Briggs & Stratton 30204 owner manual Using the Generator, System Ground, Generator Location

Page 7

5,250 Watt Portable Generator

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Generator Clearance

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 2). Prevailing winds and air currents should be taken into consideration when positioning generator.

Figure 2 — Generator Clearance

Typical Generator Shown

Exhaust Port

7

Image 7
Contents 030204 Safety Rules Table of ContentsEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Before Starting the Engine AssemblyGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundOperating Generator Connecting Electrical LoadsStarting the Engine 120/240 Volt AC, 30 Amp, Locking Receptacle Generator Adapter Cord SETReceptacles Stopping the EngineDont Overload Generator Power ManagementCapacity Generator Maintenance SpecificationsGeneral Maintenance Recommendations Engine MaintenanceGenerator Storage StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingWatt Portable Generator Limited Warranty Advertencia Conserve Estas Instrucciones Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Antes DE Darle Arranque AL Motor MontajeConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Juego DE Cables DEL Adaptador DEL GeneradorReceptáculos Precaución Parado Del MotorCapacidad No Sobrecargue GeneradorControl de la Energía Mantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada

30204 specifications

The Briggs & Stratton 30204 is a powerful and reliable generator, designed to meet the demands of both homeowners and professionals. With a robust 8500 running watts and a max output of 10,000 starting watts, this generator is capable of powering essential appliances, tools, and systems during outages or while on job sites.

One of the standout features of the Briggs & Stratton 30204 is its advanced 2100 Series OHV engine. This engine is engineered for efficiency, providing excellent fuel economy while maintaining high performance. The overhead valve design reduces emissions, making it environmentally friendly while enhancing power output and lifespan.

The generator comes equipped with a durable steel frame, designed to withstand the rigors of outdoor use. It features never-flat wheels for easy transportation, making it portable and suitable for various applications such as camping, outdoor events, and emergency backup during power failures. The control panel is user-friendly, featuring multiple outlets that include 120V 20A household outlets, a 120/240V twist-lock outlet, and a 12V DC outlet for battery charging.

Safety is paramount, and the Briggs & Stratton 30204 incorporates several safety features. It includes a low oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing engine damage. Additionally, its circuit breaker protection ensures that the generator operates safely under load, safeguarding both the generator and connected devices.

Another technological highlight is the IntelliGEN Technology, which adjusts the generator’s output based on the load, ensuring optimal fuel efficiency and performance. This smart management reduces fuel waste and extends the operating time of the generator on a single tank.

Overall, the Briggs & Stratton 30204 is a powerful generator that strikes the perfect balance between performance, efficiency, and durability. Whether for home backup during storms or powering tools on a construction site, this generator is a versatile and dependable choice for anyone in need of reliable electrical power. Its blend of advanced technology and robust construction ensures that it can meet a wide range of power demands, providing peace of mind and convenience.