Briggs & Stratton 13500 manual Battery Maintenance, Engine Maintenance, Oil

Page 19

NOTICE

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

Engine Maintenance

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Oil

Oil Recommendations

We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.

Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.

* Below 40°F (4°C) the use of SAE 30 will result in hard starting.

**Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.

NOTE: Synthetic oil meeting ILSAC GF-2, API

certification mark and API service symbol with

“SJ/CF ENERGY CONSERVING” or higher, is an

acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.

Checking Oil Level

Oil level should be checked prior to each use or at least every 5 hours of operation. Keep oil level maintained.

1.Make sure generator is on a level surface.

2.Clean area around oil fill, remove oil cap/dipstick and wipe dipstick with clean cloth. Replace and tighten dipstick. Remove and and check oil level.

3.Verify oil is at “Full” mark (A) on dipstick. Replace and tighten oil cap/dipstick.

A

Adding Engine Oil

1.Make sure generator is on a level surface.

2.Check oil level as described in Checking Oil Level.

3.If needed, slowly pour oil into oil fill opening to the “Full” mark on dipstick. DO NOT overfill.

NOTICE

Overfilling with oil may cause the engine to not start, or hard starting.

DO NOT overfill.

If over the FULL mark on dipstick, drain oil to reduce oil level to FULL mark on dipstick.

4.Replace and tighten oil cap/dipstick.

19

Image 19
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsUnintentional sparking can result in fire or electric shock Contact with muffler area can result in serious burnsUnpack Generator AssemblyInstall Wheel Kit Install the wheel kit as followsFuel must meet these requirements Add Engine OilAdd Fuel Replace oil fill cap and fully tightenSystem Ground Attach Negative Battery CableConnecting to a Building’s Electrical System To installClearances and Air Movement Generator LocationItems Not Shown Features and ControlsUsed to supply electrical power for the operation Volt AC, 20 Amp, Duplex Receptacles May beVolt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleBattery Float Charger Starting the Engine OperationCold Weather Operation Connecting Electrical LoadsOil Pressure Shutdown Stopping the EngineAn emergency, use the original shipping carton Creating a Temporary ShelterCreating a Permanent Shelter Wattage Reference Guide Don’t Overload GeneratorMaintenance Schedule MaintenanceGenerator Maintenance Engine Maintenance Battery MaintenanceOil Service Spark Plug Service Air CleanerTo service the air cleaner, follow these steps Wipe clean inside of base E and cover thoroughlyAir Cooling System Install spark plug and tighten firmlyService Spark Arrester Carburetor AdjustmentStorage Troubleshooting Owner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty Page Common Service Parts Product Specifications800

13500 specifications

The Briggs & Stratton 13500 is a powerful generator designed to provide reliable mobile power for various applications. Known for its robust construction and innovative features, this generator is an excellent choice for both home use and outdoor activities such as camping or tailgating.

One of the standout features of the Briggs & Stratton 13500 is its 13,500 starting watts and 10,000 running watts capability. This impressive output makes it suitable for powering heavy-duty appliances, tools, and other electrical devices during power outages or when engaging in outdoor recreational activities. The generator’s ability to handle large loads provides peace of mind, especially in emergency situations.

This generator is equipped with a high-performance OHV engine that ensures durability and reliable operation. The engine features a cast iron sleeve that enhances longevity and reduces wear over time. Additionally, it has a low-oil shutdown system that automatically engages when the oil level is too low, protecting the engine from damage and prolonging its life.

The Briggs & Stratton 13500 also showcases a user-friendly control panel. This panel includes multiple outlets, such as heavy-duty 120V and 120/240V outlets, allowing users to connect various devices simultaneously. The presence of an easy-to-read Voltmeter and Circuit Breaker protection ensures safety and efficiency when connecting loads.

Another important aspect is the generator’s portability. It features durable wheels and a foldable handle, making transportation easy. Whether you need to relocate it around your property or take it on the go, the Briggs & Stratton 13500 is designed with user convenience in mind.

The generator operates quietly for its size, making it an excellent option for residential neighborhoods where noise pollution can be a concern. Additionally, it is built to be fuel-efficient, meaning users can run the generator for extended periods without frequent refueling.

Safety is a priority with the Briggs & Stratton 13500 as well. It includes features like a surge protector and advanced cooling systems which prevent overheating. This ensures that users can operate the generator confidently without worrying about unexpected failures.

In summary, the Briggs & Stratton 13500 generator stands out with its powerful performance, durable construction, portable design, user-friendly features, and safety mechanisms. Whether for emergency backup power or outdoor activities, this generator provides a reliable solution for a wide range of power needs.