BEFORE STARTING THE ENGINE

Add Fuel

NOTE: This gasoline engine is certified to operate on

gasoline. Exhaust Emission Control System: EM (Engine Modifications).

Add Engine Oil

• Place generator on a level surface.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Refer to engine owner’s manual and follow oil recommendations and instructions.

NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.

NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion (Figure 3).

Figure 3 - Fuel Expansion

 

AirSpace

Tank

 

 

 

Fuel

 

1.5”

 

 

 

 

4.

Install fuel cap and wipe up any spilled fuel.

 

8

Image 8
Contents 030211 6200W Equipment Description Table of ContentsSafety Rules When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine Spark Know Your Generator Assembly Carton ContentsCheck Battery / Attach Negative Battery Wire Electric StartInstall Wheel KIT Refer to and install the wheel kit as followsWhen Adding Fuel Before Starting the EngineAdd Fuel Add Engine OilUsing the Generator Connecting to a Building’s Electrical SystemOperating Generator System GroundConnecting Electrical Loads Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Stopping the EngineBattery Charger Cold Weather OperationPower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Storage Other Storage Tips StorageGenerator Storage Troubleshooting Problem Cause CorrectionSchematic Wiring Diagram Exploded View Main Unit Parts Not Illustrated Exploded View Parts ListDescription Exploded View and Parts List Alternator StatorExploded View and Parts List Control Panel Exploded View and Parts List Wheel KIT WheelLimited Warranty Tabla DE Contenidos Descripción DEL EquipoInstrucciones DE Seguridad AdvertenciaPeligro Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Conozca SU Generador Montaje Arranque EléctricoPara Retirar El Generador De La Caja Contenido de la CajaInstale EL Juego DE Ruedas Instale el Juego de Ruedas Como Sigue FiguraAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Operando EL Generador PrecauciónTierra del Sistema Conexión al Sistema Eléctrico de un EdificioReceptáculos Precaución Conexion De Cargas ElectricasParado Del Motor 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadCargador DE Batería Operación Durante UN Clima FríoNo Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoAlmacenamiento Almacenando el GeneradorAlmacenando el Motor Otras Sugerencias Para el AlmacenandoProblemo Accion Causa Diagnositicos DE AveríasNotas Notas Garantía Limitada