Briggs & Stratton 13500 manual Engine exhaust from this product contains

Page 5

WARNING

The engine exhaust from this product contains

chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises, or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap, and air cleaner are in place.

DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

5

Image 5
Contents Operator’s Manual Generator Where to Find UsEngine Date PurchasedTable of Contents Safety Rules Operator SafetySafety alert symbol is used with a signal word Hazard Symbols and MeaningsBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsUnintentional sparking can result in fire or electric shock Contact with muffler area can result in serious burnsInstall Wheel Kit AssemblyInstall the wheel kit as follows Unpack GeneratorAdd Fuel Add Engine OilReplace oil fill cap and fully tighten Fuel must meet these requirementsConnecting to a Building’s Electrical System Attach Negative Battery CableTo install System GroundClearances and Air Movement Generator LocationUsed to supply electrical power for the operation Features and ControlsVolt AC, 20 Amp, Duplex Receptacles May be Items Not ShownNema L14-30 Cord Sets and Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Starting the Engine OperationOil Pressure Shutdown Connecting Electrical LoadsStopping the Engine Cold Weather OperationCreating a Permanent Shelter Creating a Temporary ShelterAn emergency, use the original shipping carton Wattage Reference Guide Don’t Overload GeneratorGenerator Maintenance MaintenanceMaintenance Schedule Oil Battery MaintenanceEngine Maintenance To service the air cleaner, follow these steps Service Air CleanerWipe clean inside of base E and cover thoroughly Service Spark PlugService Spark Arrester Install spark plug and tighten firmlyCarburetor Adjustment Air Cooling SystemStorage Troubleshooting Warranties Emissions Control System WarrantyOwner’s Warranty Responsibilities Claims and Coverage Exclusions MaintenanceEmission Information Limited Warranty Page 800 Product SpecificationsCommon Service Parts

13500 specifications

The Briggs & Stratton 13500 is a powerful generator designed to provide reliable mobile power for various applications. Known for its robust construction and innovative features, this generator is an excellent choice for both home use and outdoor activities such as camping or tailgating.

One of the standout features of the Briggs & Stratton 13500 is its 13,500 starting watts and 10,000 running watts capability. This impressive output makes it suitable for powering heavy-duty appliances, tools, and other electrical devices during power outages or when engaging in outdoor recreational activities. The generator’s ability to handle large loads provides peace of mind, especially in emergency situations.

This generator is equipped with a high-performance OHV engine that ensures durability and reliable operation. The engine features a cast iron sleeve that enhances longevity and reduces wear over time. Additionally, it has a low-oil shutdown system that automatically engages when the oil level is too low, protecting the engine from damage and prolonging its life.

The Briggs & Stratton 13500 also showcases a user-friendly control panel. This panel includes multiple outlets, such as heavy-duty 120V and 120/240V outlets, allowing users to connect various devices simultaneously. The presence of an easy-to-read Voltmeter and Circuit Breaker protection ensures safety and efficiency when connecting loads.

Another important aspect is the generator’s portability. It features durable wheels and a foldable handle, making transportation easy. Whether you need to relocate it around your property or take it on the go, the Briggs & Stratton 13500 is designed with user convenience in mind.

The generator operates quietly for its size, making it an excellent option for residential neighborhoods where noise pollution can be a concern. Additionally, it is built to be fuel-efficient, meaning users can run the generator for extended periods without frequent refueling.

Safety is a priority with the Briggs & Stratton 13500 as well. It includes features like a surge protector and advanced cooling systems which prevent overheating. This ensures that users can operate the generator confidently without worrying about unexpected failures.

In summary, the Briggs & Stratton 13500 generator stands out with its powerful performance, durable construction, portable design, user-friendly features, and safety mechanisms. Whether for emergency backup power or outdoor activities, this generator provides a reliable solution for a wide range of power needs.