MAINTENANCE
6.Clean paper filter by tapping it gently on a solid surface. If the paper filter is too dirty, replace it with a new one. Dispose of the old filter properly.
6.Insert the foam
8.Reinstall air cleaner cover and tighten screws.
Clean/Replace Spark Plug
Check and clean the spark plug every 100 hours of operation or yearly, whichever comes first.This will help your engine to start easier and run better.
1.Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
2.Clean the area around the spark plug.
3.Remove and inspect the spark plug.
4.Replace the spark plug if electrodes are pitted or burned or the porcelain is cracked. Use a Champion RC14YC or equivalent plug for replacement.
5.Check electrode gap with wire feeler gauge and set spark plug gap to 0.030 inch (0.76 mm) if necessary (Figure 17).
WARNING
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.
•DO NOT touch hot surfaces and avoid hot exhaust gases.
•Allow equipment to cool before touching.
•Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.
•Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard
Clean and inspect the spark arrester as follows:
1.To remove muffler heat shield from muffler, remove four screws that connect guard to muffler bracket (Figure 18).
Figure 17 — Service Spark Plug
6.Reinstall spark plug.
7.Reconnect spark plug wire to spark plug.
Clean Spark Arrester Screen
The engine exhaust muffler has a spark arrester screen. Inspect and clean the screen every 100 hours of operation or once each year, whichever comes first.
If you use your generator on any
Figure 18 — Service Spark Arrester
2. | Remove four screws that attach spark arrester screen. |
3.Inspect screen and replace if torn, perforated or otherwise damaged. DO NOT use a defective screen. If screen is not damaged, clean it with commercial solvent.
4.Reattach screen and muffler guard.
19