Briggs & Stratton 13500 manual Contact with muffler area can result in serious burns

Page 6

WARNING

Contact with muffler area can result in serious burns.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot parts and AVOID hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Starter and other rotating parts can entangle hands, hair, clothing, or accessories.

NEVER operate generator without protective housing or covers.

DO NOT wear loose clothing, jewelry or anything that may be caught in the starter or other rotating parts.

Tie up long hair and remove jewelry.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

DO NOT exceed the generator’s wattage/amperage capacity. See Don’t Overload Generator in the Operation section.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact local service center.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

6

BRIGGSandSTRATTON.COM

Image 6
Contents Operator’s Manual Engine Where to Find UsGenerator Date PurchasedTable of Contents Safety alert symbol is used with a signal word Operator SafetySafety Rules Hazard Symbols and MeaningsEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultContact with muffler area can result in serious burns Unintentional sparking can result in fire or electric shockInstall the wheel kit as follows AssemblyInstall Wheel Kit Unpack GeneratorReplace oil fill cap and fully tighten Add Engine OilAdd Fuel Fuel must meet these requirementsTo install Attach Negative Battery CableConnecting to a Building’s Electrical System System GroundGenerator Location Clearances and Air MovementVolt AC, 20 Amp, Duplex Receptacles May be Features and ControlsUsed to supply electrical power for the operation Items Not Shown120/240 Volt AC, 30 Amp, Locking Receptacle Cord Sets and ReceptaclesNema L14-30 Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Operation Starting the EngineStopping the Engine Connecting Electrical LoadsOil Pressure Shutdown Cold Weather OperationCreating a Temporary Shelter An emergency, use the original shipping cartonCreating a Permanent Shelter Don’t Overload Generator Wattage Reference GuideMaintenance Maintenance ScheduleGenerator Maintenance Battery Maintenance Engine MaintenanceOil Wipe clean inside of base E and cover thoroughly Service Air CleanerTo service the air cleaner, follow these steps Service Spark PlugCarburetor Adjustment Install spark plug and tighten firmlyService Spark Arrester Air Cooling SystemStorage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty Page Product Specifications Common Service Parts800

13500 specifications

The Briggs & Stratton 13500 is a powerful generator designed to provide reliable mobile power for various applications. Known for its robust construction and innovative features, this generator is an excellent choice for both home use and outdoor activities such as camping or tailgating.

One of the standout features of the Briggs & Stratton 13500 is its 13,500 starting watts and 10,000 running watts capability. This impressive output makes it suitable for powering heavy-duty appliances, tools, and other electrical devices during power outages or when engaging in outdoor recreational activities. The generator’s ability to handle large loads provides peace of mind, especially in emergency situations.

This generator is equipped with a high-performance OHV engine that ensures durability and reliable operation. The engine features a cast iron sleeve that enhances longevity and reduces wear over time. Additionally, it has a low-oil shutdown system that automatically engages when the oil level is too low, protecting the engine from damage and prolonging its life.

The Briggs & Stratton 13500 also showcases a user-friendly control panel. This panel includes multiple outlets, such as heavy-duty 120V and 120/240V outlets, allowing users to connect various devices simultaneously. The presence of an easy-to-read Voltmeter and Circuit Breaker protection ensures safety and efficiency when connecting loads.

Another important aspect is the generator’s portability. It features durable wheels and a foldable handle, making transportation easy. Whether you need to relocate it around your property or take it on the go, the Briggs & Stratton 13500 is designed with user convenience in mind.

The generator operates quietly for its size, making it an excellent option for residential neighborhoods where noise pollution can be a concern. Additionally, it is built to be fuel-efficient, meaning users can run the generator for extended periods without frequent refueling.

Safety is a priority with the Briggs & Stratton 13500 as well. It includes features like a surge protector and advanced cooling systems which prevent overheating. This ensures that users can operate the generator confidently without worrying about unexpected failures.

In summary, the Briggs & Stratton 13500 generator stands out with its powerful performance, durable construction, portable design, user-friendly features, and safety mechanisms. Whether for emergency backup power or outdoor activities, this generator provides a reliable solution for a wide range of power needs.