Briggs & Stratton 030209 owner manual When Adding or Draining Fuel, When Starting Equipment

Page 3

5500W Portable Generator

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground circuit fault interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT

Do not tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.

3

Image 3
Contents 030209 5500W Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Remove Generator From Carton AssemblyInstall Wheel KIT Carton ContentsAdd Engine Oil When Adding FuelInstall fuel cap and wipe up any spilled fuel Before Starting the EngineGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStopping the Engine Connecting Electrical LoadsOperating Generator Starting the EngineHot Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesExample Power ManagementDont Overload Generator CapacityGenerator Maintenance SpecificationsGeneral Maintenance Recommendations Engine MaintenanceStorage Generator StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingYear Consumer Use Years Years orAdvertencia Tabla DE ContenidosDescripción DEL Equipo Instrucciones DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Tapa del Depósito del Aceite Llene el motor con aceite Conozca SU GeneradorCortacircuitos Tuerca Mariposa de Conexion a TierraContenido de la Caja MontajeInstale EL Juego DE Ruedas Para Retirar El Generador De La CajaColoque la generador sobre una superficie nivelada Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorParado Del Motor Operando EL Generador PrecauciónEncienda el Motor Conexion De Cargas ElectricasJuego de Cable de 4 Alambres 240V 120V Neutro Cargado Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 20 Amp, Receptáculos DoblesEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaPara Limpiar el Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorAlmacenando el Motor Diagnositicos DE AveríasAlmacenamiento Almacenando el GeneradorGarantía Limitada

030209 specifications

Briggs & Stratton 030209 is a notable product in the power equipment industry, primarily recognized for its robust and efficient performance. This portable generator is specifically designed to meet the demands of both residential and recreational needs, making it a versatile choice for users.

One of the standout features of the Briggs & Stratton 030209 is its compact and lightweight design. Weighing in at just under 100 pounds, it is easy to transport and store, making it a preferred option for camping trips, tailgating, or emergency backup for power outages. The generator comes equipped with a reliable 2100 watt engine that ensures a consistent power supply, operating quietly while delivering excellent performance.

The generator features a 2.8-gallon fuel tank which allows for extended runtime, providing up to 10 hours of continuous operation at a 25% load. This means that users can rely on the Briggs & Stratton 030209 to keep essential devices running for an extended period without frequent refueling.

Equipped with multiple outlets, including two 120-volt household outlets and one 12-volt DC outlet, the generator accommodates a variety of devices, from small appliances to communication tools and even recreational equipment. Furthermore, it incorporates an advanced inverter technology, which supplies clean and stable power. This is particularly important for sensitive electronics, ensuring they operate safely without the risk of damage.

Safety features are also paramount in the design of the Briggs & Stratton 030209. It includes a low oil shutdown system that automatically turns off the engine to prevent damage when oil levels are low. The generator’s durable construction ensures it can withstand outdoor conditions, while an easy-to-read fuel gauge provides users with quick access to fuel status.

Overall, the Briggs & Stratton 030209 is a reliable and efficient portable generator, perfect for those in need of dependable power in various situations. Its combination of portability, powerful performance, and safety features makes it a top choice among consumers who seek quality and durability in their power equipment.