Briggs & Stratton 30244 manual Warranty is not Transferable

Page 28

Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983

GENERAC POWER SYSTEMS’ TWO-YEAR LIMITED WARRANTY FOR GSH SERIES ENGINES

For a period of (2) two years of operation from the date of original sale, Generac Power Systems, Inc. (Generac) will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Facility, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Facility. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner.This warranty applies only to Generac GSH engines sold and rated for GSH engine applications, as Generac has defined GSH engine applications.This warranty pertains only to the GSH engines utilized to power equipment. Examples include, but are not limited to, portable generators, pressure washers, air compressors, welders, lawn tractors and mowers, snow blowers, edgers and pumps.This warranty does not cover engines used in competitive events. THIS

WARRANTY IS NOT TRANSFERABLE.

WARRANTY SCHEDULE

GSH engines bound for export outside of North America shall be warranted for a period of 1 (one) year for consumer/commercial/industrial applications.

CONSUMER/COMMERCIAL/INDUSTRIAL APPLICATIONS

YEAR ONE and TWO – 100% (one hundred percent) coverage on part(s) and labor as listed (proof of purchase required):

Engine – All components

All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedure and Flat Rate Manual for Engines.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

Generac engines that utilize non-Generac replacement parts.

Costs of normal maintenance, adjustments, installation and start-up.

Failures caused by any contaminated fuels, oils, or lack of proper fluid amounts.

Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, use in competitive events, negligence or improper installation. As with all mechanical devices, the GSH Series engines need periodic part(s) service and replacement to perform well.This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine.

Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.

Products that are modified or altered in a manner not authorized by Generac in writing.

Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).

Engines used for generators that are utilized as “Prime Power” in place of existing utility power where utility is present or in place of utility power where utility power service does not normally exist.

Failure due to misapplication.

Telephone, cellular phone, facsimile, internet access or other communication expenses.

Living or travel expenses of person(s) performing service , except as specifically included within the terms of a specific unit warranty period.

Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.

Rental equipment used while warranty repairs are being performed.

Overnight freight costs for replacement part(s)

Overtime labor.

Starting batteries, fuses, light bulbs and engine fluids.

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. Purchaser/owner agrees to make no claims against Generac based on negligence.

This warranty gives you specific legal rights.You also may have other rights that vary from state to state.

GENERAC POWER SYSTEMS, INC.

