Briggs & Stratton 030209 Receptacles, 120/240 Volt AC, 30 Amp, Locking Receptacle, Hot

Page 10

5500W Portable Generator

RECEPTACLES

CAUTION

Receptacles may be marked with rating value greater than generator output capacity.

NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.

DO NOT overload the generator. See “Don’t Overload Generator”.

120/240 Volt AC, 30 Amp, Locking Receptacle

Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 5).You can use the same 4–wire cord if you plan to run a 120 Volt load.

Figure 5 — 120/240 Volt AC, 30 Amp Receptacle

4-Wire Cord Set

240V

120V 120V

W (Neutral)

Y (Hot)

X (Hot)

NEMA L14-30

Ground (Green)

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,500 watts of power (5.5 kW) at 22.9 Amps for 240 Volts or two independent 120 Volt loads at 20 Amps each.The outlet is protected by push–to–reset circuit breakers.

120 Volt AC, 20 Amp, Duplex Receptacles

Each duplex receptacle (Figure 6) is protected against overload by a push–to–reset circuit breaker.

Figure 6 — 120 Volt, 20 Amp Duplex Receptacle

Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).

10

Image 10
Contents 030209 5500W Safety Rules Table of ContentsEquipment Description When Operating Equipment When Adding or Draining FuelWhen Starting Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Carton Contents AssemblyInstall Wheel KIT Remove Generator From CartonBefore Starting the Engine When Adding FuelInstall fuel cap and wipe up any spilled fuel Add Engine OilSystem Ground Using the GeneratorConnecting to a Building’s Electrical System Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Stopping the EngineVolt AC, 20 Amp, Duplex Receptacles Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle HotCapacity Power ManagementDont Overload Generator ExampleEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage Tips Troubleshooting Problem Cause CorrectionConsumer Use Years Years or YearInstrucciones DE Seguridad Tabla DE ContenidosDescripción DEL Equipo AdvertenciaCuando Opere EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tuerca Mariposa de Conexion a Tierra Conozca SU GeneradorCortacircuitos Tapa del Depósito del Aceite Llene el motor con aceitePara Retirar El Generador De La Caja MontajeInstale EL Juego DE Ruedas Contenido de la CajaAgregue Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Coloque la generador sobre una superficie niveladaUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioConexion De Cargas Electricas Operando EL Generador PrecauciónEncienda el Motor Parado Del MotorVolt AC, 20 Amp, Receptáculos Dobles Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Juego de Cable de 4 Alambres 240V 120V Neutro CargadoControl de la Energía No Sobrecargue GeneradorCapacidad EjemploMantenimiento del Motor EspecificacionesRecomendaciones Generales DE Mantenimiento Para Limpiar el GeneradorAlmacenando el Generador Diagnositicos DE AveríasAlmacenamiento Almacenando el MotorGarantía Limitada

030209 specifications

Briggs & Stratton 030209 is a notable product in the power equipment industry, primarily recognized for its robust and efficient performance. This portable generator is specifically designed to meet the demands of both residential and recreational needs, making it a versatile choice for users.

One of the standout features of the Briggs & Stratton 030209 is its compact and lightweight design. Weighing in at just under 100 pounds, it is easy to transport and store, making it a preferred option for camping trips, tailgating, or emergency backup for power outages. The generator comes equipped with a reliable 2100 watt engine that ensures a consistent power supply, operating quietly while delivering excellent performance.

The generator features a 2.8-gallon fuel tank which allows for extended runtime, providing up to 10 hours of continuous operation at a 25% load. This means that users can rely on the Briggs & Stratton 030209 to keep essential devices running for an extended period without frequent refueling.

Equipped with multiple outlets, including two 120-volt household outlets and one 12-volt DC outlet, the generator accommodates a variety of devices, from small appliances to communication tools and even recreational equipment. Furthermore, it incorporates an advanced inverter technology, which supplies clean and stable power. This is particularly important for sensitive electronics, ensuring they operate safely without the risk of damage.

Safety features are also paramount in the design of the Briggs & Stratton 030209. It includes a low oil shutdown system that automatically turns off the engine to prevent damage when oil levels are low. The generator’s durable construction ensures it can withstand outdoor conditions, while an easy-to-read fuel gauge provides users with quick access to fuel status.

Overall, the Briggs & Stratton 030209 is a reliable and efficient portable generator, perfect for those in need of dependable power in various situations. Its combination of portability, powerful performance, and safety features makes it a top choice among consumers who seek quality and durability in their power equipment.