Briggs & Stratton 30204 Operating Generator, Starting the Engine, Connecting Electrical Loads

Page 8

5,250 Watt Portable Generator

OPERATING THE

GENERATOR

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or to shut down during operation.

2.Turn the fuel valve to the “On” position (Figure 3).The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 3 — Fuel Valve

Fuel Valve is shown in the On position

3.Start engine according to instructions given in the engine owner’s manual.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.

This unit may be equipped with a low oil protection device. See engine manual.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.

Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.

In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3–phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator”.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

8

Image 8
Contents 030204 Equipment Description Table of ContentsSafety Rules When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Before Starting the EngineUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Generator Adapter Cord SET ReceptaclesStopping the Engine 120/240 Volt AC, 30 Amp, Locking ReceptacleCapacity Power ManagementDont Overload Generator Specifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceEngine Storage Other Storage Tips StorageGenerator Storage Troubleshooting Problem Cause CorrectionWatt Portable Generator Limited Warranty Conserve Estas Instrucciones Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Conozca SU Generador Montaje Antes DE Darle Arranque AL MotorUSO DEL Generador Tierra del SistemaUbicación del Generador Conexión al Sistema Eléctrico de un EdificioConexion De Cargas Electricas Operando EL GeneradorEncienda el Motor Juego DE Cables DEL Adaptador DEL Generador Receptáculos PrecauciónParado Del Motor 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadControl de la Energía No Sobrecargue GeneradorCapacidad Especificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorAlmacenamiento Almacenando el GeneradorAlmacenando el Motor Otras Sugerencias Para el AlmacenandoProblemo Accion Causa Diagnositicos DE AveríasGarantía Limitada

30204 specifications

The Briggs & Stratton 30204 is a powerful and reliable generator, designed to meet the demands of both homeowners and professionals. With a robust 8500 running watts and a max output of 10,000 starting watts, this generator is capable of powering essential appliances, tools, and systems during outages or while on job sites.

One of the standout features of the Briggs & Stratton 30204 is its advanced 2100 Series OHV engine. This engine is engineered for efficiency, providing excellent fuel economy while maintaining high performance. The overhead valve design reduces emissions, making it environmentally friendly while enhancing power output and lifespan.

The generator comes equipped with a durable steel frame, designed to withstand the rigors of outdoor use. It features never-flat wheels for easy transportation, making it portable and suitable for various applications such as camping, outdoor events, and emergency backup during power failures. The control panel is user-friendly, featuring multiple outlets that include 120V 20A household outlets, a 120/240V twist-lock outlet, and a 12V DC outlet for battery charging.

Safety is paramount, and the Briggs & Stratton 30204 incorporates several safety features. It includes a low oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing engine damage. Additionally, its circuit breaker protection ensures that the generator operates safely under load, safeguarding both the generator and connected devices.

Another technological highlight is the IntelliGEN Technology, which adjusts the generator’s output based on the load, ensuring optimal fuel efficiency and performance. This smart management reduces fuel waste and extends the operating time of the generator on a single tank.

Overall, the Briggs & Stratton 30204 is a powerful generator that strikes the perfect balance between performance, efficiency, and durability. Whether for home backup during storms or powering tools on a construction site, this generator is a versatile and dependable choice for anyone in need of reliable electrical power. Its blend of advanced technology and robust construction ensures that it can meet a wide range of power demands, providing peace of mind and convenience.