P.O. BOX 297 - WHITEWATER,WI 53190

www.mymowerparts.com

Image 28
Contents Operator’s Manual Manual del Operario Starting WattsCall Generator Helpline Llame Línea Directa del Generador Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Check Battery / Attach Negative Battery WireTo install Electric StartWhen Adding Fuel Before Starting the EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationOperating Generator Starting the EngineConnecting Electrical Loads ReceptaclesStopping the Engine Low Oil Pressure Shutdown System120/240 Volt AC, 30 Amp, Locking Receptacle Ground Fault ProtectionVolt AC, 15 Amp, Gfci Duplex Receptacles Testing the Gfci HOW to USE the Battery ChargerGenerator Adapter Cord SET Creating a Temporary Cold Weather Shelter Cold Weather OperationCreating a Permanent Cold Weather Shelter Power Management Dont Overload GeneratorCapacity ExampleProduct Specifications Generator SpecificationsEngine Specifications Engine Technical InformationGenerator Cleaning Generator MaintenanceGeneral Recommendations Engine Maintenance Battery MaintenanceFuel Valve Maintenance OilService Air Cleaner To clean or replace air cleaner componentsAdding Engine Oil Changing Engine Oil and Oil FilterClean Spark Arrester Screen Clean/Replace Spark PlugClean and inspect the spark arrester as follows Service Adjustments Checking/Adjusting Valve ClearanceCarburetor Adjustments To adjust valve clearanceTighten Jam Nut to 175 inch-pounds 19.7 N-m Storage Long Term Storage InstructionsProtect Fuel System GeneratorTroubleshooting Page Your Warranty Rights and Obligations Emissions Control Warranty Statement Emission Warranty Parts List Warranty is not Transferable This Warranty Shall not Apply to the FollowingLimited Warranty Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tomacorriente Gfci Dobles de 120 Voltios AC, 15 Amp Conozca SU GeneradorTomacorriente con Dispositivo de Seguridad de Montaje Arranque EléctricoDesembalaje del Generador Para instalarAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Tierra del SistemaConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorOperando EL Generador Encienda el MotorSistema DE Parada POR Baja Presion DEL Aceite ReceptáculosConexion De Cargas Electricas Parado Del MotorVolt AC, 15 Amperios, Gfci Receptáculo Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadProtección Contra Fallos de Conexión a Tierra Cargador DE Batería Juego DE Cables DEL Adaptador DEL GeneradorComprobación del Gfci Operación Durante UN Clima Frío Figura 32 Clima Frío Estructura de ProtecciónNo Sobrecargue Generador CapacidadControl de la Energía EjemploInformación Técnica Sobre EL Motor Especificaciones DEL ProductoPeríodo de Cumplimiento del Motor Especificaciones del GeneradorMantenimiento DEL Generador Recomendaciones GeneralesLimpieza del Generador Mantenimiento DEL Motor Advertencia Mantenimiento de la BateríaMantenimiento de la Válvula de Combustible AceiteProporcione Servicio al Depurador de Aire Adición de Aceite del MotorCambio de Aceite del Motor y Filtro de Aceite Para limpiar o sustituir el filtro de aire componentesLimpie la Pantalla Apagachispas Limpie/Reemplace la BujíaLimpie e inspeccione el apagachispas de la siguiente manera Revisiones Y Ajustes Velocidad del MotorAjustes del Carburador Ajuste de la Separación de las VálvulasAlmacenamiento Almacenamiento Para Periodos ProlongadosProteja el Sistema de Combustible GeneradorProblemo Causa Accion Diagnositicos DE AveríasDerechos Y Obligaciones DE LA Garantía Garantía DE Control DE Emisiones EGR Notas Generac Power SYSTEMS, INC Plan DE GarantíaAplicaciones DE CONSUMO/COMERCIALES/INDUSTRIALES Esta Garantía no SE Aplicará EN LOS Siguientes CasosUso del consumidor Uso comercial
Related manuals
Manual 56 pages 3.35 Kb Manual 6 pages 53.09 Kb

30244 specifications

The Briggs & Stratton 30244 is a prominent portable generator designed to meet the power needs of homeowners and professionals alike. This generator stands out for its reliability, efficiency, and user-friendly features, making it a popular choice for a variety of applications, from powering essential appliances during outages to providing electricity at job sites or outdoor events.

One of the main features of the Briggs & Stratton 30244 is its impressive power output. With a maximum wattage of 7000 watts and a rated wattage of 5500 watts, this generator is capable of running multiple appliances simultaneously. Whether you need to power your refrigerator, lights, or other vital equipment during an outage, the 30244 has the capacity to handle it all. This makes it an ideal backup option for homeowners looking to maintain comfort and safety during unexpected blackouts.

The 30244 also boasts advanced technologies designed to enhance performance and fuel efficiency. It is equipped with a powerful and efficient 306cc engine, offering a balance of power and fuel consumption. This generator features a durable, low-oil shutdown system that protects the engine from damage by automatically turning it off when oil levels are low. Additionally, the generator utilizes a large-capacity fuel tank, which allows for extended run times without frequent refueling, making it convenient for prolonged power needs.

Portability is another key characteristic of the Briggs & Stratton 30244. The generator is designed with a compact and sturdy frame, complemented by a built-in handle and durable wheels, enabling easy transportation to wherever the power is needed. Whether you're moving it around the yard or loading it into a vehicle for a camping trip, its lightweight construction and thoughtful design make portability hassle-free.

Safety features are paramount in the Briggs & Stratton 30244, too. It is equipped with circuit breakers to protect against overloads, ensuring safe operation. Additionally, the generator includes a quiet design that minimizes noise, making it suitable for neighborhood use without causing disturbances.

In conclusion, the Briggs & Stratton 30244 is a versatile, powerful, and user-friendly portable generator. Its robust power output, efficient engine technology, portability, and safety features make it an excellent choice for individuals and families seeking reliable power solutions in various situations. Whether for home use or outdoor activities, this generator is designed to deliver performance and peace of mind.