Briggs & Stratton 30204 owner manual When Adding or Draining Fuel, When Starting Equipment

Page 3

5,250 Watt Portable Generator

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT

Do not tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.

3

Image 3
Contents 030204 Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Before Starting the Engine AssemblyGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundConnecting Electrical Loads Operating GeneratorStarting the Engine 120/240 Volt AC, 30 Amp, Locking Receptacle Generator Adapter Cord SETReceptacles Stopping the EnginePower Management Dont Overload GeneratorCapacity Generator Maintenance SpecificationsGeneral Maintenance Recommendations Engine MaintenanceStorage Generator StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingWatt Portable Generator Limited Warranty Advertencia Conserve Estas Instrucciones Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Antes DE Darle Arranque AL Motor MontajeConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorOperando EL Generador Encienda el MotorConexion De Cargas Electricas 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Juego DE Cables DEL Adaptador DEL GeneradorReceptáculos Precaución Parado Del MotorNo Sobrecargue Generador CapacidadControl de la Energía Mantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada

30204 specifications

The Briggs & Stratton 30204 is a powerful and reliable generator, designed to meet the demands of both homeowners and professionals. With a robust 8500 running watts and a max output of 10,000 starting watts, this generator is capable of powering essential appliances, tools, and systems during outages or while on job sites.

One of the standout features of the Briggs & Stratton 30204 is its advanced 2100 Series OHV engine. This engine is engineered for efficiency, providing excellent fuel economy while maintaining high performance. The overhead valve design reduces emissions, making it environmentally friendly while enhancing power output and lifespan.

The generator comes equipped with a durable steel frame, designed to withstand the rigors of outdoor use. It features never-flat wheels for easy transportation, making it portable and suitable for various applications such as camping, outdoor events, and emergency backup during power failures. The control panel is user-friendly, featuring multiple outlets that include 120V 20A household outlets, a 120/240V twist-lock outlet, and a 12V DC outlet for battery charging.

Safety is paramount, and the Briggs & Stratton 30204 incorporates several safety features. It includes a low oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing engine damage. Additionally, its circuit breaker protection ensures that the generator operates safely under load, safeguarding both the generator and connected devices.

Another technological highlight is the IntelliGEN Technology, which adjusts the generator’s output based on the load, ensuring optimal fuel efficiency and performance. This smart management reduces fuel waste and extends the operating time of the generator on a single tank.

Overall, the Briggs & Stratton 30204 is a powerful generator that strikes the perfect balance between performance, efficiency, and durability. Whether for home backup during storms or powering tools on a construction site, this generator is a versatile and dependable choice for anyone in need of reliable electrical power. Its blend of advanced technology and robust construction ensures that it can meet a wide range of power demands, providing peace of mind and convenience.