B

3.Slide lock washer, flat washer and negative battery cable (D) over screw.

4.Reattach screw to negative battery terminal and tighten.

5.Verify that connections to battery and generator are tight and secure.

NOTE: If your battery is discharged, charge prior to use following the instructions in the section Battery Float Charger.

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power or other alternative power sources and must comply with all applicable laws and electrical codes.

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

9

Image 9
Contents Operator’s Manual Generator Where to Find UsEngine Date PurchasedTable of Contents Safety Rules Operator SafetySafety alert symbol is used with a signal word Hazard Symbols and MeaningsBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsUnintentional sparking can result in fire or electric shock Contact with muffler area can result in serious burnsInstall Wheel Kit AssemblyInstall the wheel kit as follows Unpack GeneratorAdd Fuel Add Engine OilReplace oil fill cap and fully tighten Fuel must meet these requirementsConnecting to a Building’s Electrical System Attach Negative Battery CableTo install System GroundClearances and Air Movement Generator LocationUsed to supply electrical power for the operation Features and ControlsVolt AC, 20 Amp, Duplex Receptacles May be Items Not ShownNema L14-30 Cord Sets and Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Starting the Engine OperationOil Pressure Shutdown Connecting Electrical LoadsStopping the Engine Cold Weather OperationCreating a Temporary Shelter An emergency, use the original shipping cartonCreating a Permanent Shelter Wattage Reference Guide Don’t Overload GeneratorMaintenance Maintenance ScheduleGenerator Maintenance Battery Maintenance Engine MaintenanceOil To service the air cleaner, follow these steps Service Air CleanerWipe clean inside of base E and cover thoroughly Service Spark PlugService Spark Arrester Install spark plug and tighten firmlyCarburetor Adjustment Air Cooling SystemStorage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty Page Product Specifications Common Service Parts800

13500 specifications

The Briggs & Stratton 13500 is a powerful generator designed to provide reliable mobile power for various applications. Known for its robust construction and innovative features, this generator is an excellent choice for both home use and outdoor activities such as camping or tailgating.

One of the standout features of the Briggs & Stratton 13500 is its 13,500 starting watts and 10,000 running watts capability. This impressive output makes it suitable for powering heavy-duty appliances, tools, and other electrical devices during power outages or when engaging in outdoor recreational activities. The generator’s ability to handle large loads provides peace of mind, especially in emergency situations.

This generator is equipped with a high-performance OHV engine that ensures durability and reliable operation. The engine features a cast iron sleeve that enhances longevity and reduces wear over time. Additionally, it has a low-oil shutdown system that automatically engages when the oil level is too low, protecting the engine from damage and prolonging its life.

The Briggs & Stratton 13500 also showcases a user-friendly control panel. This panel includes multiple outlets, such as heavy-duty 120V and 120/240V outlets, allowing users to connect various devices simultaneously. The presence of an easy-to-read Voltmeter and Circuit Breaker protection ensures safety and efficiency when connecting loads.

Another important aspect is the generator’s portability. It features durable wheels and a foldable handle, making transportation easy. Whether you need to relocate it around your property or take it on the go, the Briggs & Stratton 13500 is designed with user convenience in mind.

The generator operates quietly for its size, making it an excellent option for residential neighborhoods where noise pollution can be a concern. Additionally, it is built to be fuel-efficient, meaning users can run the generator for extended periods without frequent refueling.

Safety is a priority with the Briggs & Stratton 13500 as well. It includes features like a surge protector and advanced cooling systems which prevent overheating. This ensures that users can operate the generator confidently without worrying about unexpected failures.

In summary, the Briggs & Stratton 13500 generator stands out with its powerful performance, durable construction, portable design, user-friendly features, and safety mechanisms. Whether for emergency backup power or outdoor activities, this generator provides a reliable solution for a wide range of power needs.